Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-51457Bost Farm
38C-8-L
PDC ENERGY INC
69175
PR
11/13/2022
WATTENBERG
90750
GREELEY/WELD  123
Lot2 7 5N66W 6
456832
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1699 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404400470Form 1710/14/202510/22/2025PLUNGER LIFT18DOWN TO 0 GAS0 NO FLOW 510509No----Remediation follow up test. 18 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404043743Form 1712/11/202412/31/2024PLUNGER LIFT14DOWN TO 0 GAS0 NO FLOW 654655No----Remediation follow up test. 14 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/15/202410/22/2024 15Continuous--0No Flow722721NoNoNoAnnual Test.  15 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull11/1/202311/13/2023Flowing10Down to Zero--0No Flow10441042NoNoNoAnnual Test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403256688Form 1712/8/202212/12/2022FLOWING53DOWN TO 0 WATER H200 CONTINUOUS 22902290Yes----30 days of first sales - high pressure follow-up. 53 PSI water on open, produced 1 quart and died for several minutes. Water drips started again shortly after 5 minute mark. Collected 1000mL water sample. Water drip for duration of test, produced ~ 1/2 gallon of water total. PDC will monitor pressure and re-test according to bradenhead policy.
403076351Form 176/10/20226/13/2022SHUT-IN0NO FLOW --0 NO FLOW 00No----Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy.