Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46697J Clark
9C
PDC ENERGY INC
69175
PR
3/1/2025
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1677 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404554651Form 172/11/20262/23/2026PLUNGER LIFT40DOWN TO 0 WATER AND GAS0 CONTINUOUS 286289No---- 
404129157Form 172/27/20253/14/2025SHUT-IN41CONTINUOUS WATER AND GAS1 CONTINUOUS 400400No----Remediation follow up test. 41 PSI continuous gas and water flow blew down to 1 PSI within thirty minutes. Gas and water observed throughout the entire test, ~5 gals. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403728715Form 173/18/20243/22/2024PLUNGER LIFT37DOWN TO 0 WATER AND GAS0 CONTINUOUS 330332No----Annual test. 37 PSI water and gas flow blew down to 0 PSI in seconds, water continued to drip for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403350597Form 173/13/20233/20/2023PLUNGER LIFT22DOWN TO 0 WATER AND GAS0 CONTINUOUS 312320No----Annual Test. 22 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Water trickled the entire test. PDC will continue to monitor monthly.
403216558Form 1711/1/202211/2/2022PLUNGER LIFT41DOWN TO 0 WATER AND GAS0 NO FLOW 275274No----Abatement system follow up test. 41 PSI water and gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402984454Form 173/14/20223/15/2022PLUNGER LIFT62CONTINUOUS WATER AND GAS0 CONTINUOUS 262262Yes----Annual Test, 62 PSI slight gas, continuous water flow blew down to 0 PSI within 30 minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402816079Form 179/15/20219/20/2021PLUNGER LIFT33CONTINUOUS WATER H200 NO FLOW 368370No----Abatement system follow up test, 33 PSI water flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402670325Form 174/19/20214/26/2021 76CONTINUOUS WATER H200 NO FLOW 463460Yes----Annual Test 76 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402769825Form 179/22/20208/4/2021FLOWING12DOWN TO 0 --0 NO FLOW 441441No----Abatement system follow up test, 12 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402448538Form 174/28/20207/22/2020 117WATER H20 --20 WATER H20 521525No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402440427Form 173/31/20207/9/2020 891GAS --0 WHISPER 759759Yes----Annual Test 891 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402236661Form 1711/7/201911/12/2019FLOWING84GAS --8 WHISPER 724724YesYes--Annual Test 84 PSI slight gas flow blew down to a whisper for the entire 30 min test. 8 PI at the end of the test. PDC has collected a sample and will submit via form 43 when results are available. PDC will submit a remediation plan vi sundry.