Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#242931 Information View DocsDoc View GISGIS
Sample Site ID242931
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSE 11 3N67W
Elevation4744Lat/Long40.23597/-104.85497
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-10722Well Name:FORT ST VRAIN 14
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSE  11 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   620094     Sample Date:  10/06/2020     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 620094    ISOTECH ID: 773109
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0933MOL %0.005
SOPBRITISH THERMAL UNITS1065BTU
SOPBUTANE1.13MOL %0.0001
SOPC6+ (hexanes +)0.24MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-58.3
SOPDELTA 13C C2-31.6
SOPDELTA 13C C3-27.8
SOPDELTA 13C iC4-30.7
SOPDelta 13C iC5-28.1
SOPDELTA 13C nC4-27.3
SOPDelta 13C nC5-26.7
SOPDELTA D C1-255
SOPETHANE5.75MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.18MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.843MOL %0.0001
SOPISOPENTANE0.282MOL %0.0001
SOPMETHANE74.99MOL %0.0002
SOPNITROGEN (N2)12MOL %0.01
SOPOXYGEN (O2)0.12MOL %0.01
SOPPENTANE0.238MOL %0.0001
SOPPROPANE4.13MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.717RATIO_AIR

 Sample ID:   620095     Sample Date:  10/06/2020     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 620095    ISOTECH ID: 773108
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.743MOL %0.005
SOPBRITISH THERMAL UNITS287BTU
SOPBUTANE0.464MOL %0.0001
SOPC6+ (hexanes +)0.0463MOL %0.0001
SOPCARBON DIOXIDE0.078MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.1
SOPDELTA 13C C2-31.8
SOPDELTA 13C C3-28.3
SOPDELTA 13C CO2-12.5
SOPDELTA 13C iC4-31.3
SOPDelta 13C iC5-28.4
SOPDELTA 13C nC4-27.3
SOPDelta 13C nC5-27
SOPDELTA D C1-234
SOPETHANE3.46MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.687MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.227MOL %0.0001
SOPISOPENTANE0.104MOL %0.0001
SOPMETHANE15.2MOL %0.0002
SOPNITROGEN (N2)61MOL %0.01
SOPOXYGEN (O2)16.42MOL %0.01
SOPPENTANE0.0809MOL %0.0001
SOPPROPANE1.49MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.946RATIO_AIR

 Sample ID:   620109     Sample Date:  10/06/2020     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 620109    Accutest ID: DA29530-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   620093     Sample Date:  10/06/2020     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 620093    Accutest ID: DA29520-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.96mg/L0.05
E200.7CALCIUM3.74mg/L0.4
E200.7IRON0.0584mg/L0.01
E200.7MAGNESIUM0.203mg/L0.2
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUM1.84mg/L1
E200.7SODIUM383mg/L0.4
E200.7STRONTIUM0.184mg/L0.005
E200.8BARIUM0.0598mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE4.7mg/L0.1
E300.0CHLORIDE567mg/L25
E300.0FLUORIDE3.7mg/L0.2
E300.0NITRATENDmg/L0.02U
E300.0Nitrite as NO2NDmg/L0.2U
E300.0SULFATENDmg/L1U
FIELDpH, FIELD9.8SU
FIELDSPECIFIC CONDUCTIVITY, FIELD2910UMHOS/CM0.5
FIELDTEMPERATURE, FIELD14.1degrees C
RSK175ETHANE1.98mg/L0.08
RSK175METHANE7.44mg/L0.04
RSK175PROPANE0.847mg/L0.0022
SM1030CATION - ANION BALANCE2.9%
SM2320BBICARBONATE ALKALINITY as CACO312.5mg/L5
SM2320BCARBONATE ALKALINITY AS CACO370mg/L5
SM2320BTOTAL ALKALINITY AS CACO382.5mg/L5
SM2510BSPECIFIC CONDUCTIVITY1190UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS1030mg/L10
SM4500-H+ BpH, FIELD9.99SU
SW8015TEPH DIESEL RANGE ORGANICS2.24mg/L0.19
SW8015TVPH - Gasoline Range Organics2.37mg/L0.25
SW8260BENZENE122ug/L10
SW8260ETHYLBENZENE35.2ug/L10
SW8260M-+P-XYLENE285ug/L10
SW8260o-XYLENE110ug/L10
SW8260TOLUENE486ug/L10
SW8260TOTAL XYLENES395ug/L10

 Sample ID:   609113     Sample Date:  07/03/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 609113    ISOTECH ID: 726055
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.683MOL %0.005
SOPBRITISH THERMAL UNITS341BTU
SOPBUTANE0.465MOL %0.0001
SOPC6+ (hexanes +)0.252MOL %0.0001
SOPCARBON DIOXIDE0.076MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.93
SOPDELTA 13C C2-31.2
SOPDELTA 13C C3-28.07
SOPDELTA 13C iC4-31.12
SOPDelta 13C iC5-28.66
SOPDELTA 13C nC4-27.6
SOPDelta 13C nC5-27.33
SOPDELTA D C1-225.3
SOPETHANE3.39MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.33MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.2MOL %0.0001
SOPISOPENTANE0.119MOL %0.0001
SOPMETHANE20.16MOL %0.0002
SOPNITROGEN (N2)57.58MOL %0.01
SOPOXYGEN (O2)15.35MOL %0.01
SOPPENTANE0.112MOL %0.0001
SOPPROPANE1.28MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.93RATIO_AIR

 Sample ID:   609109     Sample Date:  07/03/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 609109    ISOTECH ID: 725995
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.623MOL %0.005
SOPBRITISH THERMAL UNITS696BTU
SOPBUTANE0.514MOL %0.0001
SOPC6+ (hexanes +)0.0506MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-57.19
SOPDELTA 13C C2-30.64
SOPDELTA 13C C3-27.66
SOPDELTA D C1-247.9
SOPETHANE5.88MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.81NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.24MOL %0.0001
SOPISOPENTANE0.0552MOL %0.0001
SOPMETHANE47.65MOL %0.0002
SOPNITROGEN (N2)31.07MOL %0.01
SOPOXYGEN (O2)10.81MOL %0.01
SOPPENTANE0.0459MOL %0.0001
SOPPROPANE3.06MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.819RATIO_AIR

 Sample ID:   609110     Sample Date:  07/03/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 609110    ISOTECH ID: 725995
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.33mg/L0.01
SOPETHANE2.5mg/L0.0002
SOPMETHANE10mg/L0.0002
SOPNITROGEN (N2)10mg/L0.02
SOPPROPANE1.8mg/L0.0003

 Sample ID:   609111     Sample Date:  07/03/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 609111    Accutest ID: DA17310-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.956mg/L0.05
E200.7CALCIUM3.53mg/L0.4
E200.7IRON0.0444mg/L0.01
E200.7MAGNESIUMNDmg/L0.2U
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUM2.72mg/L1
E200.7SODIUM364mg/L0.4
E200.7STRONTIUM0.181mg/L0.005
E200.8BARIUM0.063mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE5mg/L0.25
E300.0CHLORIDE548mg/L25
E300.0FLUORIDE3.8mg/L0.5
E300.0NITRATENDmg/L0.05U
E300.0Nitrite as NO2NDmg/L0.2U
E300.0SULFATENDmg/L2.5U
FIELDpH, FIELD9.9SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1330UMHOS/CM0.5
FIELDTEMPERATURE, FIELD28.9degrees C
RSK175ETHANE1.32mg/L0.04
RSK175METHANE4.11mg/L0.02
RSK175PROPANE1.08mg/L0.055
SM1030CATION - ANION BALANCE2.7%
SM2320BBICARBONATE ALKALINITY as CACO324.2mg/L5
SM2320BCARBONATE ALKALINITY AS CACO352.6mg/L5
SM2320BTOTAL ALKALINITY AS CACO376.8mg/L5
SM2510BSPECIFIC CONDUCTIVITY1920UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS1020mg/L10
SM4500-H+ BpH, FIELD9.76SU
SW8015TEPH DIESEL RANGE ORGANICS1.83mg/L0.19
SW8015TVPH - Gasoline Range Organics2.84mg/L0.05
SW8260BENZENE110ug/L10
SW8260ETHYLBENZENE33.6ug/L10
SW8260M-+P-XYLENE258ug/L10
SW8260o-XYLENE105ug/L10
SW8260TOLUENE429ug/L10
SW8260TOTAL XYLENES363ug/L10

 Sample ID:   609112     Sample Date:  07/03/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 609112    Accutest ID: DA17311-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U