Surface Casing Depth: 1774 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404204161Form 174/30/20255/14/2025GAS LIFT35CONTINUOUS WATER AND GAS1 WHISPER 826826No----Annual Test. 35 PSI continuous water and gas blew down to 1 PSI within thirty minutes of test. Whisper water observed for entire test, ~1 gal of fluid collected. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull11/6/202411/12/2024 2Whisper (very low flow)--0Down to Zero00NoNoNoAnnual Test.  2 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403851907Form 177/3/20247/11/2024 0NO FLOW NONE0 NO FLOW 567566No----Remediation follow up test. 0 PSI, no pressure or flow observed. PDC will monitor pressure and re-test according to bradenhead policy.
403631707Form 1712/20/202312/20/2023SHUT-IN51DOWN TO 0 GAS0 NO FLOW 588588No----High Pressure Verification follow up test. 51 PSI gas flow blew down to 0 PSI in 3 seconds. No flow or pressure for remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
403298138Form 171/19/20231/23/2023PLUNGER LIFT76DOWN TO 0 WATER AND GAS0 CONTINUOUS 449450Yes----Automation Alert follow-up test. 76 PSI gas flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. 1 cup of water on open then steady trickle for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull10/20/202211/8/2022Plunger Lift0Down to Zero--0Down to Zero409410NoNoneNone 
402846406Form 1710/18/202110/19/2021PLUNGER LIFT11DOWN TO 0 GAS0 NO FLOW 454458No----Re-test after displacement and 44 day build up. Gas on open for 15 seconds and died. No flow for remainder of test.
402703910Form 175/19/20215/28/2021FLOWING50DOWN TO 0 GAS0 NO FLOW 578579YesYesNoTest per NTO. Gas at open. Gas sampled then reopened full. Gas for 10 seconds then dead for remainder of test.
402556721Form 1712/7/202012/17/2020PLUNGER LIFT--NO FLOW NONE0 NO FLOW 786791No----Test after cat heater was removed and fluid pull was performed on 10/27/2020. Test after ~40 day buildup.
402520995Form 1710/27/202010/28/2020FLOWING97WATER H20 --0 WATER H20 814813Yes--YesTest after cat heater mitigation. BH cut to water and cat heater mitigation will no longer be a viable option for mitigation. Water on open, and intermittent trickle for duration of test. 1000 mL sample collected. Made ~ 2 gallons of water total.
402260883Form 1712/9/201912/11/2019FLOWING910CONTINUOUS --0 CONTINUOUS 24782478No----Test after DOFP. BH and Prod gas sample taken. Attempted to blow down thru 1/4" NV. BH PSI was 20 PSI after 15 minutes. Slightly above whisper at the end of test. ISIP 0 PSI.
402182393Form 179/14/20199/19/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac.