Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-103-10041WRD FEDERAL
19-21
KT RESOURCES LLC
10775
SI
3/1/2020
WHITE RIVER
92800
RIO BLANCO  103
SWNW 19 2N96W 6
336451
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1132 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403899828Form 178/21/20248/25/2024 0NO FLOW --0 NO FLOW 620620No---- 
403804969Form 175/23/20245/28/2024SHUT-IN0NO FLOW NONE0 NO FLOW 600600No---- 
403764005Form 174/22/20244/22/2024SHUT-IN0NO FLOW NONE0 NO FLOW 11951195No---- 
403696887Form 172/20/20242/23/2024SHUT-IN0NO FLOW NONE0 NO FLOW 580580No---- 
403442545Form 176/21/20236/22/2023SHUT-IN140DOWN TO 0 GAS0 NO FLOW 575575No---- 
403247661Form 1711/30/202212/2/2022SHUT-IN0NO FLOW NONE0 NO FLOW 580580No----This breadenhead test has indicated that there is no communication between the surface casing (8.625") and the 5.5" production casing. The lack of communication between casings and the fact that the production casing pressure did not change when the bradenhead was opened indicates that this well has pressure integrity in with the production casing. In my opinion this well protects the health, safety, welfare, the environment and wildlife resources in the environment. It is requested that this bradenhead test be accepted has an alternative MIT as it has shown wellbore integrity and KT Resources has been unable to contract a workover rig due to high demand of equipment in the current price environment. If approved this well will be turned onto production.
403220137Form 1710/16/202211/6/2022SHUT-IN4DOWN TO 0 --0 NO FLOW 570570No----This braden head test indicates that that there is no communication between the surface casing and production casing, therefore the wellbore has structural integrity and does not pose a threat to the environment.