Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10069Prairie LE
17-013HN
PDC ENERGY INC
69175
PR
9/4/2021
WATTENBERG
90750
BRIGHTON/ADAMS  001
SESW 20 1S66W 6
450942
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2029 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/13/202511/17/2025 7Down to Zero--0No Flow420422NoNoNo Annual Test.  7 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/15/20244/30/2024 0Down to Zero--0Down to Zero532530NoNoNo 
Click for SpecificsFull8/1/20238/14/2023Shut In17Down to Zero--0Down to Zero432432NoNoNoAnnual Test. 17 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/10/202211/8/2022Gas Lift5Down to Zero--0Down to Zero528528NoNoneNone 
402835666Form 1710/7/202110/8/2021FLOWING2WHISPER GAS0 NO FLOW 11951195No----Test after DOFP. Whisper on open for 2 seconds and died. No flow for remainder of test.
402726066Form 176/21/20216/22/2021SHUT-IN--NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 15 seconds.