View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404210753Form 175/5/20255/20/2025GAS LIFT108CONTINUOUS WATER AND GAS1 WHISPER 508505No----Engineering Ad Hoc test. 108 PSI water and gas blew down to 1 PSI in thirty minutes. Whisper water observed for entire test, ~3 gal. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403846211Form 176/28/20247/5/2024 70CONTINUOUS WATER AND GAS70 CONTINUOUS 628628No----Annual Test. 70 PSI water and gas, never blew down. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403618539Form 1712/6/202312/7/2023FLOWING54CONTINUOUS WATER AND LIQUID HYDROCARBON0 DOWN TO 0 761760No----Abatement system follow up test. 54 PSI fluid flow blew down to 0 PSI within first minute of test. Intermittent fluid for entire test, ~1.5 gallons total. PDC will monitor pressure and re-test according to bradenhead policy. Abatement shut for only 2 days instead of 7.
403444760Form 176/22/20236/26/2023FLOWING95CONTINUOUS MUD AND GAS0 CONTINUOUS 852852Yes----Automation Alert follow-up test. 95 PSI gas and muddy fluid on open, fluid trickled for entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403150726Form 178/29/20228/30/2022FLOWING116DOWN TO 0 GAS0 NO FLOW 13701370Yes----Engineering Ad Hoc test, 116 PSI gas flow blew down to 0 PSI in five minutes with no flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403074796Form 176/1/20226/10/2022FLOWING155CONTINUOUS GAS0 NO FLOW 17011701YesYes--Test after pressure discovery. Gaseous on open, collected BH and Prod gas samples. Gas for 2 minutes and died, no flow for remainder of test.
402833342Form 1710/5/202110/6/2021FLOWING32DOWN TO 0 MUD0 NO FLOW 29502950Yes--YesTest after DOFP. Mud on open, collected BH and production sample. Surged for 15 minutes and died. No flow for remainder of test.
402697897Form 175/12/20215/22/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 1 minute and 6 seconds.