Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-09966Seltzer LD
21-032HNX
PDC ENERGY INC
69175
PR
4/1/2022
WATTENBERG
90750
ADAMS  001
NWNE 4 1S67W 6
320515
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1744 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403969581Form 1710/22/202410/24/2024PLUNGER LIFT10DOWN TO 0 GAS0 NO FLOW 328329No----Remediation follow up test. 10 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull12/8/202312/11/2023Flowing13Down to Zero--0No Flow413412NoNoNoAnnual Test. 13 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403282909Form 171/6/20231/9/2023PLUNGER LIFT104DOWN TO 0 MUD0 CONTINUOUS 535531Yes----Automation Alert follow-up. 104 PSI blew down to 0 PSI within 5 minutes. Mud on open, collected 40mL bradenhead and production sample. Produced ~ 1/2 cup of mud and died to trickle/drip. Trickle/drip for duration of test and produced ~1qt total. Displaced after test and collected 1000mL water sample from displacement/fluid pull returns.
Click for SpecificsFull11/28/202211/29/2022 26Down to Zero--0No Flow524522NoNoneNone 
402811997Form 179/9/20219/15/2021PLUNGER LIFT47DOWN TO 0 GAS0 NO FLOW 698698No----Test after displacement and 56 day build up. Gas on open for 5 seconds and died. No flow for the remainder of test.
402678535Form 174/24/20215/3/2021FLOWING61CONTINUOUS MUD0 CONTINUOUS 791790YesNoYesTest per NTO. Non aqeuous liquid at open. Continuous for entire test.
402523014Form 1710/22/202010/30/2020FLOWING29GAS --0 NO FLOW 918916No----6 month retest. Gas for 2 seconds at open then dead.
402388297Form 174/22/20205/4/2020FLOWING5GAS --0 NO FLOW 11521157No----Test after displacment and 29 day build up. Gas for 10 seconds then dead.
402306726Form 171/29/20202/7/2020FLOWING86MUD --0 MUD 13261325Yes--YesTest after 5 week blowdown and 13 day buildup. Mud trickle at open made ~ 1 quart total. 40mL non-aqueous BH sample collected and 40mL production oil sample taken.
401966002Form 173/7/20193/8/2019FLOWING167NO FLOW --0 WATER H20 23632361No----Test after DOFP. Bradenhead bled down thru 1/4" needle valve in less than 1 second. After 10 minute interval a water drip began and was intermittent throughout the remainder of the test. Not enough water was produced to collect an adequate water sample.
401877002Form 1712/14/201812/17/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac