Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10132Sharp
2635-1-15HC
PDC ENERGY INC
69175
PR
10/18/2018
WATTENBERG
90750
ADAMS  001
SWSW 24 1S67W 6
436062
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1740 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/4/202511/5/2025 19Continuous--0No Flow368370NoNoNo Annual Test.  19 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/5/20255/13/2025 10Continuous--0No Flow330332NoNoNoAnnual Test.  10 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/15/20244/16/2024 4Down to Zero--0Down to Zero432435NoNoNoAnnual Test.  4 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/31/20234/10/2023 8Down to Zero--0Down to Zero492492NoNoneNoneAnnual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
403256818Form 1712/8/202212/12/2022PLUNGER LIFT72CONTINUOUS WATER AND GAS0 CONTINUOUS 430432Yes----Automation Alert follow-up test. 72 PSI gas and water flow blew down to 0 PSI in 5 minutes through 1/2" needle valve. Water continued for the entire test, 1/2 gallon total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull10/10/202211/8/2022Plunger Lift29Down to Zero--0Down to Zero418420NoNoneNone 
402844906Form 1710/15/202110/18/2021PLUNGER LIFT21DOWN TO 0 GAS0 NO FLOW 455455No----Test after displacement and 63 day build up. Gas no open for 40 seconds and died. No flow for remainder of test.
402687854Form 175/5/20215/13/2021FLOWING72CONTINUOUS WATER H200 CONTINUOUS 536534YesNoYesTest per NTO. Water at open. Slowing to drips by 1 minute. Drips for remainder of test. Made 3/4 of a gallon total.
402523097Form 1710/28/202010/30/2020FLOWING1GAS --0 NO FLOW 647648No----6 month retest. Gas for 20 seconds at open then dead.
402394039Form 175/8/20205/8/2020FLOWING8GAS --0 NO FLOW 874868No----Test after displacement and 22 day build up. Gas for 30 seconds then dead.
402306705Form 171/28/20202/7/2020FLOWING188WATER H20 --0 WATER H20 10991100Yes--YesTest after 5 week blowdown and 12 day buildup. 1980 mL water sample taken. BH down to trickle after sample collection. Made ~2 gallons total including sample.
402147711Form 178/16/20198/16/2019FLOWING143CONTINUOUS --0 NO FLOW 17871787YesYes--Test per NTO. BH had 143 psi on open. Took 110ml samples from BH and CSG. Blew dead in 1 minute. BH dead.
401853681Form 1711/1/201811/28/2018FLOWING2WHISPER --0 NO FLOW 22722272No----Test taken after DOFP. Blew down to whisper in <1 minute. Died after 2 minutes.
401787023Form 179/21/201810/8/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----Test taken before Toe Prep.