WELL05-123-27109STROH
12-22
PDC ENERGY INC
69175
TA
3/11/2021
WATTENBERG
90750
WELD  123
SWNW 22 4N67W 6
310848
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 654 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404263743Form 176/10/20257/1/2025SHUT-IN58CONTINUOUS GAS2 CONTINUOUS 00No----Remediation follow up test. 58 PSI continuous gas flow blew down to 2 PSI within thirty minutes. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403840949Form 176/20/20246/30/2024 42DOWN TO 0 WATER AND GAS0 CONTINUOUS 00No----emediation follow up test. 42 PSI blew down to 0 PSI within first five minutes of test, continuous water throughout entire test. PDC will schedule a sampling event and sumbit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403448515Form 176/26/20236/28/2023SHUT-IN12CONTINUOUS WATER AND GAS0 CONTINUOUS 00No----Abatement system follow up test. 12 PSI gas and water on open. Steady stream of black liquid for entire test, ~15 gallons total. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403356362Form 173/24/20233/27/2023SHUT-IN53CONTINUOUS GAS3 CONTINUOUS 00Yes----Annual test. 53 PSI continuous gas flow blew down to 3 PSI in 30 minutes. Gas sample collected 2/2023. PDC will continue to monitor monthly.
403307015Form 1710/18/20221/31/2023SHUT-IN51CONTINUOUS GAS0 CONTINUOUS 00Yes----Follow-Up test. 51 PSI gas flow blew down to 0 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. This test had delayed submission due to systems error.
402992306Form 173/18/20223/22/2022SHUT-IN54CONTINUOUS GAS0 WHISPER 11YesYes--Test per NTO. Gas on open, collected BH gas sample. Down to zero in 2 minutes, whisper after 7 minutes and for duration of test.
402643973Form 173/29/20213/30/2021SHUT-IN14CONTINUOUS GAS0 NO FLOW 00No----Test per NTO. Gas on oepn, down to zero in 20 seconds. Dead @ 8 minute mark, no flow for remainder of test.
Click for SpecificsLight8/12/20208/18/2020 2 --0No Flow12351235NoNoNo 
402248012Form 1711/15/201911/25/2019SHUT-IN5DOWN TO 0 --0 NO FLOW 967967No----Test per NTO. Blew dead < 1 min. BH dead