Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-17441WERNING
8-3
PDC ENERGY INC
69175
PR
3/1/2024
WATTENBERG
90750
EVANS/WELD  123
SENE 3 4N66W 6
332845
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404380337Form 179/17/202510/6/2025PLUNGER LIFT60SURGE WATER AND GAS11 SURGE 553553No----Remediation follow up test. 60 PSI gas and water, blew down to 11 PSI in thirty minutes, water and gas continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404225178Form 175/13/20256/2/2025PLUNGER LIFT79CONTINUOUS GAS1 WHISPER 488488No----Engineering Ad Hoc test. 79 PSI whisper water blew down to 1 PSI in thirty minutes. Whisper gas continued throughout entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
404159659Form 171/18/20254/9/2025PLUNGER LIFT46CONTINUOUS WATER AND GAS28 CONTINUOUS 500435No----Engineering Ad Hoc test. 46 PSI water and gas blew down to 28 PSI in thirty minutes. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
404008800Form 1711/21/202411/26/2024PLUNGER LIFT86CONTINUOUS WATER AND GAS0 WHISPER 595595No----Engineering Ad Hoc test. 86 PSI gas and water blew down to 0 PSI in thirty minutes, ~25 gal of water . PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403693151Form 172/16/20242/20/2024PLUNGER LIFT42CONTINUOUS WATER AND GAS42 CONTINUOUS 663663No----Annual test. 42 PSI continuous water, maintained pressure for 30 minutes. PDC will schedule a sampling event. PDC will monitor pressure and re-test according to bradenhead policy.
403298982Form 171/19/20231/23/2023PLUNGER LIFT38DOWN TO 0 WATER AND GAS10 CONTINUOUS 447447Yes----Annual Test. 38 PSI gas and water blew down to 10 PSI in 30 minutes. Constant stream of water for entire test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull10/24/202211/8/2022Plunger Lift36Down to Zero--0No Flow631632NoNoneNone 
Click for SpecificsFull7/23/202111/1/2021 35Continuous--0Continuous715715NoNoneNone 
Click for SpecificsLight10/2/202012/3/2020 44 --0No Flow515515NoNoNo 
Click for SpecificsLight6/13/201911/27/2019 0  0 655655NoNoNo