404083057 | Form 17 | 1/24/2025 | 2/5/2025 | SHUT-IN | 20 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 0 | 0 | No | -- | -- | Annual Test. 20 PSI gas and water blew down to 0 PSI within first minute of test, water continued to slowly drip throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
403684205 | Form 17 | 2/7/2024 | 2/12/2024 | SHUT-IN | 9 | CONTINUOUS | WATER AND GAS | 0 | DOWN TO 0 | 750 | 750 | No | -- | -- | Annual test. 9 PSI water and gas flow blew down to 0 PSI in 30 seconds, intermittent fluid started at 9 minute mark and lasted for remainder of the test, ~1/2 gallon total fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
403301006 | Form 17 | 1/11/2023 | 1/25/2023 | SHUT-IN | 11 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 680 | 680 | No | -- | -- | Annual Test. 11 PSI gas and water blew down to 0 PSI within first minute of test. 1 quart water at open then steady drip for remainder of test. PDC will continue to monitor monthly. |
403218552 | Form 17 | 11/2/2022 | 11/3/2022 | SHUT-IN | 2 | DOWN TO 0 | WATER AND GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Annual Test. 2 PSI water and gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
Click for Specifics | Full | 7/31/2021 | 11/1/2021 | | 20 | Down to Zero | -- | 0 | No Flow | 400 | 400 | No | None | None | |
Click for Specifics | Light | 9/20/2020 | 12/3/2020 | | 14 | | -- | 0 | No Flow | 375 | 375 | No | No | No | |
402294385 | Form 17 | 1/17/2020 | 1/24/2020 | FLOWING | 19 | DOWN TO 0 | -- | 0 | NO FLOW | 297 | 278 | No | -- | -- | Short surface casing. Annual. 19 psig initial surface casing pressure. Down to 0 psig within 5 minutes. No samples taken.
|
Click for Specifics | Full | 11/12/2019 | 12/24/2019 | | 18 | Down To Zero | -- | -- | | 348 | -- | No | No | No | Short surface casing. Below bradenhead threshold. No mitigation or Form 4 required. |