COGIS - Environmental Sample Site Information

 
#448974 Information View DocsDoc View GISGIS
Sample Site ID448974
FacilityTypeOGProj Number
CountyJACKSON - 057LocationLot 1 7 7N80W
Elevation8130Lat/Long40.597736/-106.425178
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-057-06597Well Name:Peters 0781 16-12H13
Well Status:PROperator Name:FULCRUM ENERGY OPERATING LLC
Location:LOT1  7  7N  80W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   645957     Sample Date:  12/13/2022     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 645957    SPL ID: 22120129-012A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.0025MOL %
GPA 2286BENZENE0.0078MOL %
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1228.7BTU/cuft
GPA 2286BUTANE2.1054MOL %
GPA 2286C11 (mixed isomers)MOL %
GPA 2286C12 (mixed isomers)MOL %
GPA 2286C13 (mixed isomers)MOL %
GPA 2286CARBON DIOXIDE2.4615MOL %
GPA 2286CYCLOHEXANE0.0331MOL %
GPA 2286Decane0.0017MOL %
GPA 2286Decanes (mixed isomers)MOL %
GPA 2286ETHENE6.2026MOL %
GPA 2286ETHYLBENZENE0.0069MOL %
GPA 2286Heptane0.0427MOL %
GPA 2286ISOBUTANE0.6271MOL %
GPA 2286ISOPENTANE0.4485MOL %
GPA 2286METHANE79.5253MOL %
GPA 2286N-HEXANE0.1157MOL %
GPA 2286n-octane0.0196MOL %
GPA 2286NITROGEN (N2)1.7797MOL %
GPA 2286NONANE0.0028MOL %
GPA 2286Other Heptanes0.2123MOL %
GPA 2286Other Hexanes0.1961MOL %
GPA 2286Other Nonanes0.0167MOL %
GPA 2286Other Octanes0.1209MOL %
GPA 2286PENTANE0.4911MOL %
GPA 2286PROPANE5.5248MOL %
GPA 2286SPECIFIC GRAVITY0.7516RATIO_AIR
GPA 2286Tetradecanes +MOL %
GPA 2286TOLUENE0.0111MOL %
GPA 2286TOTAL XYLENES0.0129MOL %

 Sample ID:   620271     Sample Date:  10/20/2020     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 620271    SPL ID: 20100219-016A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1258.4BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1280.6BTU/cuft dry
GPA 2261-13BUTANE2.6755MOL %
GPA 2261-13C6+ (hexanes +)0.7218MOL %
GPA 2261-13CARBON DIOXIDE2.1577MOL %
GPA 2261-13ETHANE6.0362MOL %
GPA 2261-13ISOBUTANE0.7767MOL %
GPA 2261-13ISOPENTANE0.6669MOL %
GPA 2261-13METHANE77.9416MOL %
GPA 2261-13NITROGEN (N2)1.7901MOL %
GPA 2261-13PENTANE0.4784MOL %
GPA 2261-13PROPANE6.0959MOL %
GPA 2261-13SPECIFIC GRAVITY0.7804Ratio

 Sample ID:   631443     Sample Date:  10/05/2021     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 631443    SPL ID: CO 04R0046
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1212.3BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1233.7BTU/cuft dry
GPA 2261-13BUTANE2.3903MOL %
GPA 2261-13C6+ (hexanes +)0.5603MOL %
GPA 2261-13CARBON DIOXIDE2.8673MOL %
GPA 2261-13ETHANE6.1302MOL %
GPA 2261-13ISOBUTANE0.6912MOL %
GPA 2261-13ISOPENTANE0.5447MOL %
GPA 2261-13METHANE78.8492MOL %
GPA 2261-13NITROGEN (N2)1.5707MOL %
GPA 2261-13PENTANE0.2951MOL %
GPA 2261-13PROPANE5.7598MOL %
GPA 2261-13SPECIFIC GRAVITY0.7591Ratio

 Sample ID:   602328     Sample Date:  08/26/2018     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  Paragon Automation

Sample Results for Sample # 602328    Paragon Automation ID: Peters 16-12 H13
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS1379BTU/cuft
GPA 2261-13BUTANE4.09MOL %PRSNT
GPA 2261-13CARBON DIOXIDE2.11MOL %PRSNT
GPA 2261-13ETHANE7.67MOL %PRSNT
GPA 2261-13HEPTANES, MIXED ISOMERS0.38MOL %PRSNT
GPA 2261-13ISOBUTANE1.12MOL %PRSNT
GPA 2261-13ISOPENTANE0.87MOL %PRSNT
GPA 2261-13METHANE70.37MOL %PRSNT
GPA 2261-13N-HEXANE0.57MOL %PRSNT
GPA 2261-13n-octane0.095MOL %PRSNT
GPA 2261-13NITROGEN (N2)2.82MOL %PRSNT
GPA 2261-13NONANE0.005MOL %PRSNT
GPA 2261-13PENTANE1.03MOL %PRSNT
GPA 2261-13PROPANE8.87MOL %PRSNT
GPA 2261-13SPECIFIC GRAVITY0.853RATIO_AIR

 Sample ID:   661559     Sample Date:  07/24/2024     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 661559    Dolan Integration Group ID: DIG-036358
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %0.282%
CALCcarbon preference index (Hunt)1.113Ratio
CALCcarbon preference index (Marzi)1.128Ratio
CALCcycloparaffins %0.228%
CALCisoparaffins % (branched)0.304%
CALCisoprenoids %8.272%
CALCn paraffin %29.809%
CALCnC17/(nC18+nC29) ratio0.993Ratio
CALCnC18/(nC18+nC19) ratio0.564Ratio
CALCphytane/nC18 ratio0.466Ratio
CALCpristane/nC17 ratio0.54Ratio
CALCpristane/phytane ratio1.45Ratio
CALCresolved unknowns %59.056%
G02G1,1,3-TrimethylcyclopentaneNDAREA COUNT1ND
G02G1,1,3-TrimethylcyclopentaneNDppm10ND
G02G1,1-dimethylcyclopentaneNDAREA COUNT1ND
G02G1,1-dimethylcyclopentaneNDppm10ND
G02G1,2,3-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,3-trimethylcyclopentaneNDppm10ND
G02G1,2,4-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,4-trimethylcyclopentaneNDppm10ND
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentaneNDAREA COUNT1ND
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,3-DIMETHYLBUTANENDppm10ND
G02G2,3-dimethylpentaneNDAREA COUNT1ND
G02G2,3-dimethylpentaneNDppm10ND
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-methylhexaneNDAREA COUNT1ND
G02G2-methylhexaneNDppm10ND
G02G2-METHYLPENTANENDAREA COUNT1ND
G02G2-METHYLPENTANENDppm10ND
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexaneNDAREA COUNT1ND
G02G3-methylhexaneNDppm10ND
G02G3-METHYLPENTANENDAREA COUNT1ND
G02G3-METHYLPENTANENDppm10ND
G02GBENZENENDAREA COUNT1ND
G02GBENZENENDppm10ND
G02GBUTANE2.214AREA COUNT1
G02GBUTANE173ppm10
G02Gcis-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gcis-1,3-dimethylcyclopentaneNDppm10ND
G02GCYCLOHEXANENDAREA COUNT1ND
G02GCYCLOHEXANENDppm10ND
G02GCYCLOPENTANENDAREA COUNT1ND
G02GCYCLOPENTANENDppm10ND
G02GDecane112.17AREA COUNT1
G02GDecane8977ppm10
G02GETHYLBENZENE2.021AREA COUNT1
G02GETHYLBENZENE159ppm10
G02GethylcyclopentaneNDAREA COUNT1ND
G02GethylcyclopentaneNDppm10ND
G02GHeptane1.801AREA COUNT1
G02GHeptane143ppm10
G02GHEXANES1.067AREA COUNT1
G02GHEXANES85ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANENDAREA COUNT1ND
G02GISOBUTANENDppm10ND
G02GISOPENTANE0.79AREA COUNT1
G02GISOPENTANE61ppm10
G02Gisoprenoid C1017.969AREA COUNT1
G02Gisoprenoid C101438ppm10
G02Gisoprenoid C1137.708AREA COUNT1
G02Gisoprenoid C113021ppm10
G02Gisoprenoid C1371.674AREA COUNT1
G02Gisoprenoid C135754ppm10
G02Gisoprenoid C1460.607AREA COUNT1
G02Gisoprenoid C144870ppm10
G02Gisoprenoid C1553.182AREA COUNT1
G02Gisoprenoid C154278ppm10
G02Gisoprenoid C1671.862AREA COUNT1
G02Gisoprenoid C165780ppm10
G02Gisoprenoid C1867.69AREA COUNT1
G02Gisoprenoid C185450ppm10
G02Gisoprenoid C92.74AREA COUNT1
G02Gisoprenoid C9219ppm10
G02Gm-XYLENE6.317AREA COUNT1
G02Gm-XYLENE493ppm10
G02GMETHYL CYCLOHEXANE4.389AREA COUNT1
G02GMETHYL CYCLOHEXANE356ppm10
G02GMETHYLCYCLOPENTANE1.231AREA COUNT1
G02GMETHYLCYCLOPENTANE100ppm10
G02Gn-C11216.522AREA COUNT1
G02Gn-C1117346ppm10
G02Gn-C12201.974AREA COUNT1
G02Gn-C1216197ppm10
G02Gn-C13199.931AREA COUNT1
G02Gn-C1316049ppm10
G02Gn-C14183.057AREA COUNT1
G02Gn-C1414710ppm10
G02Gn-C15174.446AREA COUNT1
G02Gn-C1514032ppm10
G02Gn-C16162.663AREA COUNT1
G02Gn-C1613084ppm10
G02Gn-C17144.5AREA COUNT1
G02Gn-C1711635ppm10
G02Gn-C18115.405AREA COUNT1
G02Gn-C189292ppm10
G02Gn-C1989.172AREA COUNT1
G02Gn-C197180ppm10
G02Gn-C2078.229AREA COUNT1
G02Gn-C206304ppm10
G02Gn-C2149.669AREA COUNT1
G02Gn-C214004ppm10
G02Gn-C2235.406AREA COUNT1
G02Gn-C222855ppm10
G02Gn-C2320.632AREA COUNT1
G02Gn-C231664ppm10
G02Gn-C2412.148AREA COUNT1
G02Gn-C24980ppm10
G02Gn-C256.205AREA COUNT1
G02Gn-C25501ppm10
G02Gn-C264.453AREA COUNT1
G02Gn-C26359ppm10
G02Gn-C272.834AREA COUNT1
G02Gn-C27229ppm10
G02Gn-C281.776AREA COUNT1
G02Gn-C28143ppm10
G02Gn-C291.091AREA COUNT1
G02Gn-C2988ppm10
G02Gn-C30NDAREA COUNT1ND
G02Gn-C30NDppm10ND
G02Gn-C31NDAREA COUNT1ND
G02Gn-C31NDppm10ND
G02Gn-c32NDAREA COUNT1ND
G02Gn-c32NDppm10ND
G02Gn-C33NDAREA COUNT1ND
G02Gn-C33NDppm10ND
G02Gn-C34NDAREA COUNT1ND
G02Gn-C34NDppm10ND
G02Gn-C35NDAREA COUNT1ND
G02Gn-C35NDppm10ND
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane5.628AREA COUNT1
G02Gn-octane449ppm10
G02GNormal Alkane C932.881AREA COUNT1
G02GNormal Alkane C92626ppm10
G02Go-XYLENE5.532AREA COUNT1
G02Go-XYLENE440ppm10
G02Gp-XYLENE2.267AREA COUNT1
G02Gp-XYLENE184ppm10
G02GPENTANE1.19AREA COUNT1
G02GPENTANE94ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane53.828AREA COUNT1
G02Gphytane4338ppm10
G02Gpristane78.074AREA COUNT1
G02Gpristane6286ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE1.439AREA COUNT1
G02GTOLUENE109ppm10
G02Gtrans-1,2-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,2-dimethylcyclopentaneNDppm10ND
G02Gtrans-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,3-dimethylcyclopentaneNDppm10ND

 Sample ID:   602339     Sample Date:  07/13/2018     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 602339    SPL ID: 18070053-001B
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.006MOL %0.001
GPA 2286BENZENE0.02MOL %0.001
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1489.1BTU/cuft
GPA 2286BUTANE4.832MOL %0.001
GPA 2286C11 (mixed isomers)0.002MOL %0.001
GPA 2286C12 (mixed isomers)0MOL %0.001
GPA 2286C13 (mixed isomers)0MOL %0.001
GPA 2286CARBON DIOXIDE2.476MOL %0.001
GPA 2286CYCLOHEXANE0.089MOL %0.001
GPA 2286Decane0.002MOL %0.001
GPA 2286Decanes (mixed isomers)0.028MOL %0.001
GPA 2286ETHANE9.072MOL %0.001
GPA 2286ETHYLBENZENE0.008MOL %0.001
GPA 2286HEPTANES, MIXED ISOMERS0.109MOL %0.001
GPA 2286ISOBUTANE1.448MOL %0.001
GPA 2286ISOPENTANE1.143MOL %0.001
GPA 2286METHANE62.339MOL %0.001
GPA 2286N-HEXANE0.32MOL %0.001
GPA 2286n-octane0.034MOL %0.001
GPA 2286NITROGEN (N2)4.27MOL %0.001
GPA 2286NONANE0.01MOL %0.001
GPA 2286Other Heptanes0.562MOL %0.001
GPA 2286Other Hexanes0.532MOL %0.001
GPA 2286Other Nonanes0.088MOL %0.001
GPA 2286Other Octanes0.287MOL %0.001
GPA 2286PENTANE1.253MOL %0.001
GPA 2286PROPANE11.024MOL %0.001
GPA 2286SPECIFIC GRAVITY0.9466RATIO_AIR
GPA 2286Tetradecanes +0MOL %0.001
GPA 2286TOLUENE0.026MOL %0.001
GPA 2286TOTAL XYLENES0.02MOL %0.001

 Sample ID:   566913     Sample Date:  07/13/2018     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 566913    SPL ID: 500-18070053-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBUTANE9.747MOL %
SOPCARBON DIOXIDE0.313MOL %
SOPETHANE2.508MOL %
SOPHeptanes+52.232MOL %
SOPHEXANES9.299MOL %
SOPISOBUTANE2.156MOL %
SOPISOPENTANE4.649MOL %
SOPMETHANE4.336MOL %
SOPNITROGEN (N2)0.107MOL %
SOPPENTANE6.308MOL %
SOPPROPANE8.346MOL %

 Sample ID:   669160     Sample Date:  07/01/2025     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  Alliance Technical Group

Sample Results for Sample # 669160    Alliance Technical Group ID: Grizzly Hebron - Peters 16-12
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0MOL %0.001
GPA 2286BENZENE0.0063MOL %0.001
GPA 2286BUTANE2.1434MOL %0.02
GPA 2286CARBON DIOXIDE2.4248MOL %0.02
GPA 2286CYCLOHEXANE0.0067MOL %0.001
GPA 2286CYCLOPENTANE0.0729MOL %0.001
GPA 2286DECANES +0MOL %0.001
GPA 2286ETHANE4.8741MOL %0.02
GPA 2286ETHYLBENZENE0.0002MOL %0.001
GPA 2286Heptane0.0121MOL %0.001
GPA 2286HYDROGEN SULFIDE0MOL %0.05
GPA 2286ISOBUTANE0.6289MOL %0.02
GPA 2286ISOPENTANE0.5493MOL %0.02
GPA 2286METHANE80.9851MOL %0.02
GPA 2286METHYL CYCLOHEXANE0.0036MOL %0.001
GPA 2286N-HEXANE0.1474MOL %0.001
GPA 2286NITROGEN (N2)2.1179MOL %0.02
GPA 2286NONANE0.0009MOL %0.001
GPA 2286OCTANE, MIXED ISOMERS0.0057MOL %0.001
GPA 2286Other Hexanes0.3273MOL %0.001
GPA 2286OXYGEN + ARGON0.0287MOL %0.02
GPA 2286PENTANE0.5879MOL %0.02
GPA 2286PROPANE5.0762MOL %0.04
GPA 2286TOLUENE0.0005MOL %0.001
GPA 2286TOTAL XYLENES0.0003MOL %0.001

 Sample ID:   666497     Sample Date:  03/19/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 666497    Pace Analytical ID: L1838167-01
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E904.0228RADIUM23.1pCi/L0.365
SM7500-RN-B226RADIUM82.9pCi/L0.157

 Sample ID:   666498     Sample Date:  03/19/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 666498    Pace Analytical ID: L1838165-01
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E365.4PHOSPHORUS0.144mg/L0.1
RSK-175ETHANE1.94mg/L0.013
RSK-175ETHENENDmg/L0.013U
RSK-175METHANE7.31mg/L0.1
SM2320BBICARBONATE ALKALINITY as CACO3635mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L20U
SM2320BTOTAL ALKALINITY AS CACO3635mg/L20
SM2540CTOTAL DISSOLVED SOLIDS39800mg/L1000
SM2540DTOTAL SUSPENDED SOLIDS64.5mg/L6.25
SM4500-P-EORTHOPHOSPHATE0.308mg/L0.03
SW6010BARIUM106mg/L0.025
SW6010BORON21.7mg/L1
SW6010CALCIUM535mg/L5
SW6010IRON42.4mg/L0.5
SW6010MAGNESIUM70.9mg/L5
SW6010MANGANESE0.491mg/L0.05
SW6010POTASSIUM62.9mg/L10
SW6010SELENIUMNDmg/L0.05U
SW6010SODIUM13800mg/L60
SW6010STRONTIUM99.6mg/L0.2
SW8015C10-C28 Diesel Range Organics10.9mg/L1
SW8015C28-C36 Motor Oil Range Organics4.75mg/L1
SW8015TVPH - Gasoline Range Organics14.3mg/L2.5
SW846 8260BBENZENE2.71mg/L0.1
SW846 8260BETHYLBENZENE0.209mg/L0.025
SW846 8260BNAPHTHALENENDmg/L0.125U
SW846 8260BTOLUENE2.14mg/L0.025
SW846 8260BTOTAL XYLENES0.818mg/L0.075
SW9040PH, LAB6.92SUT8
SW9050SPECIFIC CONDUCTIVITY64800umhos/cm10
SW9056BROMIDE308mg/L50
SW9056CHLORIDE24100mg/L500
SW9056FLUORIDENDmg/L7.5U
SW9056NITRATENDmg/L5U
SW9056NITRITENDmg/L5U
SW9056SULFATENDmg/L250U