Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10094B-Farm LD
18-392HC
PDC ENERGY INC
69175
PR
12/1/2022
WATTENBERG
90750
ADAMS  001
NENW 7 1S67W 6
452914
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1756 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403753588Form 174/12/20244/15/2024PLUNGER LIFT63DOWN TO 0 WATER AND LIQUID HYDROCARBON0 CONTINUOUS 375388No----Annual test. 63 PSI fluid flow blew down to 0 PSI within first minute of test. Fluid trickled for entire test, ~1 quart fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403416016Form 175/29/20235/30/2023PLUNGER LIFT6CONTINUOUS GAS0 NO FLOW 406414No----Abatement system follow up test. 6 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403191738Form 1710/6/202210/10/2022PLUNGER LIFT64DOWN TO 0 GAS0 NO FLOW 419413No----Automation Alert test. 64 PSI gas flow blew down to 0 PSI in five minutes with no flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403094933Form 176/29/20227/1/2022PLUNGER LIFT69DOWN TO 0 GAS0 NO FLOW 457455No----Test after pressure discovery. Gaseous on open for 5 seconds. Unable to collect sample due to lack of volume. No flow for remainder of test.
402858635Form 1710/22/202111/1/2021FLOWING46DOWN TO 0 GAS0 NO FLOW 513516No----Retest after displacement and build up since 9/4/2021. Gas for 15 seconds at open then dead for remainder of test.
402809856Form 179/4/20219/14/2021FLOWING68DOWN TO 0 GAS0 NO FLOW 525540No----Retest. Gas for 30 seconds at open then dead for remainder of test.
402299911Form 171/21/20201/30/2020FLOWING117MUD --0 MUD 11681168No----Test after 5 week blowdown and 1 week build up. blew down to trickle in 5 seconds. Made ~ 1 gallon total. No phase change from 2019 NTO test and sampling. no sample taken.
402137722Form 178/5/20198/8/2019FLOWING110MUD --0 MUD 21312131Yes--YesTest after DOFP. 500 ml sample taken. BH PSI after sample 10 PSI. Blew down to trickle in 10 seconds. Made 1 gallon total.
401989359Form 173/26/20193/29/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac. Slight vacuum on open.