Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#211386 Information View DocsDoc View GISGIS
Sample Site ID211386
FacilityTypeOGProj Number
CountyGARFIELD - 045LocationNWSE 4 7S92W
Elevation5975Lat/Long39.47384/-107.6692
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-045-07146Well Name:OKAGAWA 4-10 (J4E)
Well Status:PROperator Name:QB ENERGY OPERATING LLC
Location:NWSE  4  7S  92W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   531734     Sample Date:  12/03/2010     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531734    Questar Applied Technology Services
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0043MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.006MOL %
SOP2,3-DIMETHYLBUTANE0.0136MOL %
SOP2-METHYLPENTANE0.0411MOL %
SOP26# Gasoline GPM0.410128gal/MCF
SOP3-METHYLPENTANE0.0196MOL %
SOPAvg Molecular Weight19.457gm/mole
SOPBase Mol Percent101.197%v/v
SOPBENZENE0.0054MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1172BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1191.5BTU
SOPBUTANE0.6438MOL %
SOPButane GPM0.401454gal/MCF
SOPCARBON DIOXIDE0.2443MOL %
SOPCYCLOHEXANE0.0105MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0002MOL %
SOPETHANE10.4444MOL %
SOPETHYLBENZENE0.0001MOL %
SOPGas Compressibility0.9969NA
SOPGasoline GPM0.207518gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0433MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.6097MOL %
SOPISOPENTANE0.2147MOL %
SOPM-+P-XYLENE0.0005MOL %
SOPMETHANE83.7989MOL %
SOPMETHYL CYCLOHEXANE0.0061MOL %
SOPN-HEXANE0.0425MOL %
SOPNITROGEN (N2)0.1482MOL %
SOPNONANE0.0011MOL %
SOPo-XYLENE0.0001MOL %
SOPOCTANE, MIXED ISOMERS0.0019MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.1705MOL %
SOPPROPANE3.5519MOL %
SOPPropane GPM0.973443gal/MCF
SOPSample Pressure125PSIG
SOPSample Temperaturedegrees F
SOPSPECIFIC GRAVITY0.6734RATIO_AIR
SOPTOLUENE0.0023MOL %
SOPTotal non gas liquids GPM1.58258gal/MCF

 Sample ID:   531738     Sample Date:  12/03/2010     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531738    Questar Applied Technology Services ID: NA
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0003MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0002MOL %
SOP2,3-DIMETHYLBUTANE0.0009MOL %
SOP2-METHYLPENTANE0.0036MOL %
SOP26# Gasoline GPM0.029763gal/MCF
SOP3-METHYLPENTANE0.0022MOL %
SOPAvg Molecular Weight16.202gm/mole
SOPBase Mol Percent99.384%v/v
SOPBENZENE0.0007MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS998.1BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1014.7BTU
SOPBUTANE0.0065MOL %
SOPButane GPM0.003904gal/MCF
SOPCARBON DIOXIDE0.0099MOL %
SOPCYCLOHEXANE0.0038MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0016MOL %
SOPETHANE0.1387MOL %
SOPETHYLBENZENE0.0003MOL %
SOPGas Compressibility0.998NA
SOPGasoline GPM0.02629gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0352MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.0057MOL %
SOPISOPENTANE0.0056MOL %
SOPM-+P-XYLENE0.003MOL %
SOPMETHANE99.259MOL %
SOPMETHYL CYCLOHEXANE0.0105MOL %
SOPN-HEXANE0.0066MOL %
SOPNITROGEN (N2)0.4784MOL %
SOPNONANE0.0097MOL %
SOPo-XYLENE0.0004MOL %
SOPOCTANE, MIXED ISOMERS0.0139MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.0048MOL %
SOPPROPANE0.0172MOL %
SOPPropane GPM0.004714gal/MCF
SOPSample Pressure125PSIG
SOPSample Temperaturedegrees F
SOPSPECIFIC GRAVITY0.5606RATIO_AIR
SOPTOLUENE0.0042MOL %
SOPTotal non gas liquids GPM0.036337gal/MCF

 Sample ID:   531740     Sample Date:  01/21/2011     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  --

Sample Results for Sample # 531740    -- ID: 200908
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0074MOL %
SOPBRITISH THERMAL UNITS1011BTU
SOPBUTANE0.006MOL %
SOPC6+ (hexanes +)0.0285MOL %
SOPCARBON DIOXIDE0.006MOL %
SOPCARBON MONOXIDENDMOL %ND
SOPDELTA 13C C1-44per mil VPDB
SOPDELTA 13C C2-27.02per mil VPDB
SOPDELTA 13C C3per mil VPDB
SOPDELTA D C1-235.2per mil VSMOW
SOPETHANE0.129MOL %
SOPETHENENDMOL %ND
SOPHelium0.0215MOL %
SOPHYDROGEN0.0107MOL %
SOPISOBUTANE0.0055MOL %
SOPISOPENTANE0.0051MOL %
SOPMETHANE99.21MOL %
SOPNITROGEN (N2)0.5MOL %
SOPOXYGEN (O2)0.046MOL %
SOPPENTANE0.0041MOL %
SOPPROPANE0.0172MOL %
SOPSPECIFIC GRAVITY0.558RATIO_AIR

 Sample ID:   531736     Sample Date:  01/21/2011     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  --

Sample Results for Sample # 531736    -- ID: Okagawa 4-10
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0076MOL %
SOPBRITISH THERMAL UNITS1175BTU
SOPBUTANE0.592MOL %
SOPC6+ (hexanes +)0.106MOL %
SOPCARBON DIOXIDE0.22MOL %
SOPCARBON MONOXIDENDMOL %ND
SOPDELTA 13C C1-41.1per mil VPDB
SOPDELTA 13C C2-28.57per mil VPDB
SOPDELTA 13C C3-26.08per mil VPDB
SOPDELTA D C1-205.2per mil VSMOW
SOPETHANE10.36MOL %
SOPETHENENDMOL %ND
SOPHelium0.0041MOL %
SOPHYDROGENNDMOL %ND
SOPISOBUTANE0.589MOL %
SOPISOPENTANE0.187MOL %
SOPMETHANE83.72MOL %
SOPNITROGEN (N2)0.56MOL %
SOPOXYGEN (O2)0.21MOL %
SOPPENTANE0.139MOL %
SOPPROPANE3.31MOL %
SOPSPECIFIC GRAVITY0.668RATIO_AIR