Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#280708 Information View DocsDoc View GISGIS
Sample Site ID280708
FacilityTypeOGProj Number1931
CountyWELD - 123LocationNENW 30 2N68W
ElevationLat/Long40.114844/-105.049142
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-23298Well Name:BALLANTINE 3-30
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NENW  30 2N  68W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   459781     Sample Date:  10/31/2006     Matrix:  GAS     Collection Point:       Type:  PRDG     Lab:  Isotech Laboratories

Sample Results for Sample # 459781    Isotech Laboratories ID: 106031
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
UnSpecARGONNDMOL %U
UnSpecBUTANE1.12MOL %
UnSpecCARBON DIOXIDE1.65MOL %
UnSpecDELTA 13C C1-47.42per mil VPDB
UnSpecDELTA 13C C2-32.23per mil VPDB
UnSpecDELTA 13C C3-28.68per mil VPDB
UnSpecDELTA 13C CO22.79per mil VPDB
UnSpecDELTA D C1-232.3per mil VSMOW
UnSpecETHANE14.07MOL %
UnSpecHelium0.0063Mol %
UnSpecHEXANES0.0917Mol %
UnSpecHYDROGEN0.002MOL %
UnSpecISOBUTANE0.572MOL %
UnSpecISOPENTANE0.192MOL %
UnSpecMETHANE76.7MOL %
UnSpecNITROGEN (N2)0.31MOL %
UnSpecOXYGEN (O2)NDMOL %U
UnSpecPENTANE0.165MOL %
UnSpecPROPANE5.12MOL %

 Sample ID:   612585     Sample Date:  10/21/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 612585    ISOTECH ID: 738887
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.584MOL %0.005
SOPBRITISH THERMAL UNITS382BTU
SOPBUTANE0.398MOL %0.0001
SOPC6+ (hexanes +)0.0417MOL %0.0001
SOPCARBON DIOXIDE0.11MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-56.37
SOPDELTA 13C C2-33.18
SOPDELTA 13C C3-29.37
SOPDELTA 13C iC4-31.49
SOPDelta 13C iC5-27.53
SOPDELTA 13C nC4-28.07
SOPDELTA D C1-272.1
SOPETHANE0.756MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0394MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.179MOL %0.0001
SOPISOPENTANE0.0988MOL %0.0001
SOPMETHANE31.25MOL %0.0002
SOPNITROGEN (N2)52.48MOL %0.01
SOPOXYGEN (O2)13.04MOL %0.01
SOPPENTANE0.0986MOL %0.0001
SOPPROPANE0.921MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.874RATIO_AIR

 Sample ID:   612586     Sample Date:  10/21/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 612586    ISOTECH ID: 738886
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0113MOL %0.005
SOPBRITISH THERMAL UNITS1243BTU
SOPBUTANE1.63MOL %0.0001
SOPC6+ (hexanes +)0.142MOL %0.0001
SOPCARBON DIOXIDE1.57MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.83
SOPDELTA 13C C2-32.49
SOPDELTA 13C C3-28.97
SOPDELTA 13C CO21.18
SOPDELTA 13C iC4-31.43
SOPDelta 13C iC5-28.24
SOPDELTA 13C nC4-27.77
SOPDelta 13C nC5-27.36
SOPDELTA D C1-243.6
SOPETHANE12.17MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0099MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.724MOL %0.0001
SOPISOPENTANE0.338MOL %0.0001
SOPMETHANE76.02MOL %0.0002
SOPNITROGEN (N2)1.18MOL %0.01
SOPOXYGEN (O2)0.22MOL %0.01
SOPPENTANE0.34MOL %0.0001
SOPPROPANE5.64MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.74RATIO_AIR

 Sample ID:   612583     Sample Date:  10/21/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 612583    Accutest ID: DA21321-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON1.33mg/L0.05
E200.7CALCIUM10mg/L0.4
E200.7IRON0.0336mg/L0.01
E200.7MAGNESIUM2.36mg/L0.2
E200.7MANGANESE0.0586mg/L0.005
E200.7POTASSIUM6.48mg/L1
E200.7SODIUM1370mg/L8
E200.7STRONTIUM0.959mg/L0.005
E200.8BARIUM0.493mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE17.3mg/L0.5
E300.0CHLORIDE1800mg/L50
E300.0FLUORIDENDmg/L1U
E300.0NITRATENDmg/L0.1U
E300.0Nitrite as NO2NDmg/L0.04U
E300.0SULFATENDmg/L5U
FIELDpH, FIELD9.8SU
FIELDSPECIFIC CONDUCTIVITY, FIELD6130UMHOS/CM0.5
FIELDTEMPERATURE, FIELD12.9degrees C
SM1030CATION - ANION BALANCE2.6%
SM2320BBICARBONATE ALKALINITY as CACO398.6mg/L5
SM2320BCARBONATE ALKALINITY AS CACO392.6mg/L5
SM2320BTOTAL ALKALINITY AS CACO3191mg/L5
SW8015TEPH DIESEL RANGE ORGANICS3.75mg/L2
SW8015TVPH - Gasoline Range Organics0.45mg/L0.05
SW8260BENZENE50.1ug/L1
SW8260ETHYLBENZENE12.3ug/L1
SW8260M-+P-XYLENE36.6ug/L1
SW8260o-XYLENE6ug/L1
SW8260TOLUENE12.1ug/L1
SW8260TOTAL XYLENES42.6ug/L1

 Sample ID:   612584     Sample Date:  10/21/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 612584    Accutest ID: DA21322-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   629557     Sample Date:  08/11/2021     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 629557    ISOTECH ID: 801524
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.886MOL %0.005
SOPBRITISH THERMAL UNITS111BTU
SOPBUTANE0.526MOL %0.0001
SOPC6+ (hexanes +)0.153MOL %0.0001
SOPCARBON DIOXIDE0.11MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-54.52
SOPDELTA 13C C2-33.06
SOPDELTA 13C C3-29.75
SOPDELTA 13C CO2-8.6
SOPDELTA 13C iC4-32.3
SOPDelta 13C iC5-28.6
SOPDELTA 13C nC4-28.2
SOPDelta 13C nC5-27.5
SOPDELTA D C1-254.8
SOPETHANE0.315MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0067MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.163MOL %0.0001
SOPISOPENTANE0.229MOL %0.0001
SOPMETHANE4.24MOL %0.0002
SOPNITROGEN (N2)72.72MOL %0.01
SOPOXYGEN (O2)19.88MOL %0.01
SOPPENTANE0.256MOL %0.0001
SOPPROPANE0.52MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY1.002RATIO_AIR

 Sample ID:   629558     Sample Date:  08/11/2021     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 629558    ISOTECH ID: 801523
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1287BTU
SOPBUTANE1.74MOL %0.0001
SOPC6+ (hexanes +)0.837MOL %0.0001
SOPCARBON DIOXIDE1.32MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.2
SOPDELTA 13C C2-32.64
SOPDELTA 13C C3-29.01
SOPDELTA 13C CO22.37
SOPDELTA 13C iC4-31.6
SOPDelta 13C iC5-28.56
SOPDELTA 13C nC4-28.02
SOPDelta 13C nC5-27.71
SOPDELTA D C1-240.6
SOPETHANE11.95MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0156MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.702MOL %0.0001
SOPISOPENTANE0.539MOL %0.0001
SOPMETHANE76.87MOL %0.0002
SOPNITROGEN (N2)0.42MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.633MOL %0.0001
SOPPROPANE4.97MOL %0.0001
SOPPROPENE0.0002MOL %0.0001
SOPSPECIFIC GRAVITY0.753RATIO_AIR

 Sample ID:   629555     Sample Date:  08/11/2021     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 629555    Accutest ID: DA36694-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8BARIUM0.479mg/L0.002
E200.8BORON1.23mg/L0.04
E200.8CALCIUM8.77mg/L0.4
E200.8IRON1.46mg/L0.02
E200.8MAGNESIUM2.24mg/L0.1
E200.8MANGANESE0.0659mg/L0.001
E200.8POTASSIUM4.7mg/L0.2
E200.8SELENIUMNDmg/L0.0004U
E200.8SODIUM1350mg/L50
E200.8STRONTIUM0.97mg/L0.4
E300.0BROMIDE17.4mg/L0.5
E300.0CHLORIDE1890mg/L50
E300.0FLUORIDENDmg/L1U
E300.0NITRATENDmg/L0.1U
E300.0NITRITENDmg/L0.4U
E300.0SULFATENDmg/L5U
FIELDpH, FIELD9.5SU
FIELDSPECIFIC CONDUCTIVITY, FIELD6790UMHOS/CM0.5
FIELDTEMPERATURE, FIELD27.9degrees C
SM1030CATION - ANION BALANCE1.9%
SM2320BBICARBONATE ALKALINITY as CACO3113mg/L5
SM2320BCARBONATE ALKALINITY AS CACO342mg/L5
SM2320BTOTAL ALKALINITY AS CACO3183mg/L5
SW8015TEPH DIESEL RANGE ORGANICS13.4mg/L0.4
SW8015TVPH - Gasoline Range Organics0.446mg/L0.05
SW8260BENZENE53.1ug/L1
SW8260ETHYLBENZENE11.3ug/L1
SW8260M-+P-XYLENE33.1ug/L1
SW8260o-XYLENE5.5ug/L1
SW8260TOLUENE17.7ug/L1
SW8260TOTAL XYLENES38.6ug/L1

 Sample ID:   629556     Sample Date:  08/11/2021     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 629556    Accutest ID: DA36693-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U