Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#250389 Information View DocsDoc View GISGIS
Sample Site ID250389
FacilityTypeOGProj Number
CountyWELD - 123LocationNESE 2 3N67W
Elevation4762Lat/Long40.25269/-104.85171
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-18192Well Name:HSR-HUFFMAN 9-2A
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NESE  2  3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   601335     Sample Date:  05/25/2018     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 601335    ISOTECH ID: 665682
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.62mg/L0.01
SOPETHANE0.22mg/L0.0002
SOPMETHANE22mg/L0.0002
SOPNITROGEN (N2)28mg/L0.02
SOPPROPANE0.28mg/L0.0003

 Sample ID:   601336     Sample Date:  05/25/2018     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 601336    ISOTECH ID: 665682
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.582MOL %0.005
SOPBRITISH THERMAL UNITS548BTU
SOPBUTANE0.186MOL %0.0001
SOPC6+ (hexanes +)0.0158MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDE0.077MOL %0.01
SOPDELTA 13C C1-70.46
SOPDELTA 13C C2-33.3
SOPDELTA 13C C3-27.9
SOPDELTA D C1-296.7
SOPETHANE0.253MOL %0.0001
SOPETHENE0.0028MOL %0.0001
SOPHELIUM DILUTION FACTOR0.59NA
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANE0.0843MOL %0.0001
SOPISOPENTANE0.0593MOL %0.0001
SOPMETHANE51.74MOL %0.0002
SOPNITROGEN (N2)42.19MOL %0.01
SOPOXYGEN (O2)4.54MOL %0.01
SOPPENTANE0.03MOL %0.0001
SOPPROPANE0.235MOL %0.0001
SOPPROPENE0.0008MOL %0.0001
SOPSPECIFIC GRAVITY0.768RATIO_AIR

 Sample ID:   601337     Sample Date:  05/25/2018     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 601337    Accutest ID: DA5681-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.349mg/L0.05
E200.7CALCIUM6.16mg/L0.4
E200.7IRON0.41mg/L0.01
E200.7MAGNESIUMNDmg/L0.2U
E200.7MANGANESE0.0079mg/L0.005
E200.7POTASSIUM5.21mg/L1
E200.7SODIUM435mg/L4
E200.7STRONTIUM0.114mg/L0.005
E200.8BARIUM0.914mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE3.4mg/L1.3
E300.0CHLORIDE430mg/L13
E300.0FLUORIDE3.6mg/L2.5
E300.0NITRATE0.79mg/L0.25
E300.0NITRATE/NITRITE AS N0.79mg/L0.35
E300.0Nitrite as NO2NDmg/L0.1U
E300.0SULFATE1.8mg/L1
FIELDpH, FIELD9.9SU
FIELDSPECIFIC CONDUCTIVITY, FIELD2120UMHOS/CM0.5
FIELDTEMPERATURE, FIELD18.2degrees C
SM1030CATION - ANION BALANCE0.69%
SM2320BBICARBONATE ALKALINITY as CACO3163mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3211mg/L5
SM2320BTOTAL ALKALINITY AS CACO3374mg/L5
SM2510BSPECIFIC CONDUCTIVITY2000UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS1130mg/L10
SM4500-H+ BpH, FIELD10SU
SW8015TVPH - Gasoline Range Organics1.13mg/L0.05
SW8260BENZENE30.1ug/L1
SW8260ETHYLBENZENE12.6ug/L1
SW8260M-+P-XYLENE154ug/L1
SW8260o-XYLENE48.2ug/L1
SW8260TOLUENE165ug/L1
SW8260TOTAL XYLENES202ug/L1

 Sample ID:   601338     Sample Date:  05/25/2018     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 601338    Accutest ID: DA5682-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U