Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#250324 Information View DocsDoc View GISGIS
Sample Site ID250324
FacilityTypeOGProj Number
CountyWELD - 123LocationNWSE 11 3N67W
Elevation4769Lat/Long40.23801/-104.85643
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-18127Well Name:PSC 33-11
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWSE  11 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   606178     Sample Date:  03/12/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 606178    ISOTECH ID: 709277
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0146MOL %0.005
SOPBRITISH THERMAL UNITS1209BTU
SOPBUTANE1.54MOL %0.0001
SOPC6+ (hexanes +)0.333MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-50.44
SOPDELTA 13C C2-35.18
SOPDELTA 13C C3-30.6
SOPDELTA 13C iC4-32.16
SOPDelta 13C iC5-28.69
SOPDELTA 13C nC4-29.3
SOPDelta 13C nC5-28.4
SOPDELTA D C1-252.4
SOPETHANE8.37MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0355MOL %0.005
SOPHYDROGEN0.0133MOL %0.01
SOPISOBUTANE0.614MOL %0.0001
SOPISOPENTANE0.397MOL %0.0001
SOPMETHANE81.45MOL %0.0002
SOPNITROGEN (N2)2.06MOL %0.01
SOPOXYGEN (O2)0.23MOL %0.01
SOPPENTANE0.402MOL %0.0001
SOPPROPANE4.54MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.703RATIO_AIR

 Sample ID:   606179     Sample Date:  03/12/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 606179    ISOTECH ID: 709276
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1267BTU
SOPBUTANE1.7MOL %0.0001
SOPC6+ (hexanes +)0.0449MOL %0.0001
SOPCARBON DIOXIDE1.13MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.14
SOPDELTA 13C C2-31.33
SOPDELTA 13C C3-28.13
SOPDELTA 13C CO20.74
SOPDELTA 13C iC4-30.74
SOPDelta 13C iC5-28.05
SOPDELTA 13C nC4-27.13
SOPDelta 13C nC5-26.39
SOPDELTA D C1-240.3
SOPETHANE12.68MOL %0.0001
SOPETHENE0.0001MOL %0.0001
SOPHelium0.0076MOL %0.005
SOPHYDROGEN0.471MOL %0.01
SOPISOBUTANE0.883MOL %0.0001
SOPISOPENTANE0.285MOL %0.0001
SOPMETHANE75.82MOL %0.0002
SOPNITROGEN (N2)0.32MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.225MOL %0.0001
SOPPROPANE6.43MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.736RATIO_AIR

 Sample ID:   606181     Sample Date:  03/12/2019     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 606181    Weatherford Laboratories  ID: 6126090423
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane1960ppm
G02G1,1-dimethylcyclopentane1834ppm
G02G1,2,3-trimethylcyclopentane1348ppm
G02G1,2,4-trimethylcyclopentane1739ppm
G02G2,2,3-trimethylbutane96ppm
G02G2,2-DIMETHYLBUTANE216ppm
G02G2,2-dimethylpentane470ppm
G02G2,3-DIMETHYLBUTANE1256ppm
G02G2,3-dimethylpentane230ppm
G02G2,3-dimethylpentane1939ppm
G02G2,4-dimethylpentane1286ppm
G02G2-METHYLPENTANE9296ppm
G02G3-ethylpentane375ppm
G02G3-methylhexane6612ppm
G02G3-methylhexane6702ppm
G02G3-METHYLPENTANE5791ppm
G02GBENZENE2277ppm
G02GBUTANE4518ppm
G02Gcis-1,3-dimethylcyclopentane2608ppm
G02GCYCLOHEXANE13869ppm
G02GCYCLOPENTANE1826ppm
G02GDecane13215ppm
G02GETHYLBENZENE1777ppm
G02Gethylcyclopentane828ppm
G02GHEPTANES, MIXED ISOMERS19170ppm
G02GHEXANES18258ppm
G02Ghighly branched C25 isoprenoid274ppm
G02GISOBUTANE829ppm
G02GISOPENTANE7680ppm
G02Gisoprenoid C102606ppm
G02Gisoprenoid C112598ppm
G02Gisoprenoid C132406ppm
G02Gisoprenoid C141876ppm
G02Gisoprenoid C152498ppm
G02Gisoprenoid C163178ppm
G02Gisoprenoid C182556ppm
G02Gisoprenoid C92135ppm
G02Gm-XYLENE8194ppm
G02GMETHYL CYCLOHEXANE28918ppm
G02GMETHYLCYCLOPENTANE10420ppm
G02Gn-C1112262ppm
G02Gn-C1210238ppm
G02Gn-C139726ppm
G02Gn-C148819ppm
G02Gn-C158545ppm
G02Gn-C167115ppm
G02Gn-C176397ppm
G02Gn-C185526ppm
G02Gn-C195125ppm
G02Gn-C204872ppm
G02Gn-C214294ppm
G02Gn-C224067ppm
G02Gn-C233716ppm
G02Gn-C243502ppm
G02Gn-C253111ppm
G02Gn-C262817ppm
G02Gn-C272286ppm
G02Gn-C281768ppm
G02Gn-C291465ppm
G02Gn-C30948ppm
G02Gn-C31686ppm
G02Gn-c32420ppm
G02Gn-C33420ppm
G02Gn-C34310ppm
G02Gn-C35198ppm
G02Gn-C3689ppm
G02Gn-C3784ppm
G02Gn-C3827ppm
G02Gn-C390ppm
G02Gn-C400ppm
G02Gn-C410ppm
G02Gn-octane18912ppm
G02GNormal Alkane C915302ppm
G02Go-XYLENE3889ppm
G02Gp-XYLENE2536ppm
G02GPENTANE13054ppm
G02GPHENANTHRENE280ppm
G02Gphytane1867ppm
G02Gpristane3710ppm
G02GPropyl-benzene1469ppm
G02GTOLUENE10164ppm
G02Gtrans-1,2-dimethylcyclopentane3698ppm
G02Gtrans-1,3-dimethylcyclopentane2424ppm