Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45451Wilson IC
03-302HC
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1591 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404413631Form 1710/22/202510/29/2025PLUNGER LIFT76DOWN TO 0 WATER AND GAS0 CONTINUOUS 400401No----Remediation follow up test. 76 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404220287Form 175/21/20255/28/2025PLUNGER LIFT96CONTINUOUS WATER H200 NO FLOW 369383No----Annual Test. 96 PSI blew down to 0 PSI within twenty minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403985513Form 1710/30/202411/6/2024 5DOWN TO 0 GAS0 NO FLOW 533498No----Remediation follow up test. 5 PSI whisper blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403807818Form 175/21/20245/30/2024SHUT-IN52CONTINUOUS GAS AND LIQUID HYDROCARBON0 WHISPER 462462No----Annual test. 52 PSI blew down to 0 PSI in 12 seconds. Intermittent fluid and gas for entire test. Fluid quantity insufficient to sample at this time. PDC will monitor pressure and re-test according to bradenhead policy.
403807239Form 175/21/20245/30/2024 52CONTINUOUS GAS AND LIQUID HYDROCARBON0 WHISPER 462462No----Annual test. 52 PSI liquid and gas flow blew down to 0 PSI in seconds. Initial continuous flow of liquid and gas, whisper of gas and trickling liquid at random for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/25/20236/5/2023Plunger Lift6Down to Zero--0No Flow394393NoNoneNone 
403371163Form 174/4/20234/12/2023PLUNGER LIFT85DOWN TO 0 WATER H200 CONTINUOUS 486486Yes--YesAutomation Alert follow-up test. 85 PSI water on open, produced 250mL and died to trickle/drip. Trickle/drip for entire test, produced ~2000mL total. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/16/20229/6/2022 5Down to Zero--0Down to Zero544544NoNoneNone 
402807225Form 179/2/20219/10/2021PLUNGER LIFT7WHISPER GAS0 NO FLOW 558560No----Test after displacement and 80 day buildup. Whisper on open for 40 seconds and died. No flow for remainder of test.
402705099Form 175/26/20216/1/2021FLOWING186CONTINUOUS WATER H200 CONTINUOUS 623624YesNoYesTest per NTO. Water at open. Water continuing for entire test. Made 2.5 gallons total.
402547010Form 1711/25/202012/4/2020PLUNGER LIFT10WHISPER GAS0 NO FLOW 737745No----Test per 2020 NTO. Whisper on open for 30 seconds and died. No flow for the remainder of the test.
402255870Form 1712/4/201912/5/2019SHUT-IN0NO FLOW --0 NO FLOW 18401856No----Test after DOFP. Vacuum on open, died instantly. Well turned on at ~25 minute mark.
402071292Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac.