WELL05-123-41634R&R Farms
29I-401
PDC ENERGY INC
69175
SI
11/1/2025
WATTENBERG
90750
WELD  123
SWSW 29 5N63W 6
442014
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 911 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404236123Form 175/28/20256/10/2025SHUT-IN107DOWN TO 0 GAS0 NO FLOW 294296No----Remediation follow up test. 107 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403823225Form 176/6/20246/12/2024 46DOWN TO 0 GAS0 NO FLOW 241234No----Remediation follow up test. 46 PSI blew down to 0 PSI within first five minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/19/20236/28/2023 0Down to Zero--0Down to Zero403403NoNoNo 
403147189Form 178/24/20228/25/2022SHUT-IN52CONTINUOUS GAS0 NO FLOW 402405Yes----Annual Test, 52 PSI whisper gas blew down to 0 PSI in 20 minutes. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402787536Form 175/30/20218/23/2021SHUT-IN1DOWN TO 0 --0 NO FLOW 179179No----Annual Test, 1 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsLight4/20/20205/11/2020 32 --32 195195NoNoNo 
402420210Form 174/4/20206/12/2020 28GAS --0 NO FLOW 196196No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402114217Form 176/25/20197/18/2019FLOWING155GAS --0 NO FLOW 227227No----Annual Test, 155 PSI blew down to 0 PSI after one minute. No pressure or flow observed for the duration of the 30 min test. PDC will attempt to collect a sample and submit to COGCC via form 43. PDC has submitted a remediation plan via sundry