| Click for Specifics | Light | 10/16/2025 | 11/5/2025 | | 9 | | -- | 0 | | 250 | 250 | No | No | No | |
| Click for Specifics | Light | 10/31/2024 | 11/4/2024 | | 2 | | -- | 0 | | 275 | 275 | No | No | No | |
| Click for Specifics | Light | 11/21/2023 | 12/11/2023 | Flowing | 0 | | -- | 0 | | 349 | 349 | No | No | No | |
| 403171194 | Form 17 | 9/15/2022 | 9/21/2022 | FLOWING | 0 | NO FLOW | NONE | 0 | NO FLOW | 303 | 303 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc# 402029267 |
| 402697023 | Form 17 | 5/13/2021 | 5/21/2021 | FLOWING | 48 | CONTINUOUS | GAS | 0 | NO FLOW | 239 | 253 | No | -- | -- | 48 psig initial surface casing pressure. No samples taken. |
| 402568790 | Form 17 | 12/30/2020 | 1/8/2021 | FLOWING | 73 | DOWN TO 0 | GAS | 0 | NO FLOW | 373 | 318 | Yes | Yes | No | 73 psig. initial surface casing pressure. Gas sample taken. |
| Click for Specifics | Light | 4/28/2020 | 5/18/2020 | | 14 | | -- | 0 | No Flow | 1106 | 1106 | No | No | No | Case 2 |
| 402038514 | Form 17 | 5/2/2019 | 5/10/2019 | FLOWING | 26 | DOWN TO 0 | -- | 0 | NO FLOW | 1621 | 1621 | No | -- | -- | P&A. 26 psig initial surface casing. Down to 0 psig within five minutes. No samples taken.
|
| 401289632 | Form 17 | 5/22/2017 | 5/23/2017 | SHUT-IN | 257 | CONTINUOUS | -- | 0 | NO FLOW | 327 | 328 | Yes | Yes | No | Blew down after two minutes. Samples taken from surface and production casing. |