Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09141MCLAUGHLIN, A C
76X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
2/1/2024
RANGELY
72370
RIO BLANCO  103
SENW 14 2N103W 6
315733View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/20/2005MIT Assigned By:KRABACHER, JAY
Date Recv'd:7/21/2005Facility ID: 150200
DocNum:1170769Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:REPLACE TUBING, 198 jts.
Test Date:6/15/2005
Field Rep:
Approved Date:7/21/2005
Approved by:KRABACHER, JAY
Last Approved MIT:5/9/2002
Injection/Producing Formation Zones:WEBR
Perforation Interval:6369 - 6612
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6246
Top Packer Depth:6160
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE780
5 MIN CASE780
CASE BEFORE0
FINAL CASE780
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE780
No channel test.