Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-39386KODAK NORTH FD
25-040HC
PDC ENERGY INC
69175
PR
2/1/2025
WATTENBERG
90750
WELD  123
SENW 26 6N67W 6
333035
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1524 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404550862Form 172/11/20262/19/2026PLUNGER LIFT58CONTINUOUS WATER H200 NO FLOW 355354No---- 
404384695Form 1710/2/202510/8/2025PLUNGER LIFT11CONTINUOUS GAS0 NO FLOW 611608No----Remediation follow up test. 11 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404147546Form 173/19/20253/31/2025PLUNGER LIFT10DOWN TO 0 GAS0 NO FLOW 554548No----Remediation follow up test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull1/21/20251/28/2025 6Down to Zero--0No Flow423423NoNoNoAnnual Test.  6 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull2/13/20242/26/2024Gas Lift2Down to Zero--0Down to Zero357359NoNoNoAnnual Test.  2 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/20/20235/1/2023 6Down to Zero--0Down to Zero533539NoNoneNoneAnnual Test. 6 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsFull10/4/202211/8/2022Plunger Lift48Down to Zero--0Down to Zero595595NoNoneNone 
402780627Form 178/12/20218/15/2021FLOWING7CONTINUOUS GAS0 NO FLOW 757757No----Retest after build up since displacement on 3/31/2021. Gas for 45 seconds then dead.
402646895Form 173/23/20214/2/2021FLOWING53CONTINUOUS WATER H200 CONTINUOUS 846847YesNoYesTest per NTO. Water at open. Down to drips at 2 minute mark for remainder of test. Made just enough for sample.
402357626Form 173/25/20203/31/2020FLOWING2WHISPER --0 NO FLOW 996996No----Test after DOFP. Whisper on open, died in 5 seconds.
402283389Form 171/8/20201/13/2020SHUT-IN2DOWN TO 0 --0 NO FLOW 00No----Test prior to toe-prep/frac.