| 404318933 | Form 17 | 7/22/2025 | 8/15/2025 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Remediation follow up test. 0 PSI, no pressure or flow observed. Operator will monitor pressure and re-test according to bradenhead policy. |
| 404291118 | Form 17 | 7/7/2025 | 7/23/2025 | SHUT-IN | 25 | CONTINUOUS | WATER H20 | 0 | CONTINUOUS | 700 | 700 | No | -- | -- | Pre-P&A. 25 PSI continuous water flow blew down to 0 PSI within thirty minutes. |
| 404233576 | Form 17 | 6/3/2025 | 6/9/2025 | SHUT-IN | 33 | CONTINUOUS | WATER AND GAS | 1 | WHISPER | 733 | 733 | No | -- | -- | Annual Test. 33 PSI water and gas blew down to 1 PSI within thirty minutes of test. Water observed for entire test, ~7 gals of fluid collected. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| 404082905 | Form 17 | 2/17/2025 | 2/5/2025 | SHUT-IN | 35 | CONTINUOUS | WATER AND GAS | 25 | CONTINUOUS | 0 | 0 | No | -- | -- | Annual Test. 35 PSI water and gas blew down to 25 PSI in thirty minutes. Water and gas observed throughout entire test, ~10 gals of water. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
| 404043476 | Form 17 | 11/27/2024 | 12/30/2024 | SHUT-IN | 28 | CONTINUOUS | LIQUID HYDROCARBON | 0 | CONTINUOUS | 690 | 690 | No | -- | -- | Remediation follow up test. 28 PSI blew down to 0 PSI within thirty minutes, continuous trickle of liquid hydrocarbons entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403703778 | Form 17 | 2/23/2024 | 2/29/2024 | PLUNGER LIFT | 26 | CONTINUOUS | WATER AND GAS | 26 | CONTINUOUS | 509 | 509 | No | -- | -- | Annual test. 26 PSI continuous water and gas flow maintained pressure for entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403299016 | Form 17 | 1/20/2023 | 1/23/2023 | PLUNGER LIFT | 30 | DOWN TO 0 | WATER AND GAS | 25 | CONTINUOUS | 313 | 315 | Yes | -- | -- | Annual Test. 30 PSI gas and water blew down to 25 PSI in 30 minutes. Constant stream of water for entire test, total 15 gallons. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 1/14/2022 | 2/21/2022 | | 28 | Down to Zero | -- | 0 | No Flow | 296 | 253 | No | No | No | |
| Click for Specifics | Full | 5/7/2021 | 12/21/2021 | | 26 | Water H2O | None | 20 | Water H2O | 436 | 380 | No | None | None | |
| Click for Specifics | Light | 11/1/2020 | 12/14/2020 | | 0 | | -- | 0 | | 480 | 480 | No | No | No | |
| Click for Specifics | Light | 6/11/2019 | 11/27/2019 | | 10 | | | 0 | No Flow | 591 | 591 | No | No | No | |
| 400399775 | Form 17 | 3/13/2013 | 4/4/2013 | PLUNGER LIFT | 43 | GAS | -- | <1 | GAS | 279 | 303 | No | -- | -- | Surface casing produced no fluid during the form 17 test. |