Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-17902DINNER E UNIT
1
PDC ENERGY INC
69175
SI
6/1/2025
WATTENBERG
90750
WELD  123
SWSE 14 4N66W 6
332746
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 385 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404083057Form 171/24/20252/5/2025SHUT-IN20DOWN TO 0 WATER AND GAS0 CONTINUOUS 00No----Annual Test. 20 PSI gas and water blew down to 0 PSI within first minute of test, water continued to slowly drip throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403684205Form 172/7/20242/12/2024SHUT-IN9CONTINUOUS WATER AND GAS0 DOWN TO 0 750750No----Annual test. 9 PSI water and gas flow blew down to 0 PSI in 30 seconds, intermittent fluid started at 9 minute mark and lasted for remainder of the test, ~1/2 gallon total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403301006Form 171/11/20231/25/2023SHUT-IN11DOWN TO 0 WATER AND GAS0 CONTINUOUS 680680No----Annual Test. 11 PSI gas and water blew down to 0 PSI within first minute of test. 1 quart water at open then steady drip for remainder of test. PDC will continue to monitor monthly.
403218552Form 1711/2/202211/3/2022SHUT-IN2DOWN TO 0 WATER AND GAS0 NO FLOW 00No----Annual Test. 2 PSI water and gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsFull7/31/202111/1/2021 20Down to Zero--0No Flow400400NoNoneNone 
Click for SpecificsLight9/20/202012/3/2020 14 --0No Flow375375NoNoNo 
402294385Form 171/17/20201/24/2020FLOWING19DOWN TO 0 --0 NO FLOW 297278No----Short surface casing. Annual. 19 psig initial surface casing pressure. Down to 0 psig within 5 minutes. No samples taken.
Click for SpecificsFull11/12/201912/24/2019 18Down To Zero---- 348--NoNoNoShort surface casing. Below bradenhead threshold. No mitigation or Form 4 required.