| 404483229 | Form 17 | 12/11/2025 | 12/22/2025 | PLUNGER LIFT | 17 | SURGE | GAS | 0 | NO FLOW | 584 | 591 | No | -- | -- | |
| 404291189 | Form 17 | 7/8/2025 | 7/23/2025 | GAS LIFT | 56 | CONTINUOUS | WATER AND GAS | 0 | CONTINUOUS | 577 | 371 | No | -- | -- | Engineering Ad Hoc test. 56 PSI gas and water blew down to 0 PSI in thirty minutes, water observed for entire test, ~2 gal. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly. |
| 404261162 | Form 17 | 6/19/2025 | 6/30/2025 | GAS LIFT | 10 | CONTINUOUS | WATER AND GAS | 1 | WHISPER | 579 | 584 | No | -- | -- | Annual Test. 10 PSI continuous water and gas blew down to 1 PSI within thirty minutes of test. Water observed for entire test, ~1/2 gal of fluid collected. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| 404228377 | Form 17 | 5/21/2025 | 6/4/2025 | GAS LIFT | 75 | CONTINUOUS | WATER AND GAS | 1 | WHISPER | 623 | 627 | No | -- | -- | Engineering Ad Hoc test. 75 PSI water and gas blew down to 1 PSI in thirty minutes, whisper water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly. |
| 403846787 | Form 17 | 6/28/2024 | 7/8/2024 | SHUT-IN | 12 | CONTINUOUS | WATER AND GAS | 0 | NO FLOW | 727 | 727 | No | -- | -- | Annual test. 12 PSI water and gas flow blew down to 0 PSI in 5 minutes. No flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 3/6/2023 | 3/27/2023 | | 1 | Down to Zero | -- | 0 | Down to Zero | 686 | 681 | No | None | None | Annual Test. 1 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
| 403122262 | Form 17 | 7/27/2022 | 8/1/2022 | FLOWING | 12 | DOWN TO 0 | GAS | 0 | NO FLOW | 710 | 710 | No | -- | -- | Re-test after displacement and 70 day build up. Gaseous on open for 10 seconds and died. No flow for remainder of test. Unable to sample due to lack of volume. |
| 402656336 | Form 17 | 4/5/2021 | 4/13/2021 | FLOWING | 215 | CONTINUOUS | MUD | 0 | CONTINUOUS | 971 | 974 | Yes | No | Yes | Test per NTO. Gas for 2 seconds at open. Then non aqueous liquid until 9 minute mark. Turning to non aqueous liquid and water mix until 18 minute mark. Then water for remainder of test. Made 2 gallons total fluid. Did not make enough water for sample. |
| 402607336 | Form 17 | 2/17/2021 | 2/23/2021 | FLOWING | 11 | WHISPER | GAS | 0 | NO FLOW | 148 | 149 | Yes | Yes | No | Test after Date of First Production. Sampled gas then whisper for 6 seconds at open then dead. |
| 402523924 | Form 17 | 10/29/2020 | 11/2/2020 | SHUT-IN | 26 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 0 | Yes | Yes | -- | Test prior to toe prep/ frac. (9 day build up on BH). Down to zero in 90 seconds. Almost undetecable vapor for duration of test. BH sample collected, no production sample available as well is still uncompleted. |
| 402468958 | Form 17 | 8/7/2020 | 8/17/2020 | SHUT-IN | 314 | GAS | -- | 0 | NO FLOW | 0 | 0 | Yes | Yes | -- | Test 60 days after rig release. Drilled uncompleted well. BH gas sample collected. Flow died to vapor at 9 minute mark. No flow detectable by 20 min mark. |