Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10091B-Farm LD
18-037HC
PDC ENERGY INC
69175
PR
12/1/2022
WATTENBERG
90750
ADAMS  001
NENW 7 1S67W 6
452914
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1721 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403756558Form 174/12/20244/16/2024PLUNGER LIFT24DOWN TO 0 WATER AND GAS0 CONTINUOUS 395401No----Annual test. 24 PSI water and gas flow blew down to 0 PSI in 1 minute. No flow or pressure until 12 minute mark when water started to trickle and lasted for the remainder of the test, ~1 quart total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403418270Form 175/29/20235/31/2023PLUNGER LIFT32CONTINUOUS WATER AND GAS0 DOWN TO 0 596596No----Annual Test. 32 PSI blew down to 0 PSI within first five minutes of test. On and off water was observed at 7 minute mark and lasted for the remainder of test. No pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403216135Form 1710/20/202211/2/2022PLUNGER LIFT40DOWN TO 0 WATER AND GAS0 CONTINUOUS 667665Yes----Annual Test. 40 PSI water and gas flow blew down to 0 PSI within first minute of test. Water continued for entire test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402846389Form 1710/18/202110/19/2021PLUNGER LIFT27DOWN TO 0 WATER H200 NO FLOW 970969No----Re-test, water on open. Produced ~ 1/2 quart and died. No flow for remainder of test. Not enough volume to collect sample.
402548452Form 1711/30/202012/7/2020FLOWING14WHISPER GAS0 CONTINUOUS 974973No----Test per NTO. Whisper for 2 seconds. Drips of water started at 12 minutes for remainder of test. Did not make enough to sample.
402137770Form 178/5/20198/8/2019SHUT-IN0NO FLOW --0 NO FLOW 15291528No----Test Per NTO. BH dead.
401628858Form 175/1/20185/3/2018FLOWING177WHISPER --0 NO FLOW 24542451YesYes--Test taken within 30 days of DOFP. Blew down to Whisper in less than 10 seconds.
401551367Form 172/24/20182/28/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----