View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404408193Form 1710/15/202510/27/2025PLUNGER LIFT109DOWN TO 0 WATER H202 CONTINUOUS 565582No----Remediation follow up test. 109 PSI gas and water, blew down to 2 PSI in thirty minutes, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403960748Form 1710/14/202410/17/2024PLUNGER LIFT41CONTINUOUS GAS0 NO FLOW 695696No----Remediation follow up test. 41 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403802432Form 175/17/20245/23/2024 74CONTINUOUS WATER H202 CONTINUOUS 742740No----Engineering Ad Hoc test. 74 PSI continuous water blew down to 2 PSI in thirty minutes. PDC will continue to monitor monthly.
Click for SpecificsFull12/13/202312/18/2023Flowing0Down to Zero--0Down to Zero864883NoNoNoAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy.
403256644Form 1712/6/202212/12/2022FLOWING75DOWN TO 0 GAS0 NO FLOW 16691664Yes----30 days of first sales - high pressure follow-up. 75 PSI gas flow blew down to 0 PSI within 5 minutes, no flow or pressure for remainder of the test. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403076362Form 176/10/20226/13/2022SHUT-IN0NO FLOW --0 NO FLOW 00No----Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy.