Sample Site ID752932
FacilityTypeGWProj Number
CountyWELD - 123LocationSWNW 15 1N68W
ElevationLat/Long40.052095054/-104.99742567
DWR Receipt #9066262WellDepth600
 
Related Facility/Well
API Number: 05- - Well Name:No Facility 1
Well Status:CLOperator Name:UNKNOWN
Location:      

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   627158     Sample Date:  6/21/2021     Matrix:  WATER     Collection Point:  Dom     Type:  TB     Lab:  Accutest

Sample Results for Sample # 627158    Accutest ID: DA35339-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   627160     Sample Date:  6/21/2021     Matrix:  WATER     Collection Point:  Dom     Type:  GW     Lab:  Accutest

Sample Results for Sample # 627160    Accutest ID: DA35338-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATED9000cfu/ml25
BARTBACTERIA, SLIME FORMING13000cfu/ml500
BARTBACTERIA, SULFATE REDUCING 27000cfu/ml200
E200.7BORON0.524mg/L0.05
E200.7CALCIUM19.2mg/L0.4
E200.7IRON0.0537mg/L0.01
E200.7MAGNESIUM8.03mg/L0.2
E200.7MANGANESE0.0279mg/L0.005
E200.7POTASSIUM5.94mg/L1
E200.7SODIUM1090mg/L2
E200.7STRONTIUM1.01mg/L0.005
E200.8BARIUM0.0096mg/L0.002
E200.8SELENIUMNDmg/L0.0004U
E300.0BROMIDE0.5mg/L0.5
E300.0CHLORIDE79mg/L5
E300.0FLUORIDENDmg/L1U
E300.0NITRATENDmg/L0.1U
E300.0NITRATE/NITRITE AS NNDmg/L0.14U
E300.0Nitrite as NO2NDmg/L0.04U
E300.0SULFATE1700mg/L50
E365.1PHOSPHORUS0.81mg/L0.01
FIELDDISSOLVED OXYGEN, FIELD0.02mg/L
FIELDOXIDATION REDUCTION POTENTIAL72.9mV
FIELDpH, FIELD8.1SU
FIELDSPECIFIC CONDUCTIVITY, FIELD4950UMHOS/CM0.5
FIELDTEMPERATURE, FIELD18.99degrees C
FIELDTURBIDITY3.1NTU
RSK175ETHANENDmg/L0.0016U
RSK175METHANE0.0049mg/L0.0008
RSK175PROPANENDmg/L0.0022U
SM1030CATION - ANION BALANCE0.81%
SM2320BBICARBONATE ALKALINITY as CACO3535mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L5U
SM2320BTOTAL ALKALINITY AS CACO3535mg/L5
SM2510BSPECIFIC CONDUCTIVITY4070UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS2920mg/L10
SM4500-H+ BpH, FIELD8.48SU
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.19U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   604957     Sample Date:  1/14/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 604957    Accutest ID: DA12830-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   604958     Sample Date:  1/14/2019     Matrix:  WATER     Collection Point:  Dom     Type:  DOM     Lab:  Accutest

Sample Results for Sample # 604958    Accutest ID: DA12829-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATED2200cfu/ml25
BARTBACTERIA, SLIME FORMING13000cfu/ml500
BARTBACTERIA, SULFATE REDUCING 6000cfu/ml200
E200.7BORON0.539mg/L0.05
E200.7CALCIUM18.2mg/L0.4
E200.7IRONNDmg/L0.01U
E200.7MAGNESIUM7.37mg/L0.2
E200.7MANGANESE0.0189mg/L0.005
E200.7POTASSIUM5.2mg/L1
E200.7SODIUM1050mg/L4
E200.7STRONTIUM0.983mg/L0.005
E200.8BARIUM0.0055mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE0.5mg/L0.05
E300.0CHLORIDE98.8mg/L50
E300.0FLUORIDE0.85mg/L0.1
E300.0NITRATENDmg/L1U
E300.0NITRATE/NITRITE AS NNDmg/L1.4U
E300.0Nitrite as NO2NDmg/L0.4U
E300.0SULFATE1790mg/L50
E365.1PHOSPHORUS0.025mg/L0.01
FIELDDISSOLVED OXYGEN, FIELD0.16mg/L
FIELDOXIDATION REDUCTION POTENTIAL-173.4mV
FIELDpH, FIELD8.2SU
FIELDSPECIFIC CONDUCTIVITY, FIELD4590UMHOS/CM0.5
FIELDTEMPERATURE, FIELD16.5degrees C
FIELDTURBIDITY1.54NTU
RSK175ETHANENDmg/L0.0016U
RSK175METHANE0.0068mg/L0.0008
RSK175PROPANENDmg/L0.0022U
SM1030CATION - ANION BALANCE3.6%
SM2320BBICARBONATE ALKALINITY as CACO3539mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L5U
SM2320BTOTAL ALKALINITY AS CACO3540mg/L5
SM2510BSPECIFIC CONDUCTIVITY4500UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS3240mg/L10
SM4500-H+ BpH, FIELD8.29SU
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.19U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   535131     Sample Date:  10/14/2013     Matrix:  WATER     Collection Point:  Dom     Type:  DOM     Lab:  ALS Houston

Sample Results for Sample # 535131    ALS Houston ID: 1310683-01A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E300.0CHLORIDE84.1mg/L
E300.0FLUORIDE1.11mg/L
E300.0NITRATENDmg/LU
E300.0NITRATE/NITRITE AS NNDmg/LU
E300.0Nitrite as NO2NDmg/LU
E300.0SULFATE1980mg/L
RSK175METHANE0.0136mg/L
SM2320BBICARBONATE ALKALINITY as CACO3586mg/L
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/LU
SM2320BTOTAL ALKALINITY AS CACO3590mg/L
SM2510BSPECIFIC CONDUCTIVITY4760UMHOS/CM
SM2540CTOTAL DISSOLVED SOLIDS3220mg/L
SM4500-H+ BPH, LAB8.3pH UnitsH
SW6020CALCIUM17.8mg/L
SW6020IRONNDmg/LU
SW6020MAGNESIUM7.89mg/L
SW6020MANGANESE0.0252mg/L
SW6020POTASSIUM4.94mg/L
SW6020SELENIUMNDmg/LU
SW6020SODIUM1200mg/L

 Sample ID:   535132     Sample Date:  10/14/2013     Matrix:  WATER     Collection Point:  Dom     Type:  DOM     Lab:  ALS Houston

Sample Results for Sample # 535132    ALS Houston ID: 1310683-02A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
RSK175METHANENDmg/LU