Sample ID: 663442 Sample Date: 8/28/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: AccutestSample Results for Sample # 663442 Accutest ID: DA66807-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | E200.8 | BARIUM | 0.153 | mg/L | 0.002 | | E200.8 | BORON | 0.518 | mg/L | 0.04 | | E200.8 | CALCIUM | 58.1 | mg/L | 2 | | E200.8 | IRON | 2.45 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 4.37 | mg/L | 0.1 | | E200.8 | MANGANESE | 1.25 | mg/L | 0.001 | | E200.8 | POTASSIUM | 3.89 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 444 | mg/L | 10 | | E200.8 | STRONTIUM | 1.19 | mg/L | 0.1 | | E300.0 | BROMIDE | 4.4 | mg/L | 2.5 | | E300.0 | CHLORIDE | 252 | mg/L | 25 | | E300.0 | FLUORIDE | 91.1 | mg/L | 5 | | E300.0 | NITRATE | ND | mg/L | 0.5 | U | E300.0 | NITRITE | ND | mg/L | 0.2 | U | E300.0 | SULFATE | ND | mg/L | 1 | U | FIELD | pH, FIELD | 7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1900 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 23.4 | degrees C | | | SM1030 | CATION - ANION BALANCE | 7.4 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 379 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 5 | U | SM2320B | TOTAL ALKALINITY AS CACO3 | 379 | mg/L | 5 | | SW8015 | TVPH - Gasoline Range Organics | 19.1 | mg/L | 1 | | SW8260 | BENZENE | 236 | ug/L | 20 | | SW8260 | ETHYLBENZENE | 54.3 | ug/L | 20 | | SW8260 | M-+P-XYLENE | 637 | ug/L | 20 | | SW8260 | o-XYLENE | 156 | ug/L | 20 | | SW8260 | TOLUENE | 1170 | ug/L | 20 | | SW8260 | TOTAL XYLENES | 792 | ug/L | 20 | |
Sample ID: 663443 Sample Date: 8/28/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 663443 Accutest ID: DA66809-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 663433 Sample Date: 8/27/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: AccutestSample Results for Sample # 663433 Accutest ID: DA66770-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | E200.8 | BARIUM | 0.545 | mg/L | 0.002 | | E200.8 | BORON | 4.96 | mg/L | 0.2 | | E200.8 | CALCIUM | 66.6 | mg/L | 2 | | E200.8 | IRON | 1.45 | mg/L | 0.02 | | E200.8 | MAGNESIUM | ND | mg/L | 0.5 | U | E200.8 | MANGANESE | 0.0591 | mg/L | 0.001 | | E200.8 | POTASSIUM | 18.2 | mg/L | 1 | | E200.8 | SELENIUM | 0.002 | mg/L | 0.0004 | | E200.8 | SODIUM | 1490 | mg/L | 50 | | E200.8 | STRONTIUM | 1.68 | mg/L | 0.1 | | E300.0 | BROMIDE | ND | mg/L | 2.5 | U | E300.0 | CHLORIDE | 524 | mg/L | 25 | | E300.0 | FLUORIDE | 51.3 | mg/L | 5 | | E300.0 | NITRATE | 0.72 | mg/L | 0.5 | | E300.0 | NITRITE | ND | mg/L | 0.2 | U | E300.0 | SULFATE | 610 | mg/L | 25 | | FIELD | pH, FIELD | 9.4 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 53600 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 31.7 | degrees C | | | SM1030 | CATION - ANION BALANCE | 22.5 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 447 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 214 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 662 | mg/L | 5 | | SW8015 | TVPH - Gasoline Range Organics | 21 | mg/L | 5 | | SW8260 | BENZENE | ND | ug/L | 1000 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1000 | U | SW8260 | M-+P-XYLENE | 2650 | ug/L | 1000 | | SW8260 | o-XYLENE | ND | ug/L | 1000 | U | SW8260 | TOLUENE | ND | ug/L | 1000 | U | SW8260 | TOTAL XYLENES | 2650 | ug/L | 1000 | |
Sample ID: 663434 Sample Date: 8/27/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 663434 Accutest ID: DA66774-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 663136 Sample Date: 8/6/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: AccutestSample Results for Sample # 663136 Accutest ID: DA66190-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | E200.8 | BARIUM | 0.0325 | mg/L | 0.002 | | E200.8 | BORON | 1.17 | mg/L | 0.04 | | E200.8 | CALCIUM | 0.588 | mg/L | 0.4 | | E200.8 | IRON | 0.694 | mg/L | 0.02 | | E200.8 | MAGNESIUM | ND | mg/L | 0.1 | U | E200.8 | MANGANESE | 0.0051 | mg/L | 0.001 | | E200.8 | POTASSIUM | 85.5 | mg/L | 2 | | E200.8 | SELENIUM | 0.00047 | mg/L | 0.0004 | | E200.8 | SODIUM | 865 | mg/L | 15 | | E200.8 | STRONTIUM | ND | mg/L | 0.02 | U | E300.0 | BROMIDE | ND | mg/L | 1.3 | U | E300.0 | CHLORIDE | 396 | mg/L | 13 | | E300.0 | FLUORIDE | ND | mg/L | 2.5 | U | E300.0 | NITRATE | 0.32 | mg/L | 0.25 | | E300.0 | NITRITE | ND | mg/L | 0.1 | U | E300.0 | SULFATE | 461 | mg/L | 13 | | FIELD | pH, FIELD | 10.9 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 3830 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 23.5 | degrees C | | | SW8015 | TVPH - Gasoline Range Organics | 9.38 | mg/L | 0.5 | | SW8260 | BENZENE | 127 | ug/L | 5 | | SW8260 | ETHYLBENZENE | 19.8 | ug/L | 5 | | SW8260 | M-+P-XYLENE | 177 | ug/L | 5 | | SW8260 | o-XYLENE | 67.5 | ug/L | 5 | | SW8260 | TOLUENE | 241 | ug/L | 5 | | SW8260 | TOTAL XYLENES | 244 | ug/L | 5 | |
Sample ID: 663137 Sample Date: 8/6/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 663137 Accutest ID: DA66195-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 662720 Sample Date: 7/18/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 662720 Accutest ID: DA65798-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 661573 Sample Date: 6/6/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: AccutestSample Results for Sample # 661573 Accutest ID: DA64828-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | E200.8 | BARIUM | 0.048 | mg/L | 0.002 | | E200.8 | BORON | 1.53 | mg/L | 0.04 | | E200.8 | CALCIUM | 5.93 | mg/L | 0.4 | | E200.8 | IRON | 0.0723 | mg/L | 0.02 | | E200.8 | MAGNESIUM | ND | mg/L | 0.1 | U | E200.8 | MANGANESE | ND | mg/L | 0.001 | U | E200.8 | POTASSIUM | 41.2 | mg/L | 1 | | E200.8 | SELENIUM | 0.0024 | mg/L | 0.0004 | | E200.8 | SODIUM | 714 | mg/L | 10 | | E200.8 | STRONTIUM | 0.25 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.91 | mg/L | 0.5 | | E300.0 | CHLORIDE | 253 | mg/L | 50 | | E300.0 | FLUORIDE | 3.1 | mg/L | 1 | | E300.0 | NITRATE | 1.2 | mg/L | 0.1 | | E300.0 | NITRITE | ND | mg/L | 0.4 | U | E300.0 | SULFATE | 347 | mg/L | 50 | | FIELD | pH, FIELD | 12.2 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 5350 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 22.3 | degrees C | | | SW8015 | TVPH - Gasoline Range Organics | 2.7 | mg/L | 0.5 | | SW8260 | BENZENE | 41.6 | ug/L | 10 | | SW8260 | ETHYLBENZENE | 32.7 | ug/L | 10 | | SW8260 | M-+P-XYLENE | 326 | ug/L | 10 | | SW8260 | o-XYLENE | 135 | ug/L | 10 | | SW8260 | TOLUENE | 227 | ug/L | 10 | | SW8260 | TOTAL XYLENES | 461 | ug/L | 10 | |
Sample ID: 657994 Sample Date: 1/22/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 657994 Accutest ID: DA61412-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|