| 404104190 | Form 17 | 2/20/2025 | 2/24/2025 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Pre-P&A. 0 PSI, with no flow observed for 30 minutes. |
| 404071347 | Form 17 | 1/13/2025 | 1/27/2025 | SHUT-IN | 5 | WHISPER | GAS | 0 | NO FLOW | 1350 | 1350 | No | -- | -- | Pre-P&A. 5 PSI blew down to 0 PSI within first five minutes of test. No pressure or flow observed for the remainder of the test. |
| 403674758 | Form 17 | 1/31/2024 | 2/1/2024 | SHUT-IN | 7 | CONTINUOUS | WATER AND GAS | 0 | NO FLOW | 1020 | 1020 | No | -- | -- | Annual test. 7 PSI water and gas flow blew down to 0 PSI in 30 seconds. Intermittent fluid started at 7 minute mark and continued for remainder of test, ~1 quart fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Light | 10/25/2023 | 11/13/2023 | Shut-In | 5 | | -- | 0 | | 330 | 330 | No | No | No | |
| Click for Specifics | Light | 11/16/2022 | 12/19/2022 | Shut-In | 6 | | -- | 0 | | 0 | 0 | No | No | No | |
| Click for Specifics | Light | 10/27/2021 | 11/1/2021 | Shut In | 5 | | -- | 0 | | 473 | 473 | No | No | No | |
| Click for Specifics | Light | 1/29/2020 | 2/17/2020 | | 7 | | -- | 0 | No Flow | 270 | 277 | No | No | No | |
| Click for Specifics | Light | 2/15/2019 | 12/23/2019 | | 23 | | -- | 0 | No Flow | 245 | 269 | No | No | No | |