Sample ID: 541999 Sample Date: 01/15/2015 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 541999 ISOTECH ID: 485504 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.763 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 558 | BTU | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | SOP | CARBON DIOXIDE | 0.3 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -72.85 | ‰ | | | SOP | DELTA D C1 | -259.8 | ‰ | | | SOP | ETHANE | 0.0579 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.68 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | SOP | METHANE | 54.95 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 43.27 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.66 | MOL % | 0.01 | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | SOP | PROPANE | ND | MOL % | 0.0001 | ND | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.746 | RATIO_AIR | | |
Sample ID: 542025 Sample Date: 01/15/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 542025 Accutest ID: D66728-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 542000 Sample Date: 01/15/2015 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 542000 ISOTECH ID: 485504 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ETHANE | 0.038 | mg/L | 0.0002 | | SOP | METHANE | 18 | mg/L | 0.0002 | | SOP | PROPANE | ND | mg/L | 0.0003 | ND |
Sample ID: 542002 Sample Date: 01/15/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 542002 Accutest ID: D66724-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 6500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 973 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.9 | SU | | | E170.1 | TEMPERATURE, FIELD | 11.51 | degrees C | | | E200.7 | BORON | 0.397 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.58 | mg/L | 0.4 | | E200.7 | IRON | 0.0894 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.394 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0057 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.31 | mg/L | 1 | | E200.7 | SODIUM | 244 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0504 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0382 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.52 | mg/L | 0.1 | | E300.0 | CHLORIDE | 50.2 | mg/L | 1 | | E300.0 | FLUORIDE | 2.2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 1.7 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.01 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | TURBIDITY | 0.59 | NTU | | | HACH | PHOSPHORUS | 0.047 | mg/L | 0.01 | | RSK175 | ETHANE | 0.02 | mg/L | 0.0016 | | RSK175 | METHANE | 7.7 | mg/L | 0.016 | | RSK175 | PROPANE | ND | mg/L | 0.0022 | U | SM1030 | CATION - ANION BALANCE | 2.8 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 412 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 23.9 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 436 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 831 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 580 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.72 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|