Sample Site ID249035
FacilityTypeOGProj Number
CountyWELD - 123LocationNWSE 6 3N66W
Elevation4786Lat/Long40.25153/-104.81832
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-16837Well Name:THOMPSON 33-6A
Well Status:SIOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWSE  6  3N  66W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   663440     Sample Date:  8/28/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 663440    ISOTECH ID: 936218
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.733MOL %0.005
SOPBRITISH THERMAL UNITS720BTU
SOPBUTANE1.87MOL %0.0001
SOPC6+ (hexanes +)0.244MOL %0.0001
SOPCARBON DIOXIDE1.92MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-52.15
SOPDELTA 13C C2-31.61
SOPDELTA 13C C3-27.56
SOPDELTA 13C CO219.5
SOPDELTA 13C iC4-30.3
SOPDelta 13C iC5-27.6
SOPDELTA 13C nC4-25.9
SOPDelta 13C nC5-25.6
SOPDELTA D C1-229.1
SOPETHANE7.11MOL %0.0001
SOPETHENE0.0039MOL %0.0001
SOPHELIUM DILUTION FACTOR0.82NA
SOPHYDROGENNDMOL %0.0025ND
SOPISOBUTANE0.917MOL %0.0001
SOPISOPENTANE0.415MOL %0.0001
SOPMETHANE31.48MOL %0.0002
SOPNITROGEN (N2)42.96MOL %0.01
SOPOXYGEN (O2)6.37MOL %0.01
SOPPENTANE0.276MOL %0.0001
SOPPROPANE5.69MOL %0.0001
SOPPROPENE0.0026MOL %0.0001
SOPSPECIFIC GRAVITY0.94RATIO_AIR

 Sample ID:   663441     Sample Date:  8/28/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 663441    ISOTECH ID: 936218
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.35mg/L0.01
SOPETHANE2.7mg/L0.0002
SOPMETHANE6mg/L0.0002
SOPNITROGEN (N2)13mg/L0.02
SOPPROPANE3mg/L0.0003

 Sample ID:   636551     Sample Date:  3/31/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 636551    ISOTECH ID: 823987
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.357MOL %0.005
SOPBRITISH THERMAL UNITS974BTU
SOPBUTANE1.38MOL %0.0001
SOPC6+ (hexanes +)0.298MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.7
SOPDELTA 13C C2-31.56
SOPDELTA 13C C3-27.45
SOPDELTA 13C iC4-29.6
SOPDelta 13C iC5-27.8
SOPDELTA 13C nC4-26.08
SOPDelta 13C nC5-25.7
SOPDELTA D C1-222.3
SOPETHANE11.79MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.79NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.628MOL %0.0001
SOPISOPENTANE0.301MOL %0.0001
SOPMETHANE52.8MOL %0.0002
SOPNITROGEN (N2)19.15MOL %0.01
SOPOXYGEN (O2)8.02MOL %0.01
SOPPENTANE0.201MOL %0.0001
SOPPROPANE5.08MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.833RATIO_AIR

 Sample ID:   636552     Sample Date:  3/31/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 636552    ISOTECH ID: 823987
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPETHANE6.3mg/L0.0002
SOPMETHANE14mg/L0.0002
SOPPROPANE3.8mg/L0.0003

 Sample ID:   636554     Sample Date:  3/31/2022     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 636554    Accutest ID: DA43441-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   636553     Sample Date:  3/31/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 636553    Accutest ID: DA43440-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8BARIUM0.101mg/L0.002
E200.8BORON0.552mg/L0.5
E200.8CALCIUM3.03mg/L0.25
E200.8IRON1.94mg/L0.05
E200.8MAGNESIUM0.482mg/L0.25
E200.8MANGANESE0.0383mg/L0.001
E200.8POTASSIUM1.37mg/L0.25
E200.8SELENIUMNDmg/L0.001U
E200.8SODIUM254mg/L13
E200.8STRONTIUM0.126mg/L0.05
E300.0BROMIDE3.9mg/L0.1
E300.0CHLORIDE373mg/L13
E300.0FLUORIDE5.7mg/L0.2
E300.0NITRATENDmg/L0.02U
E300.0NITRATE/NITRITE AS NNDmg/L0.12U
E300.0NITRITENDmg/L0.1U
E300.0SULFATENDmg/L1U
FIELDpH, FIELD10.4SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1500UMHOS/CM0.5
FIELDTEMPERATURE, FIELD22.3degrees C
SM1030CATION - ANION BALANCE6.5%
SM2320BBICARBONATE ALKALINITY as CACO346.3mg/L5
SM2320BCARBONATE ALKALINITY AS CACO352.5mg/L5
SM2320BTOTAL ALKALINITY AS CACO398.8mg/L5
SW8015TEPH DIESEL RANGE ORGANICS6.27mg/L0.19
SW8015TVPH - Gasoline Range Organics8.52mg/L0.2
SW8260BENZENE459ug/L25
SW8260ETHYLBENZENE102ug/L1
SW8260M-+P-XYLENE1060ug/L25
SW8260o-XYLENE281ug/L25
SW8260TOLUENE1910ug/L25
SW8260TOTAL XYLENES1340ug/L25

 Sample ID:   636555     Sample Date:  3/31/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 636555    ISOTECH ID: 824057
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1238BTU
SOPBUTANE1.71MOL %0.0001
SOPC6+ (hexanes +)0.0041MOL %0.0001
SOPCARBON DIOXIDE2.73MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46
SOPDELTA 13C C2-29.3
SOPDELTA 13C C3-26.3
SOPDELTA 13C CO23.54
SOPDELTA 13C iC4-29.86
SOPDelta 13C iC5-27.8
SOPDELTA 13C nC4-25.97
SOPDelta 13C nC5-25.08
SOPDELTA D C1-212.6
SOPETHANE11.74MOL %0.0001
SOPETHENE0.0002MOL %0.0001
SOPHelium0.0081MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.855MOL %0.0001
SOPISOPENTANE0.621MOL %0.0001
SOPMETHANE76.92MOL %0.0002
SOPNITROGEN (N2)0.25MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.492MOL %0.0001
SOPPROPANE4.67MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.742RATIO_AIR

 Sample ID:   624649     Sample Date:  3/9/2021     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 624649    ISOTECH ID: 787849
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1378BTU
SOPBUTANE2.59MOL %0.0001
SOPC6+ (hexanes +)0.0389MOL %0.0001
SOPCARBON DIOXIDE3.12MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.1
SOPDELTA 13C C2-29.5
SOPDELTA 13C C3-26.7
SOPDELTA 13C CO23.2
SOPDELTA 13C iC4-29.9
SOPDelta 13C iC5-28
SOPDELTA 13C nC4-26.3
SOPDelta 13C nC5-25.9
SOPDELTA D C1-226
SOPETHANE18.46MOL %0.0001
SOPETHENE0.0003MOL %0.0001
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE1.37MOL %0.0001
SOPISOPENTANE0.72MOL %0.0001
SOPMETHANE64.71MOL %0.0002
SOPNITROGEN (N2)0.21MOL %0.01
SOPOXYGEN (O2)0.049MOL %0.01
SOPPENTANE0.59MOL %0.0001
SOPPROPANE8.14MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.837RATIO_AIR

 Sample ID:   624646     Sample Date:  3/9/2021     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 624646    ISOTECH ID: 786269
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.358MOL %0.005
SOPARGON0.4mg/L0.02
SOPBRITISH THERMAL UNITS1014BTU
SOPBUTANE1.37MOL %0.0001
SOPC6+ (hexanes +)0.105MOL %0.0001
SOPCARBON DIOXIDE0.016MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.65
SOPDELTA 13C C2-31.6
SOPDELTA 13C C3-27.44
SOPDELTA 13C iC4-30.29
SOPDelta 13C iC5-28.5
SOPDELTA 13C nC4-26.01
SOPDelta 13C nC5-26.5
SOPDELTA D C1-240
SOPETHANE10mg/L0.0003
SOPETHANE11.76MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.65NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.726MOL %0.0001
SOPISOPENTANE0.361MOL %0.0001
SOPMETHANE25mg/L0.0003
SOPMETHANE56.62MOL %0.0002
SOPNITROGEN (N2)11mg/L0.02
SOPNITROGEN (N2)15.82MOL %0.01
SOPOXYGEN (O2)7.38MOL %0.01
SOPPENTANE0.211MOL %0.0001
SOPPROPANE6.6mg/L0.0004
SOPPROPANE5.27MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.815RATIO_AIR

 Sample ID:   624647     Sample Date:  3/9/2021     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 624647    Accutest ID: DA33028-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.529mg/L0.05
E200.7CALCIUM3.6mg/L0.4
E200.7IRON0.295mg/L0.01
E200.7MAGNESIUM0.453mg/L0.2
E200.7MANGANESE0.0151mg/L0.005
E200.7POTASSIUM1.77mg/L1
E200.7SODIUM333mg/L0.4
E200.7STRONTIUM0.156mg/L0.005
E200.8BARIUM0.0878mg/L0.004
E200.8SELENIUM0.0143mg/L0.0008
E300.0BROMIDE4.1mg/L0.1
E300.0CHLORIDE443mg/L25
E300.0FLUORIDE5.7mg/L0.2
E300.0NITRATE0.034mg/L0.02
E300.0Nitrite as NO2NDmg/L0.04U
E300.0SULFATENDmg/L1U
FIELDpH, FIELD10.2SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1880UMHOS/CM0.5
FIELDTEMPERATURE, FIELD16.5degrees C
SM1030CATION - ANION BALANCE0.03%
SM2320BBICARBONATE ALKALINITY as CACO375mg/L5
SM2320BCARBONATE ALKALINITY AS CACO320mg/L5
SM2320BTOTAL ALKALINITY AS CACO395mg/L5
SW8015TEPH DIESEL RANGE ORGANICS75.8mg/L2
SW8015TVPH - Gasoline Range Organics9.79mg/L0.5
SW8260BENZENE610ug/L10
SW8260ETHYLBENZENE81.6ug/L10
SW8260M-+P-XYLENE947ug/L10
SW8260o-XYLENE241ug/L10
SW8260TOLUENE1800ug/L50
SW8260TOTAL XYLENES1190ug/L10

 Sample ID:   624648     Sample Date:  3/9/2021     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 624648    Accutest ID: DA33027-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U