Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-47370Postle IC
09-182HC
PDC ENERGY INC
69175
PR
7/1/2025
WATTENBERG
90750
MEAD/WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1552 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404325993Form 178/5/20258/21/2025GAS LIFT10CONTINUOUS GAS0 NO FLOW 545544No----Remediation follow up test. 10 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404098621Form 172/6/20252/18/2025FLOWING355CONTINUOUS GAS AND LIQUID HYDROCARBON1 WHISPER 400401No----Engineering Ad Hoc test. 355 PSI gas and liquid hydrocarbon blew down to 1 PSI in thirty minutes. Gas and oil substance present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403911895Form 179/5/20249/6/2024SHUT-IN360CONTINUOUS WATER AND GAS5 CONTINUOUS 426426No----Ad hoc test. 360 PSI strong gas and water for 5 minutes, steady fluid trickle for remainder of test, blew down to 5 PSI in 30 minutes. ~15 gallons black fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403779917Form 174/24/20245/6/2024PLUNGER LIFT213CONTINUOUS MUD AND GAS0 DOWN TO 0 436430Yes----Ad hoc test. 213 PSI gas and mud produced ~4 gallons in the first 3 minutes of test and trickled fluid with surging gas until 6 minute mark. No flow or pressure until light fluid trickle began at 22 minute mark and lasted until 27 minute mark. ~4.5 gallons total fluid, mud, water, and liquid hydrocarbons produced during test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/6/20233/27/2023 0Down to Zero--0Down to Zero557556NoNoneNoneAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly.
Click for SpecificsFull11/22/202211/29/2022 0Down to Zero--0Down to Zero653653NoNoneNone 
402598239Form 172/9/20212/11/2021FLOWING0WHISPER GAS0 NO FLOW 1111No----Test after DOFP. Whisper on open for 25 seconds and died. No flow for the remainder of the test.
402527083Form 1711/3/202011/6/2020SHUT-IN1WHISPER GAS0 NO FLOW 00No----Test prior to toe prep/frac. Whisper on open, died in 30 seconds.
402468972Form 178/7/20208/17/2020SHUT-IN0WHISPER --0 NO FLOW 00No----Test 60 days after rig release. Drilled uncompleted well. Slight whisper on open then dead.