404004335 | Form 17 | 11/20/2024 | 11/25/2024 | FLOWING | 19 | DOWN TO 0 | GAS | 0 | NO FLOW | 474 | 474 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc# 403120623 |
403601095 | Form 17 | 11/13/2023 | 11/20/2023 | PLUNGER LIFT | 24 | DOWN TO 0 | GAS | 0 | NO FLOW | 530 | 531 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc# 403120623
Initial pressure blew down all gas in ~30 seconds. Surge flow beginning at 4 minutes into test brought up ~1 quart of fluid over 4-5 minutes. No further fluid after ~8 minutes into test. |
403213904 | Form 17 | 10/27/2022 | 11/3/2022 | FLOWING | 62 | CONTINUOUS | WATER AND GAS | 0 | CONTINUOUS | 489 | 489 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc# 403120623 |
403060954 | Form 17 | 5/18/2022 | 5/26/2022 | FLOWING | 41 | DOWN TO 0 | WATER H20 | 0 | NO FLOW | 580 | 579 | No | -- | -- | Mitigation Bradenhead Test
WBD attached |
Click for Specifics | Full | 1/11/2022 | 2/21/2022 | Plunger Lift | 23 | Down to Zero | Water and Gas | 0 | No Flow | 507 | 504 | Yes | No | Yes | |
402893017 | Form 17 | 11/23/2021 | 12/8/2021 | FLOWING | 67 | DOWN TO 0 | WATER AND GAS | 0 | NO FLOW | 528 | 531 | Yes | Yes | No | Form 17 submitted to update doc # 402880537 which reported gas and liquid samples Only a gas sample was collected on 11/23/2021. |
402880537 | Form 17 | 11/23/2021 | 11/29/2021 | FLOWING | 67 | DOWN TO 0 | WATER AND GAS | 0 | NO FLOW | 528 | 531 | Yes | Yes | Yes | |
Click for Specifics | Full | 1/26/2021 | 2/16/2021 | | 7 | DOWN TO 0 | -- | 0 | NO FLOW | 701 | 711 | No | No | No | Surface casing pressure blew down to 0 psi in 10 seconds, produced only gas.
|
Click for Specifics | Full | 2/24/2020 | 3/23/2020 | | 24 | DOWN TO 0 | -- | 0 | NO FLOW | 1058 | 1057 | No | No | No | Surface casing pressure blew down to 0 psi in 30 seconds, produced only gas. |
402027156 | Form 17 | 4/25/2019 | 4/30/2019 | FLOWING | 75 | DOWN TO 0 | -- | 0 | NO FLOW | 1829 | 1862 | Yes | Yes | No | Surface casing blew down to 0 in 1 minute 20 seconds, produced gas at the start, then produced an oil/water mix. Insufficient volume of fluid to sample and test. Gas was sampled. |
401781181 | Form 17 | 10/2/2018 | 10/2/2018 | FLOWING | 1 | DOWN TO 0 | -- | 0 | NO FLOW | 2812 | 2812 | No | -- | -- | blew down surface casing from 1 to 0 in about 10 seconds. no fluid or issues. |