| 404236123 | Form 17 | 5/28/2025 | 6/10/2025 | SHUT-IN | 107 | DOWN TO 0 | GAS | 0 | NO FLOW | 294 | 296 | No | -- | -- | Remediation follow up test. 107 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403823225 | Form 17 | 6/6/2024 | 6/12/2024 | | 46 | DOWN TO 0 | GAS | 0 | NO FLOW | 241 | 234 | No | -- | -- | Remediation follow up test. 46 PSI blew down to 0 PSI within first five minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
|
| Click for Specifics | Full | 6/19/2023 | 6/28/2023 | | 0 | Down to Zero | -- | 0 | Down to Zero | 403 | 403 | No | No | No | |
| 403147189 | Form 17 | 8/24/2022 | 8/25/2022 | SHUT-IN | 52 | CONTINUOUS | GAS | 0 | NO FLOW | 402 | 405 | Yes | -- | -- | Annual Test, 52 PSI whisper gas blew down to 0 PSI in 20 minutes. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
| 402787536 | Form 17 | 5/30/2021 | 8/23/2021 | SHUT-IN | 1 | DOWN TO 0 | -- | 0 | NO FLOW | 179 | 179 | No | -- | -- | Annual Test, 1 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
| Click for Specifics | Light | 4/20/2020 | 5/11/2020 | | 32 | | -- | 32 | | 195 | 195 | No | No | No | |
| 402420210 | Form 17 | 4/4/2020 | 6/12/2020 | | 28 | GAS | -- | 0 | NO FLOW | 196 | 196 | No | -- | -- | 6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC. |
| 402114217 | Form 17 | 6/25/2019 | 7/18/2019 | FLOWING | 155 | GAS | -- | 0 | NO FLOW | 227 | 227 | No | -- | -- | Annual Test, 155 PSI blew down to 0 PSI after one minute. No pressure or flow observed for the duration of the 30 min test. PDC will attempt to collect a sample and submit to COGCC via form 43. PDC has submitted a remediation plan via sundry |