404098675 | Form 17 | 2/4/2025 | 2/18/2025 | PLUNGER LIFT | 71 | CONTINUOUS | GAS | 1 | WHISPER | 508 | 507 | No | -- | -- | Engineering Ad Hoc test. 71 PSI gas blew down to 1 PSI in thirty minutes. Gas present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly. |
403911317 | Form 17 | 9/4/2024 | 9/5/2024 | | 51 | DOWN TO 0 | GAS | 0 | NO FLOW | 503 | 502 | No | -- | -- | Engineering Ad Hoc test. 51 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
Click for Specifics | Full | 4/15/2024 | 4/16/2024 | | 29 | Down to Zero | -- | 0 | Down to Zero | 693 | 700 | No | No | No | Annual Test. 29 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403687129 | Form 17 | 2/13/2024 | 2/14/2024 | SHUT-IN | 53 | CONTINUOUS | GAS | 0 | NO FLOW | 461 | 461 | No | -- | -- | Automation Alert follow-up test. 53 PSI gas blew down to whisper in 90 seconds, whisper lasted until 4 minute mark. No flow or pressure for the remainder of the test. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 4/14/2023 | 4/24/2023 | | 40 | Down to Zero | -- | 0 | Down to Zero | 682 | 681 | No | None | None | Annual Test. 40 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
Click for Specifics | Full | 10/11/2022 | 11/8/2022 | Shut-In | 35 | Down to Zero | -- | 0 | Down to Zero | 396 | 396 | No | None | None | |
402839859 | Form 17 | 9/30/2021 | 10/13/2021 | FLOWING | 46 | DOWN TO 0 | GAS | 0 | NO FLOW | 1042 | 1049 | No | -- | -- | Retest after blowdown period and build up since 9/16/2021. Gas for 13 seconds at open then dead for remainder of test. |
402656478 | Form 17 | 4/6/2021 | 4/13/2021 | FLOWING | 71 | CONTINUOUS | GAS | 0 | NO FLOW | 970 | 972 | Yes | Yes | No | Test per NTO. Gas at open. Sampled then gas slowing to dead at 7 minute mark. Dead for remainder of test. |
402523095 | Form 17 | 10/28/2020 | 10/30/2020 | FLOWING | 10 | GAS | -- | 0 | NO FLOW | 1042 | 1041 | No | -- | -- | 6 month retest. Gas for 20 seconds at open then dead. |
402388328 | Form 17 | 5/1/2020 | 5/4/2020 | FLOWING | 6 | GAS | -- | 0 | NO FLOW | 29 | 29 | No | -- | -- | Test after displacment and 40 day build up. Gas for 13 seconds then dead. |
402248355 | Form 17 | 11/21/2019 | 11/25/2019 | FLOWING | 594 | CONTINUOUS | -- | 0 | CONTINUOUS | 1522 | 1522 | No | -- | -- | Test per NTO. Blew down through 2" line to frac tank. Continuous gas through test till 28 min mark. Then blew to a whisper. 0 psi and whisper on shut. |
402084385 | Form 17 | 6/14/2019 | 6/21/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 1594 | 1595 | No | -- | -- | Test after DOFP. Bradenhead dead. Well was turned back on at the 20 minute mark. |
401967698 | Form 17 | 3/7/2019 | 3/11/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. |