Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10254Schaefer LD
13-032HC
PDC ENERGY INC
69175
PR
10/1/2022
WATTENBERG
90750
ADAMS  001
SWSE 24 1S67W 6
440718
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1784 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404098675Form 172/4/20252/18/2025PLUNGER LIFT71CONTINUOUS GAS1 WHISPER 508507No----Engineering Ad Hoc test. 71 PSI gas blew down to 1 PSI in thirty minutes. Gas present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403911317Form 179/4/20249/5/2024 51DOWN TO 0 GAS0 NO FLOW 503502No----Engineering Ad Hoc test. 51 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull4/15/20244/16/2024 29Down to Zero--0Down to Zero693700NoNoNoAnnual Test.  29 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403687129Form 172/13/20242/14/2024SHUT-IN53CONTINUOUS GAS0 NO FLOW 461461No----Automation Alert follow-up test. 53 PSI gas blew down to whisper in 90 seconds, whisper lasted until 4 minute mark. No flow or pressure for the remainder of the test. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/14/20234/24/2023 40Down to Zero--0Down to Zero682681NoNoneNoneAnnual Test. 40 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsFull10/11/202211/8/2022Shut-In35Down to Zero--0Down to Zero396396NoNoneNone 
402839859Form 179/30/202110/13/2021FLOWING46DOWN TO 0 GAS0 NO FLOW 10421049No----Retest after blowdown period and build up since 9/16/2021. Gas for 13 seconds at open then dead for remainder of test.
402656478Form 174/6/20214/13/2021FLOWING71CONTINUOUS GAS0 NO FLOW 970972YesYesNoTest per NTO. Gas at open. Sampled then gas slowing to dead at 7 minute mark. Dead for remainder of test.
402523095Form 1710/28/202010/30/2020FLOWING10GAS --0 NO FLOW 10421041No----6 month retest. Gas for 20 seconds at open then dead.
402388328Form 175/1/20205/4/2020FLOWING6GAS --0 NO FLOW 2929No----Test after displacment and 40 day build up. Gas for 13 seconds then dead.
402248355Form 1711/21/201911/25/2019FLOWING594CONTINUOUS --0 CONTINUOUS 15221522No----Test per NTO. Blew down through 2" line to frac tank. Continuous gas through test till 28 min mark. Then blew to a whisper. 0 psi and whisper on shut.
402084385Form 176/14/20196/21/2019SHUT-IN0NO FLOW --0 NO FLOW 15941595No----Test after DOFP. Bradenhead dead. Well was turned back on at the 20 minute mark.
401967698Form 173/7/20193/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac.