WELL05-123-46688J Clark
1C
PDC ENERGY INC
69175
PR
12/1/2025
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1678 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404323696Form 178/1/20258/20/2025SHUT-IN18DOWN TO 0 GAS0 CONTINUOUS 480480No----Remediation follow up test. 18 PSI gas and water, blew down to 0 within first few seconds, whisper gas and trickle water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404129124Form 172/26/20253/14/2025SHUT-IN71CONTINUOUS WATER AND GAS5 CONTINUOUS 484484No----Engineering Ad Hoc test. 71 PSI gas and water blew down to 1 PSI in thirty minutes. Gas and water observed throughout entire test, ~25 gals. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
404098484Form 172/5/20252/18/2025SHUT-IN71CONTINUOUS GAS AND LIQUID HYDROCARBON5 CONTINUOUS 478478No----Engineering Ad Hoc test. 71 PSI gas and liquid hydrocarbon blew down to 5 PSI in thirty minutes. Gas and liquid hydrocarbon present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly
Click for SpecificsFull3/8/20244/1/2024 0No Flow--0No Flow268264NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/17/20233/27/2023 0No Flow--0No Flow264262NoNoneNoneAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly.
Click for SpecificsFull3/14/20224/18/2022 0Down to Zero--0Down to Zero350350NoNoNo 
Click for SpecificsFull4/12/202111/1/2021 0Whisper (very low flow)--0No Flow629646NoNoneNone 
Click for SpecificsLight4/27/20205/11/2020 25 --25 768768NoNoNo 
Click for SpecificsLight10/20/20198/18/2020 40 --0 986986NoNoNo