Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#280887 Information View DocsDoc View GISGIS
Sample Site ID280887
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSW 3 2N65W
Elevation4850Lat/Long40.161879/-104.657145
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-23320Well Name:CANNON 13-3
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSW  3  2N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   560165     Sample Date:  07/20/2017     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  ISOTECH

Sample Results for Sample # 560165    ISOTECH ID: 622901
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1295BTU
SOPBUTANE2.09MOL %0.0001
SOPC6+ (hexanes +)0.0823MOL %0.0001
SOPCARBON DIOXIDE2.32MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.45
SOPDELTA 13C C2-32.25
SOPDELTA 13C C3-28.58
SOPDELTA 13C iC4-31.06
SOPDelta 13C iC5-27.92
SOPDELTA 13C nC4-27.61
SOPDelta 13C nC5-26.83
SOPDELTA D C1-246.7
SOPETHANE14.79MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0066MOL %0.005
SOPHYDROGEN0.157MOL %0.01
SOPISOBUTANE0.891MOL %0.0001
SOPISOPENTANE0.433MOL %0.0001
SOPMETHANE72.06MOL %0.0002
SOPNITROGEN (N2)0.3MOL %0.01
SOPOXYGEN (O2)0.014MOL %0.01
SOPPENTANE0.422MOL %0.0001
SOPPROPANE6.43MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.773RATIO_AIR

 Sample ID:   560167     Sample Date:  07/20/2017     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 560167    ISOTECH ID: 622902
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0145MOL %0.005
SOPBRITISH THERMAL UNITS1266BTU
SOPBUTANE1.58MOL %0.0001
SOPC6+ (hexanes +)0.962MOL %0.0001
SOPCARBON DIOXIDE0.006MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.68
SOPDELTA 13C C2-31.89
SOPDELTA 13C C3-28.98
SOPDELTA 13C iC4-31.34
SOPDelta 13C iC5-28.37
SOPDELTA 13C nC4-28.04
SOPDelta 13C nC5-27.4
SOPDELTA D C1-243.4
SOPETHANE10.57MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0307MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANE0.739MOL %0.0001
SOPISOPENTANE0.428MOL %0.0001
SOPMETHANE78.47MOL %0.0002
SOPNITROGEN (N2)1.66MOL %0.01
SOPOXYGEN (O2)0.22MOL %0.01
SOPPENTANE0.471MOL %0.0001
SOPPROPANE4.85MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.735RATIO_AIR

 Sample ID:   560285     Sample Date:  07/20/2017     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 560285    Weatherford Laboratories  ID: 6126640914
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane1797ppm
G02G1,1-dimethylcyclopentane1431ppm
G02G1,2,3-trimethylcyclopentane1129ppm
G02G1,2,4-trimethylcyclopentane1463ppm
G02G2,2,3-trimethylbutane96ppm
G02G2,2-DIMETHYLBUTANE117ppm
G02G2,2-dimethylpentane488ppm
G02G2,3-DIMETHYLBUTANE702ppm
G02G2,3-dimethylpentane270ppm
G02G2,3-dimethylpentane1772ppm
G02G2,4-dimethylpentane1106ppm
G02G2-METHYLPENTANE5249ppm
G02G3-ethylpentane442ppm
G02G3-methylhexane7475ppm
G02G3-methylhexane7480ppm
G02G3-METHYLPENTANE3484ppm
G02GBENZENE1724ppm
G02GBUTANE1417ppm
G02Gcis-1,3-dimethylcyclopentane1951ppm
G02GCYCLOHEXANE7302ppm
G02GCYCLOPENTANE548ppm
G02GDecane18075ppm
G02GETHYLBENZENE2027ppm
G02Gethylcyclopentane805ppm
G02GHEPTANES, MIXED ISOMERS22031ppm
G02GHEXANES12934ppm
G02Ghighly branched C25 isoprenoid308ppm
G02GISOBUTANE321ppm
G02GISOPENTANE2533ppm
G02Gisoprenoid C103626ppm
G02Gisoprenoid C113203ppm
G02Gisoprenoid C133307ppm
G02Gisoprenoid C142467ppm
G02Gisoprenoid C152952ppm
G02Gisoprenoid C163978ppm
G02Gisoprenoid C183319ppm
G02Gisoprenoid C92222ppm
G02Gm-XYLENE16673ppm
G02GMETHYL CYCLOHEXANE24837ppm
G02GMETHYLCYCLOPENTANE5480ppm
G02Gn-C1116884ppm
G02Gn-C1214170ppm
G02Gn-C1313127ppm
G02Gn-C1411666ppm
G02Gn-C1510662ppm
G02Gn-C168972ppm
G02Gn-C178023ppm
G02Gn-C186658ppm
G02Gn-C195879ppm
G02Gn-C205350ppm
G02Gn-C214490ppm
G02Gn-C224044ppm
G02Gn-C233518ppm
G02Gn-C243076ppm
G02Gn-C252610ppm
G02Gn-C262252ppm
G02Gn-C271749ppm
G02Gn-C281454ppm
G02Gn-C291312ppm
G02Gn-C301032ppm
G02Gn-C31849ppm
G02Gn-c32650ppm
G02Gn-C33605ppm
G02Gn-C34509ppm
G02Gn-C35432ppm
G02Gn-C36326ppm
G02Gn-C37316ppm
G02Gn-C38236ppm
G02Gn-C39217ppm
G02Gn-C40173ppm
G02Gn-C41105ppm
G02Gn-octane24672ppm
G02GNormal Alkane C920715ppm
G02Go-XYLENE5939ppm
G02Gp-XYLENE5600ppm
G02GPENTANE4665ppm
G02GPHENANTHRENE232ppm
G02Gphytane2014ppm
G02Gpristane3730ppm
G02GPropyl-benzene1600ppm
G02GTOLUENE15686ppm
G02Gtrans-1,2-dimethylcyclopentane2864ppm
G02Gtrans-1,3-dimethylcyclopentane1848ppm