WELL05-123-44087Bunting
26Q-212
PDC ENERGY INC
69175
PR
4/7/2019
WATTENBERG
90750
WELD  123
SWSE 26 5N65W 6
448963
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1669 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull7/31/20248/6/2024 0No Flow--0No Flow313312NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull9/19/20239/25/2023Plunger Lift0Down to Zero--0Down to Zero348347NoNoNoAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull9/6/202210/10/2022 5Down to Zero--0No Flow350350NoNoneNone 
Click for SpecificsFull4/16/202111/1/2021 0Gas--0No Flow499493NoNoneNone 
402423941Form 174/11/20206/16/2020 2WATER H20 --0 NO FLOW 764763No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
Click for SpecificsLight3/29/20205/11/2020 9 --9 780780NoNoNo 
402034290Form 174/26/20195/7/2019FLOWING78DOWN TO 0 --0 NO FLOW 21152115No----78 PSI blew down to 0 PSI instantly, no flow or pressure for the remainder of bradenhead test. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure.
401613078Form 174/12/20184/18/2018SHUT-IN20DOWN TO 0 --0 NO FLOW 00No----Post TD test 20 PSI blew down to 0 instantly no flow or pressure for remainder of test