Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45432Wilson IC
03-022HC
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1530 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404326163Form 178/5/20258/21/2025PLUNGER LIFT12CONTINUOUS WATER H200 NO FLOW 447447No----Remediation follow up test. 12 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404220375Form 175/21/20255/28/2025PLUNGER LIFT85CONTINUOUS LIQUID HYDROCARBON0 NO FLOW 505506No----Annual Test. 85 PSI blew down to 0 PSI within five minutes. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403815729Form 176/5/20246/6/2024INJECTION52WHISPER GAS AND LIQUID HYDROCARBON0 WHISPER 542541No----Annual test. 52 PSI gas and fluid flow blew down to 0 PSI in 5 minutes, light fluid for remainder of test, ~0.5 gallons total. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/20/20245/30/2024 0Down to Zero--0Down to Zero498498NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/5/20236/12/2023 22Down to Zero--0No Flow559558NoNoNoAnnual Test. 22 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/16/20229/6/2022 12Down to Zero--0Down to Zero551551NoNoneNone 
402805372Form 179/2/20219/8/2021PLUNGER LIFT18DOWN TO 0 GAS0 NO FLOW 884884No----Test after displacement and 78 day buildup. Gas on open for 1 minute and died. No flow for remainder of test.
402704988Form 175/25/20216/1/2021FLOWING119CONTINUOUS MUD0 CONTINUOUS 970961YesNoYesTest per NTO. Non aqueous fluid at open. Sampled fluid. Down to intermitent drips and trickles by 5 minute mark. Made 1 gallon total.
402546783Form 1711/25/202012/4/2020PLUNGER LIFT16CONTINUOUS GAS0 NO FLOW 962959No----Test per 2020 NTO. Gas on open for 40 seconds and died. No flow for the remainder of the test.
402255679Form 1712/4/201912/5/2019FLOWING0NO FLOW --0 NO FLOW 890909No----Test per NTO. BH dead.
401809582Form 1710/24/201810/26/2018FLOWING227WATER H20 --0 WATER H20 19071909No----Test taken after DOFP. Made 3 gallons of brownish/black liquid during blowdown. Switched to clear liquid trickle after blowdown.