Sample ID: 645750 Sample Date: 11/02/2022 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 645750 ISOTECH ID: 848826 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1275 | BTU | | | | SOP | BUTANE | 1.92 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.151 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.56 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.4 | ‰ | | | | SOP | DELTA 13C C2 | -30.24 | ‰ | | | | SOP | DELTA 13C C3 | -27.36 | ‰ | | | | SOP | DELTA 13C CO2 | 3.63 | ‰ | | | | SOP | DELTA 13C iC4 | -30.68 | ‰ | | | | SOP | Delta 13C iC5 | -28.4 | ‰ | | | | SOP | DELTA 13C nC4 | -26.98 | ‰ | | | | SOP | Delta 13C nC5 | -26.75 | ‰ | | | | SOP | DELTA D C1 | -223.5 | ‰ | | | | SOP | ETHANE | 12.98 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0002 | MOL % | 0.0001 | | | SOP | Helium | 0.0066 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.155 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.949 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.6 | MOL % | 0.0001 | | | SOP | METHANE | 74.28 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.25 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | ND | MOL % | 0.01 | ND | | SOP | PENTANE | 0.536 | MOL % | 0.0001 | | | SOP | PROPANE | 5.61 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.763 | RATIO_AIR | | |
Sample ID: 645748 Sample Date: 11/02/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 645748 ISOTECH ID: 849003 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.673 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 604 | BTU | | | | SOP | BUTANE | 0.594 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0775 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | 0.09 | MOL % | 0.01 | | | SOP | DELTA 13C C1 | -48.86 | ‰ | | | | SOP | DELTA 13C C2 | -31.24 | ‰ | | | | SOP | DELTA 13C C3 | -28.9 | ‰ | | | | SOP | DELTA 13C iC4 | -31.3 | ‰ | | | | SOP | Delta 13C iC5 | -28.2 | ‰ | | | | SOP | DELTA 13C nC4 | -27.7 | ‰ | | | | SOP | Delta 13C nC5 | -26.6 | ‰ | | | | SOP | DELTA D C1 | -226.2 | ‰ | | | | SOP | ETHANE | 6.44 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0012 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.84 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.244 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0966 | MOL % | 0.0001 | | | SOP | METHANE | 37.97 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 38.43 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 12.67 | MOL % | 0.01 | | | SOP | PENTANE | 0.0898 | MOL % | 0.0001 | | | SOP | PROPANE | 2.62 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0012 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.863 | RATIO_AIR | | |
Sample ID: 645749 Sample Date: 11/02/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 645749 ISOTECH ID: 849003 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.46 | mg/L | 0.02 | | | SOP | ETHANE | 3.5 | mg/L | 0.0003 | | | SOP | METHANE | 10 | mg/L | 0.0003 | | | SOP | NITROGEN (N2) | 17 | mg/L | 0.03 | | | SOP | PROPANE | 2 | mg/L | 0.0005 | |
Sample ID: 642936 Sample Date: 08/09/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 642936 ISOTECH ID: 838186 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.881 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 528 | BTU | | | | SOP | BUTANE | 0.439 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0634 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.57 | ‰ | | | | SOP | DELTA 13C C2 | -31.09 | ‰ | | | | SOP | DELTA 13C C3 | -28.79 | ‰ | | | | SOP | DELTA 13C iC4 | -31.4 | ‰ | | | | SOP | Delta 13C iC5 | -28.2 | ‰ | | | | SOP | DELTA 13C nC4 | -27.8 | ‰ | | | | SOP | Delta 13C nC5 | -26.6 | ‰ | | | | SOP | DELTA D C1 | -221.8 | ‰ | | | | SOP | ETHANE | 5.49 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0011 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.81 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.19 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0608 | MOL % | 0.0001 | | | SOP | METHANE | 34.15 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 41.57 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 14.89 | MOL % | 0.01 | | | SOP | PENTANE | 0.0555 | MOL % | 0.0001 | | | SOP | PROPANE | 2.21 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0011 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.876 | RATIO_AIR | | |
Sample ID: 642940 Sample Date: 08/09/2022 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 642940 ISOTECH ID: 838727 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1309 | BTU | | | | SOP | BUTANE | 2.21 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.321 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.49 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.8 | ‰ | | | | SOP | DELTA 13C C2 | -30.3 | ‰ | | | | SOP | DELTA 13C C3 | -27.4 | ‰ | | | | SOP | DELTA 13C CO2 | 3.6 | ‰ | | | | SOP | DELTA 13C iC4 | -30.8 | ‰ | | | | SOP | Delta 13C iC5 | -28.6 | ‰ | | | | SOP | DELTA 13C nC4 | -27.1 | ‰ | | | | SOP | Delta 13C nC5 | -27 | ‰ | | | | SOP | DELTA D C1 | -230 | ‰ | | | | SOP | ETHANE | 12.94 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0002 | MOL % | 0.0001 | | | SOP | Helium | 0.0084 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.18 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 1.04 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.847 | MOL % | 0.0001 | | | SOP | METHANE | 73.1 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.26 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.023 | MOL % | 0.01 | | | SOP | PENTANE | 0.821 | MOL % | 0.0001 | | | SOP | PROPANE | 5.76 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.784 | RATIO_AIR | | |
Sample ID: 642937 Sample Date: 08/09/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 642937 ISOTECH ID: 838186 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.42 | mg/L | 0.01 | | | SOP | ETHANE | 2.2 | mg/L | 0.0002 | | | SOP | METHANE | 6.6 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 12 | mg/L | 0.02 | | | SOP | PROPANE | 1.2 | mg/L | 0.0003 | |
Sample ID: 642938 Sample Date: 08/09/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 642938 Accutest ID: DA47966-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.146 | mg/L | 0.004 | | | E200.8 | BORON | 0.302 | mg/L | 0.08 | | | E200.8 | CALCIUM | 80.2 | mg/L | 0.8 | | | E200.8 | IRON | 0.0493 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.8 | MANGANESE | ND | mg/L | 0.002 | U | | E200.8 | POTASSIUM | 95.4 | mg/L | 4 | | | E200.8 | SELENIUM | 0.0011 | mg/L | 0.0008 | | | E200.8 | SODIUM | 679 | mg/L | 10 | | | E200.8 | STRONTIUM | 2.59 | mg/L | 0.1 | | | E300.0 | BROMIDE | ND | mg/L | 0.5 | U | | E300.0 | CHLORIDE | 207 | mg/L | 50 | | | E300.0 | FLUORIDE | ND | mg/L | 10 | U | | E300.0 | NITRATE | 1.2 | mg/L | 0.25 | | | E300.0 | NITRITE | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | 263 | mg/L | 50 | | | FIELD | pH, FIELD | 12.4 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 5900 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 23.7 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 4 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 221 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1090 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 74.7 | mg/L | 1 | | | SW8015 | TVPH - Gasoline Range Organics | 4.71 | mg/L | 0.25 | | | SW8260 | BENZENE | 12.9 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | 7.2 | ug/L | 5 | | | SW8260 | M-+P-XYLENE | 75.5 | ug/L | 5 | | | SW8260 | o-XYLENE | 108 | ug/L | 5 | | | SW8260 | TOLUENE | 67.1 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 183 | ug/L | 5 | |
Sample ID: 642939 Sample Date: 08/09/2022 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 642939 Accutest ID: DA47967-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 550292 Sample Date: 05/12/2016 Matrix: GAS Collection Point: PRDC Type: PRDG Lab: ISOTECH| Sample Results for Sample # 550292 ISOTECH ID: 565295 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0057 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1195 | BTU | | | | SOP | BUTANE | 0.789 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.133 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.76 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.31 | ‰ | | | | SOP | DELTA 13C C2 | -29.92 | ‰ | | | | SOP | DELTA 13C C3 | -26.95 | ‰ | | | | SOP | DELTA 13C iC4 | -30.21 | ‰ | | | | SOP | Delta 13C iC5 | -27.8 | ‰ | | | | SOP | DELTA 13C nC4 | -26.36 | ‰ | | | | SOP | Delta 13C nC5 | -25.97 | ‰ | | | | SOP | DELTA D C1 | -233 | ‰ | | | | SOP | ETHANE | 12.31 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0002 | MOL % | 0.0001 | | | SOP | Helium | 0.0091 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.335 | MOL % | 0.01 | | | SOP | ISOBUTANE | 0.502 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.16 | MOL % | 0.0001 | | | SOP | METHANE | 80.63 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.42 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.014 | MOL % | 0.01 | | | SOP | PENTANE | 0.124 | MOL % | 0.0001 | | | SOP | PROPANE | 3.81 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.685 | RATIO_AIR | | |
Sample ID: 549815 Sample Date: 05/12/2016 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 549815 Accutest ID: D82689-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 5410 | UMHOS/CM | 0.5 | | | E150.1 | PH, LAB | 11.6 | SU | | | | E170.1 | TEMPERATURE, FIELD | 28.46 | degrees C | | | | E200.7 | BORON | 0.364 | mg/L | 0.05 | | | E200.7 | CALCIUM | 81.4 | mg/L | 0.4 | | | E200.7 | IRON | 0.113 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | | E200.7 | POTASSIUM | 77.6 | mg/L | 1 | | | E200.7 | SODIUM | 570 | mg/L | 0.4 | | | E200.7 | STRONTIUM | 2.55 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.033 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.0015 | mg/L | 0.0008 | | | E300.0 | BROMIDE | ND | mg/L | 25 | U | | E300.0 | CHLORIDE | ND | mg/L | 250 | U | | E300.0 | FLUORIDE | ND | mg/L | 50 | U | | E300.0 | NITRATE | ND | mg/L | 5 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 7 | U | | E300.0 | Nitrite as NO2 | ND | mg/L | 2 | U | | E300.0 | SULFATE | 270 | mg/L | 250 | | | FIELD | TURBIDITY | 82.3 | NTU | | | | HACH | PHOSPHORUS | 1.3 | mg/L | 0.5 | | | RSK175 | ETHANE | 1.86 | mg/L | 0.032 | | | RSK175 | METHANE | 5.63 | mg/L | 0.016 | | | RSK175 | PROPANE | 1.28 | mg/L | 0.0022 | | | SM1030 | CATION - ANION BALANCE | 10.5 | % | | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1300 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 5000 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 1800 | mg/L | 10 | | | SM4500-H+ B | PH, LAB | 9.86 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 7.69 | mg/L | 2 | | | SW8015 | TVPH - Gasoline Range Organics | 6.83 | mg/L | 0.25 | | | SW8260 | BENZENE | 0.0142 | mg/L | 0.005 | | | SW8260 | ETHYLBENZENE | 0.0053 | mg/L | 0.005 | | | SW8260 | M-+P-XYLENE | 0.0503 | mg/L | 0.005 | | | SW8260 | o-XYLENE | 0.113 | mg/L | 0.005 | | | SW8260 | TOLUENE | 0.0445 | mg/L | 0.005 | | | SW8260 | TOTAL XYLENES | 0.163 | mg/L | 0.005 | |
Sample ID: 549817 Sample Date: 05/12/2016 Matrix: WATER Collection Point: Type: SMP Lab: Accutest| Sample Results for Sample # 549817 Accutest ID: D82686-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | mg/L | 0.001 | U | | SW8260 | ETHYLBENZENE | ND | mg/L | 0.001 | U | | SW8260 | M-+P-XYLENE | ND | mg/L | 0.001 | U | | SW8260 | o-XYLENE | ND | mg/L | 0.001 | U | | SW8260 | TOLUENE | ND | mg/L | 0.001 | U | | SW8260 | TOTAL XYLENES | ND | mg/L | 0.001 | U |
Sample ID: 625370 Sample Date: 05/11/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 625370 ISOTECH ID: 792179 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.396 | MOL % | 0.005 | | | SOP | ARGON | 0.53 | mg/L | 0.02 | | | SOP | BRITISH THERMAL UNITS | 821 | BTU | | | | SOP | BUTANE | 0.713 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0847 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.52 | ‰ | | | | SOP | DELTA 13C C2 | -31.21 | ‰ | | | | SOP | DELTA 13C C3 | -28.65 | ‰ | | | | SOP | DELTA 13C iC4 | -31.1 | ‰ | | | | SOP | Delta 13C iC5 | -28.2 | ‰ | | | | SOP | DELTA 13C nC4 | -27.79 | ‰ | | | | SOP | Delta 13C nC5 | -27 | ‰ | | | | SOP | DELTA D C1 | -222.5 | ‰ | | | | SOP | ETHANE | 7.25 | MOL % | 0.0001 | | | SOP | ETHANE | 7.8 | mg/L | 0.0003 | | | SOP | ETHENE | 0.0007 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.57 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.371 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.137 | MOL % | 0.0001 | | | SOP | METHANE | 30 | mg/L | 0.0003 | | | SOP | METHANE | 55.68 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 21 | mg/L | 0.02 | | | SOP | NITROGEN (N2) | 24.37 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 7.79 | MOL % | 0.01 | | | SOP | PENTANE | 0.112 | MOL % | 0.0001 | | | SOP | PROPANE | 3.09 | MOL % | 0.0001 | | | SOP | PROPANE | 4.7 | mg/L | 0.0004 | | | SOP | PROPENE | 0.0007 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.788 | RATIO_AIR | | |
Sample ID: 625372 Sample Date: 05/11/2021 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 625372 ISOTECH ID: 791920 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1234 | BTU | | | | SOP | BUTANE | 1.47 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0363 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.51 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.3 | ‰ | | | | SOP | DELTA 13C C2 | -30.4 | ‰ | | | | SOP | DELTA 13C C3 | -27.2 | ‰ | | | | SOP | DELTA 13C CO2 | 3.8 | ‰ | | | | SOP | DELTA 13C iC4 | -30.8 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -26.9 | ‰ | | | | SOP | Delta 13C nC5 | -26.7 | ‰ | | | | SOP | DELTA D C1 | -228 | ‰ | | | | SOP | ETHANE | 13.21 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0002 | MOL % | 0.0001 | | | SOP | Helium | 0.0063 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0969 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.743 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.37 | MOL % | 0.0001 | | | SOP | METHANE | 76.09 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.25 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | ND | MOL % | 0.01 | ND | | SOP | PENTANE | 0.298 | MOL % | 0.0001 | | | SOP | PROPANE | 4.92 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.736 | RATIO_AIR | | |
Sample ID: 625371 Sample Date: 05/11/2021 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 625371 Accutest ID: DA34430-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 625368 Sample Date: 05/11/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 625368 Accutest ID: DA34429-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | ND | mg/L | 0.5 | U | | E200.7 | CALCIUM | 82.6 | mg/L | 4 | | | E200.7 | IRON | 0.205 | mg/L | 0.1 | | | E200.7 | MAGNESIUM | ND | mg/L | 2 | U | | E200.7 | MANGANESE | ND | mg/L | 0.05 | U | | E200.7 | POTASSIUM | 85.9 | mg/L | 10 | | | E200.7 | SODIUM | 676 | mg/L | 4 | | | E200.7 | STRONTIUM | 2.41 | mg/L | 0.05 | | | E200.8 | BARIUM | 0.139 | mg/L | 0.02 | | | E300.0 | BROMIDE | ND | mg/L | 1.3 | U | | E300.0 | CHLORIDE | 215 | mg/L | 13 | | | E300.0 | FLUORIDE | ND | mg/L | 2.5 | U | | E300.0 | NITRATE | 0.83 | mg/L | 0.25 | | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | 264 | mg/L | 13 | | | FIELD | pH, FIELD | 11.9 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 31800 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 10.8 | degrees C | | | | RSK175 | ETHANE | 3.48 | mg/L | 0.08 | | | RSK175 | METHANE | 10.5 | mg/L | 0.04 | | | RSK175 | PROPANE | 2.14 | mg/L | 0.11 | | | SM1030 | CATION - ANION BALANCE | 3.8 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 157 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1070 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 19.8 | mg/L | 0.19 | | | SW8015 | TVPH - Gasoline Range Organics | 4.17 | mg/L | 0.25 | | | SW8260 | BENZENE | 22.2 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | 10.7 | ug/L | 5 | | | SW8260 | M-+P-XYLENE | 106 | ug/L | 5 | | | SW8260 | o-XYLENE | 149 | ug/L | 5 | | | SW8260 | TOLUENE | 84 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 254 | ug/L | 5 | |
Sample ID: 658305 Sample Date: 02/01/2024 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 658305 ISOTECH ID: 908764 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.388 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 987 | BTU | | | | SOP | BUTANE | 1.23 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.618 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.14 | ‰ | | | | SOP | DELTA 13C C2 | -30.7 | ‰ | | | | SOP | DELTA 13C C3 | -28.19 | ‰ | | | | SOP | DELTA 13C iC4 | -31.4 | ‰ | | | | SOP | Delta 13C iC5 | -28.7 | ‰ | | | | SOP | DELTA 13C nC4 | -27.2 | ‰ | | | | SOP | Delta 13C nC5 | -26.8 | ‰ | | | | SOP | DELTA D C1 | -216.8 | ‰ | | | | SOP | ETHANE | 10.81 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0011 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.82 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.441 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.309 | MOL % | 0.0001 | | | SOP | METHANE | 57.49 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 19.73 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 4.6 | MOL % | 0.01 | | | SOP | PENTANE | 0.28 | MOL % | 0.0001 | | | SOP | PROPANE | 4.1 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0011 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.807 | RATIO_AIR | | |
Sample ID: 658306 Sample Date: 02/01/2024 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 658306 ISOTECH ID: 908764 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.2 | mg/L | 0.01 | | | SOP | ETHANE | 4.5 | mg/L | 0.0002 | | | SOP | METHANE | 12 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 6.3 | mg/L | 0.02 | | | SOP | PROPANE | 2.4 | mg/L | 0.0003 | |
Sample ID: 658309 Sample Date: 02/01/2024 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 658309 ISOTECH ID: 909033 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0118 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1297 | BTU | | | | SOP | BUTANE | 2.32 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.123 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.26 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.8 | ‰ | | | | SOP | DELTA 13C C2 | -30.3 | ‰ | | | | SOP | DELTA 13C C3 | -27.7 | ‰ | | | | SOP | DELTA 13C CO2 | 4 | ‰ | | | | SOP | DELTA 13C iC4 | -30.4 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -27.1 | ‰ | | | | SOP | Delta 13C nC5 | -26.8 | ‰ | | | | SOP | DELTA D C1 | -231 | ‰ | | | | SOP | ETHANE | 13.34 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | 0.0068 | MOL % | 0.005 | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 1.12 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.58 | MOL % | 0.0001 | | | SOP | METHANE | 71.9 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 1.09 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.14 | MOL % | 0.01 | | | SOP | PENTANE | 0.464 | MOL % | 0.0001 | | | SOP | PROPANE | 6.64 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.783 | RATIO_AIR | | |
Sample ID: 658307 Sample Date: 02/01/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 658307 Accutest ID: DA61650-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.0286 | mg/L | 0.002 | | | E200.8 | BORON | 0.181 | mg/L | 0.04 | | | E200.8 | CALCIUM | 20.5 | mg/L | 0.4 | | | E200.8 | IRON | 0.112 | mg/L | 0.02 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.1 | U | | E200.8 | MANGANESE | 0.0013 | mg/L | 0.001 | | | E200.8 | POTASSIUM | 48.4 | mg/L | 2 | | | E200.8 | SELENIUM | 0.0016 | mg/L | 0.0004 | | | E200.8 | SODIUM | 284 | mg/L | 5 | | | E200.8 | STRONTIUM | 0.86 | mg/L | 0.02 | | | E300.0 | BROMIDE | ND | mg/L | 0.25 | U | | E300.0 | CHLORIDE | 86.2 | mg/L | 2.5 | | | E300.0 | FLUORIDE | 0.73 | mg/L | 0.5 | | | E300.0 | NITRATE | 0.38 | mg/L | 0.05 | | | E300.0 | NITRATE/NITRITE AS N | 0.38 | mg/L | 0.07 | | | E300.0 | NITRITE | ND | mg/L | 0.02 | U | | E300.0 | SULFATE | 106 | mg/L | 2.5 | | | FIELD | pH, FIELD | 12.2 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 2490 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 25.2 | degrees C | | | | SW8015 | TVPH - Gasoline Range Organics | 7.22 | mg/L | 0.25 | | | SW8260 | BENZENE | 37.8 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | 62.3 | ug/L | 5 | | | SW8260 | M-+P-XYLENE | 781 | ug/L | 5 | | | SW8260 | o-XYLENE | 269 | ug/L | 5 | | | SW8260 | TOLUENE | 351 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 1050 | ug/L | 5 | |
Sample ID: 658308 Sample Date: 02/01/2024 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 658308 Accutest ID: DA61652-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 666591 Sample Date: 01/30/2025 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 666591 ISOTECH ID: 955645 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.12 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1130 | BTU | | | | SOP | BUTANE | 1.7 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0894 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.087 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | 0.012 | MOL % | 0.01 | | | SOP | DELTA 13C C1 | -46.4 | ‰ | | | | SOP | DELTA 13C C2 | -30.4 | ‰ | | | | SOP | DELTA 13C C3 | -27.4 | ‰ | | | | SOP | DELTA 13C iC4 | -30.7 | ‰ | | | | SOP | Delta 13C iC5 | -28.6 | ‰ | | | | SOP | DELTA 13C nC4 | -27.2 | ‰ | | | | SOP | Delta 13C nC5 | -26.8 | ‰ | | | | SOP | DELTA D C1 | -226 | ‰ | | | | SOP | ETHANE | 11.05 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | 0.0065 | MOL % | 0.0025 | | | SOP | HYDROGEN | 0.219 | MOL % | 0.0025 | | | SOP | ISOBUTANE | 0.778 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.7 | MOL % | 0.0001 | | | SOP | METHANE | 67.17 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 10.27 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 2.75 | MOL % | 0.01 | | | SOP | PENTANE | 0.63 | MOL % | 0.0001 | | | SOP | PROPANE | 4.42 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.773 | RATIO_AIR | | |
Sample ID: 666592 Sample Date: 01/30/2025 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 666592 ISOTECH ID: 955644 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0104 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1197 | BTU | | | | SOP | BUTANE | 1.35 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0197 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.64 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.2 | ‰ | | | | SOP | DELTA 13C C2 | -30.2 | ‰ | | | | SOP | DELTA 13C C3 | -27.3 | ‰ | | | | SOP | DELTA 13C CO2 | 3.8 | ‰ | | | | SOP | DELTA 13C iC4 | -30.7 | ‰ | | | | SOP | Delta 13C iC5 | -28.2 | ‰ | | | | SOP | DELTA 13C nC4 | -27.2 | ‰ | | | | SOP | Delta 13C nC5 | -26.5 | ‰ | | | | SOP | DELTA D C1 | -225 | ‰ | | | | SOP | ETHANE | 12.14 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | 0.0062 | MOL % | 0.0025 | | | SOP | HYDROGEN | 0.0409 | MOL % | 0.0025 | | | SOP | ISOBUTANE | 0.664 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.325 | MOL % | 0.0001 | | | SOP | METHANE | 77.34 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.91 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.12 | MOL % | 0.01 | | | SOP | PENTANE | 0.236 | MOL % | 0.0001 | | | SOP | PROPANE | 4.19 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.724 | RATIO_AIR | | |
Sample ID: 666589 Sample Date: 01/30/2025 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 666589 Accutest ID: DA70201-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | ND | mg/L | 0.1 | U | | E200.8 | BORON | ND | mg/L | 2 | U | | E200.8 | CALCIUM | 42.6 | mg/L | 20 | | | E200.8 | IRON | ND | mg/L | 1 | U | | E200.8 | MAGNESIUM | ND | mg/L | 5 | U | | E200.8 | MANGANESE | ND | mg/L | 0.05 | U | | E200.8 | POTASSIUM | 62.5 | mg/L | 10 | | | E200.8 | SELENIUM | ND | mg/L | 0.02 | U | | E200.8 | SODIUM | 425 | mg/L | 25 | | | E200.8 | STRONTIUM | 1.31 | mg/L | 1 | | | E300.0 | BROMIDE | ND | mg/L | 25 | U | | E300.0 | CHLORIDE | ND | mg/L | 250 | U | | E300.0 | FLUORIDE | ND | mg/L | 10 | U | | E300.0 | NITRATE | ND | mg/L | 5 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 7 | U | | E300.0 | NITRITE | ND | mg/L | 2 | U | | E300.0 | SULFATE | ND | mg/L | 250 | U | | FIELD | pH, FIELD | 12 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1020 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 7.4 | degrees C | | | | SW8015 | TVPH - Gasoline Range Organics | 1.44 | mg/L | 0.25 | | | SW8260 | BENZENE | 14.4 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | ND | ug/L | 5 | U | | SW8260 | M-+P-XYLENE | 26.5 | ug/L | 5 | | | SW8260 | o-XYLENE | 36.9 | ug/L | 5 | | | SW8260 | TOLUENE | 22.8 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 63.4 | ug/L | 5 | |
Sample ID: 666590 Sample Date: 01/30/2025 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 666590 Accutest ID: DA70202-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|