Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#753527 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID753527
FacilityTypeDOMProj Number
CountyWELD - 123LocationNWSW 3 1N66W
Elevation5039Lat/Long40.079822/-104.769939
DWR Receipt #9064848 WellDepth783
 
Related Facility/Well
API Number: 05- - Well Name:No Facility 1
Well Status:CLOperator Name:UNKNOWN
Location:      

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   547929     Sample Date:  12/10/2015     Matrix:  GAS     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 547929    ISOTECH ID: 546512
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.799MOL %0.005
SOPBRITISH THERMAL UNITS522BTU
SOPBUTANENDMOL %0.0001ND
SOPC6+ (hexanes +)NDMOL %0.0001ND
SOPCARBON DIOXIDE0.22MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-72.06
SOPDELTA 13C C2-45.9
SOPDELTA D C1-264.9
SOPETHANE0.0576MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.64NA
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANENDMOL %0.0001ND
SOPISOPENTANENDMOL %0.0001ND
SOPMETHANE51.48MOL %0.0002
SOPNITROGEN (N2)45.93MOL %0.01
SOPOXYGEN (O2)1.51MOL %0.01
SOPPENTANENDMOL %0.0001ND
SOPPROPANENDMOL %0.0001ND
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.761RATIO_AIR

 Sample ID:   547932     Sample Date:  12/10/2015     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 547932    Accutest ID: D78138-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L0.5U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   547926     Sample Date:  12/10/2015     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 547926    Accutest ID: D78139-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATEDNDcfu/ml25U
BARTBACTERIA, SLIME FORMINGNDcfu/ml500U
BARTBACTERIA, SULFATE REDUCINGNDcfu/ml200U
E120.1SPECIFIC CONDUCTIVITY, FIELD833UMHOS/CM0.5
E150.1PH, LAB8.8SU
E170.1TEMPERATURE, FIELD18.54degrees C
E200.7BORON0.244mg/L0.05
E200.7CALCIUM1.6mg/L0.4
E200.7IRON0.0534mg/L0.01
E200.7MAGNESIUM1.03mg/L0.2
E200.7MANGANESE0.0101mg/L0.005
E200.7POTASSIUM1.15mg/L1
E200.7SODIUM203mg/L0.4
E200.7STRONTIUM0.0421mg/L0.005
E200.8BARIUM0.0421mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDENDmg/L0.5U
E300.0CHLORIDE40.3mg/L5
E300.0FLUORIDE1.6mg/L1
E300.0NITRATENDmg/L0.1U
E300.0NITRATE/NITRITE AS NNDmg/L0.14U
E300.0Nitrite as NO20.067mg/L0.04
E300.0SULFATE4.2mg/L0.5
E360.1DISSOLVED OXYGEN, FIELD0.08mg/L
FIELDOXIDATION REDUCTION POTENTIAL-130mV
FIELDTURBIDITY1.1NTU
HACHPHOSPHORUS0.069mg/L0.01
RSK175ETHANE0.0247mg/L0.0016
RSK175METHANE8.03mg/L0.016
RSK175PROPANENDmg/L0.0022U
SM1030CATION - ANION BALANCE1.5%
SM2320BBICARBONATE ALKALINITY as CACO3341mg/L5
SM2320BCARBONATE ALKALINITY AS CACO336.1mg/L5
SM2320BTOTAL ALKALINITY AS CACO3377mg/L5
SM2510BSPECIFIC CONDUCTIVITY846UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS507mg/L10
SM4500-H+ BPH, LAB8.81SU
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.19U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L0.5U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   547930     Sample Date:  12/10/2015     Matrix:  WATER     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 547930    ISOTECH ID: 546512
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.66mg/L0.01
SOPETHANE0.039mg/L0.0002
SOPMETHANE17mg/L0.0002
SOPNITROGEN (N2)23mg/L0.01
SOPPROPANENDmg/L0.0003ND

 Sample ID:   539218     Sample Date:  07/31/2014     Matrix:  GAS     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 539218    ISOTECH ID: 451219
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.917MOL %0.005
SOPBRITISH THERMAL UNITS458BTU
SOPBUTANENDMOL %0.0001ND
SOPC6+ (hexanes +)NDMOL %0.0001ND
SOPCARBON DIOXIDE0.15MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-73.42
SOPDELTA 13C C2-46.3
SOPDELTA D C1-271.1
SOPETHANE0.0501MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.52NA
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANENDMOL %0.0001ND
SOPISOPENTANENDMOL %0.0001ND
SOPMETHANE45.08MOL %0.0002
SOPNITROGEN (N2)50.17MOL %0.01
SOPOXYGEN (O2)3.63MOL %0.01
SOPPENTANENDMOL %0.0001ND
SOPPROPANENDMOL %0.0001ND
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.791RATIO_AIR

 Sample ID:   539213     Sample Date:  07/31/2014     Matrix:  WATER     Collection Point:  Dom     Type:  Dom     Lab:  ALS Lab Group (formerly Paragon)

Sample Results for Sample # 539213    ALS Lab Group (formerly Paragon) ID: 1408006-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   539219     Sample Date:  07/31/2014     Matrix:  WATER     Collection Point:       Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 539219    ISOTECH ID: 451219
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPETHANE0.039mg/L0.0002
SOPMETHANE17mg/L0.0002
SOPPROPANENDmg/L0.0002ND

 Sample ID:   539215     Sample Date:  07/31/2014     Matrix:  WATER     Collection Point:  Dom     Type:  Dom     Lab:  ALS Lab Group (formerly Paragon)

Sample Results for Sample # 539215    ALS Lab Group (formerly Paragon) ID: 1408004-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATEDNDcfu/ml1U
BARTBACTERIA, SLIME FORMINGNDcfu/ml1U
BARTBACTERIA, SULFATE REDUCINGNDcfu/ml1U
E200.8BARIUM37ug/L1
E200.8BORON280ug/L50
E200.8CALCIUMNDug/L1000U
E200.8IRONNDug/L100U
E200.8MAGNESIUM290ug/L100
E200.8MANGANESE6.7ug/L2
E200.8POTASSIUMNDug/L1000U
E200.8SELENIUMNDug/L1U
E200.8SODIUM210000ug/L1000
E200.8STRONTIUM38ug/L1
E300.0BROMIDE0.35mg/L0.2
E300.0CHLORIDE36mg/L2
E300.0FLUORIDE1.6mg/L0.1
E300.0NITRATE AS NNDmg/L0.2U
E300.0NITRATE/NITRITE AS NNDmg/L0.1U
E300.0NITRITE AS NNDmg/L0.1U
E300.0SULFATENDmg/L1U
E365.2PHOSPHORUS0.09mg/L0.05
FIELDDISSOLVED OXYGEN, FIELD0.05mg/L
FIELDOXIDATION REDUCTION POTENTIAL, FIELD-285.4mV
FIELDpH, FIELD8.21SU
FIELDSPECIFIC CONDUCTIVITY, FIELD875UMHOS/CM
FIELDTEMPERATURE, FIELD18.52degrees C
FIELDTURBIDITY, FIELD0.41NTU
RSK175ETHANE24ug/L2
RSK175METHANE7400ug/L1
RSK175PROPANENDug/L1U
SM2320BBICARBONATE ALKALINITY as CACO3380mg/L20
SM2320BCARBONATE ALKALINITY AS CACO327mg/L20
SM2320BTOTAL ALKALINITY AS CACO3410mg/L20
SM2510BSPECIFIC CONDUCTIVITY849UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS510mg/L20
SM4500-H+ BPH, LAB8.8SU0.1
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.5U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U