Sample ID: 535265 Sample Date: 09/17/2013 Matrix: WATER Collection Point: Dom Type: Dom Lab: ALS Lab Group (formerly Paragon)| Sample Results for Sample # 535265 ALS Lab Group (formerly Paragon) ID: 1309235-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U | | SW8260 | TVPH - Gasoline Range Organics | 51 | ug/L | 100 | |
Sample ID: 535267 Sample Date: 09/17/2013 Matrix: WATER Collection Point: Dom Type: Dom Lab: ALS Lab Group (formerly Paragon)| Sample Results for Sample # 535267 ALS Lab Group (formerly Paragon) ID: 1309234-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | BART | BACTERIA, IRON RELATED | 1 | NU | 1 | PRSNT | | BART | BACTERIA, SLIME FORMING | 1 | NU | 1 | PRSNT | | BART | BACTERIA, SULFATE REDUCING | 1 | NU | 1 | PRSNT | | E200.8 | BARIUM | 110 | ug/L | 1 | | | E200.8 | BORON | 180 | ug/L | 50 | | | E200.8 | CALCIUM | 4700 | ug/L | 1000 | | | E200.8 | IRON | 290 | ug/L | 100 | | | E200.8 | MAGNESIUM | 1100 | ug/L | 100 | | | E200.8 | MANGANESE | 15 | ug/L | 2 | | | E200.8 | POTASSIUM | 2000 | ug/L | 1000 | | | E200.8 | SELENIUM | ND | ug/L | 1 | U | | E200.8 | SODIUM | 330000 | ug/L | 1000 | | | E200.8 | STRONTIUM | 130 | ug/L | 1 | | | E300.0 | BROMIDE | 0.69 | mg/L | 0.2 | | | E300.0 | CHLORIDE | 86 | mg/L | 2 | | | E300.0 | FLUORIDE | 2.4 | mg/L | 0.1 | | | E300.0 | NITRATE AS N | ND | mg/L | 0.2 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.1 | U | | E300.0 | NITRITE AS N | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | ND | mg/L | 1 | U | | E365.2 | PHOSPHORUS | 0.2 | mg/L | 0.05 | | | RSK175 | ETHANE | 26 | ug/L | 2 | | | RSK175 | METHANE | 9100 | ug/L | 1 | | | RSK175 | PROPANE | ND | ug/L | 1 | U | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 600 | mg/L | 20 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 610 | mg/L | 20 | | | SM2510B | SPECIFIC CONDUCTIVITY | 1359 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 840 | mg/L | 40 | | | SM4500-H+ B | PH, LAB | 8.42 | SU | 0.1 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.5 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | 5.9 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U | | SW8260 | TVPH - Gasoline Range Organics | 35 | ug/L | 100 | |
Sample ID: 543724 Sample Date: 04/20/2015 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECH| Sample Results for Sample # 543724 ISOTECH ID: 506702 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.378 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 796 | BTU | | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | | SOP | CARBON DIOXIDE | 0.71 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -70.83 | ‰ | | | | SOP | DELTA 13C C2 | -46.9 | ‰ | | | | SOP | DELTA D C1 | -277.4 | ‰ | | | | SOP | ETHANE | 0.0884 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | HELIUM DILUTION FACTOR | 0.51 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | | SOP | METHANE | 78.36 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 19.56 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.9 | MOL % | 0.01 | | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | | SOP | PROPANE | ND | MOL % | 0.0001 | ND | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.65 | RATIO_AIR | | |
Sample ID: 543721 Sample Date: 04/20/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: Accutest| Sample Results for Sample # 543721 Accutest ID: D69944-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | | BART | BACTERIA, SULFATE REDUCING | 200 | cfu/ml | 200 | | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1400 | UMHOS/CM | 0.5 | | | E150.1 | PH, LAB | 8.4 | SU | | | | E170.1 | TEMPERATURE, FIELD | 17.46 | degrees C | | | | E200.7 | BORON | 0.234 | mg/L | 0.05 | | | E200.7 | CALCIUM | 4.72 | mg/L | 0.4 | | | E200.7 | IRON | 0.01 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | 1.17 | mg/L | 0.2 | | | E200.7 | MANGANESE | 0.0086 | mg/L | 0.005 | | | E200.7 | POTASSIUM | 2.06 | mg/L | 1 | | | E200.7 | SODIUM | 319 | mg/L | 0.4 | | | E200.7 | STRONTIUM | 0.126 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0941 | mg/L | 0.004 | | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | | E300.0 | BROMIDE | 0.83 | mg/L | 0.1 | | | E300.0 | CHLORIDE | 97 | mg/L | 2.5 | | | E300.0 | FLUORIDE | 2.5 | mg/L | 0.2 | | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | | E300.0 | SULFATE | ND | mg/L | 1 | U | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.05 | mg/L | | | | FIELD | OXIDATION REDUCTION POTENTIAL | -210 | mV | | | | FIELD | TURBIDITY | 4 | NTU | | | | HACH | PHOSPHORUS | 0.054 | mg/L | 0.01 | | | RSK175 | ETHANE | 0.0397 | mg/L | 0.0016 | | | RSK175 | METHANE | 12.2 | mg/L | 0.04 | | | RSK175 | PROPANE | ND | mg/L | 0.0022 | U | | SM1030 | CATION - ANION BALANCE | 0.73 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 580 | mg/L | 5 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 7.2 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 587 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 1160 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 826 | mg/L | 10 | | | SM4500-H+ B | PH, LAB | 8.35 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 0.5 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 543719 Sample Date: 04/20/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: Accutest| Sample Results for Sample # 543719 Accutest ID: D69945-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 0.5 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 543725 Sample Date: 04/20/2015 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECH| Sample Results for Sample # 543725 ISOTECH ID: 506702 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.41 | mg/L | 0.01 | | | SOP | ETHANE | 0.078 | mg/L | 0.0002 | | | SOP | METHANE | 34 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 13 | mg/L | 0.01 | | | SOP | PROPANE | ND | mg/L | 0.0002 | ND |
|
|