| 404423371 | Form 17 | 10/28/2025 | 11/4/2025 | PLUNGER LIFT | 4 | CONTINUOUS | GAS | 0 | NO FLOW | 311 | 308 | No | -- | -- | Annual Test. 4 PSI blew down to 0 PSI within 15 minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Light | 10/20/2024 | 10/22/2024 | | 1 | | -- | 0 | | 350 | 352 | No | No | No | |
| 403620128 | Form 17 | 12/8/2023 | 12/11/2023 | SHUT-IN | 2 | CONTINUOUS | GAS | 0 | NO FLOW | 631 | 631 | No | -- | -- | Annual Test. 2 PSI blew down to 0 PSI within first 8 minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403037495 | Form 17 | 2/27/2022 | 5/4/2022 | PLUNGER LIFT | 5 | CONTINUOUS | VAPOR | 0 | NO FLOW | 590 | 590 | No | -- | -- | Engineering Ad Hoc test, 5 PSI vapor blew down to 0 PSI after 20 minutes of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
| 403037485 | Form 17 | 2/9/2022 | 5/4/2022 | FLOWING | 7 | DOWN TO 0 | VAPOR | 2 | WHISPER | 745 | 745 | Yes | -- | -- | Annual Test, 7 PSI slight vapor blew down to 2 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 8/18/2021 | 11/1/2021 | | 0 | No Flow | -- | 0 | No Flow | 290 | 312 | No | None | None | |
| Click for Specifics | Light | 9/17/2020 | 12/3/2020 | | 15 | | -- | 0 | No Flow | 963 | 963 | No | No | No | |
| 402054938 | Form 17 | 5/20/2019 | 5/24/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 2542 | 2542 | No | -- | -- | No fluid, no gas, no vapor. |
| 401909448 | Form 17 | 1/16/2019 | 1/17/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | -- | -- | No | -- | -- | No fluid, gas or vapors. |