Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#89067 Information View DocsDoc View GISGIS
Sample Site ID89067
FacilityTypeOGProj Number
CountyGARFIELD - 045LocationNENW 17 7S92 W
ElevationLat/Long39.45174/-107.69099
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-045-07397Well Name:COUEY 17-2
Well Status:PROperator Name:QB ENERGY OPERATING LLC
Location:NENW  17 7S  92W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   451195     Sample Date:  07/28/2009     Matrix:  GAS     Collection Point:       Type:  PRD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 451195    Questar Applied Technology Services
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
UnSpec2,2-DIMETHYLBUTANENDMOL %U
UnSpec2,2-DIMETHYLPROPANE (neopentane)0.0004Mol %
UnSpec2,3-DIMETHYLBUTANENDMOL %U
UnSpec2-METHYLPENTANE0.0001MOL %
UnSpec3-METHYLPENTANENDMOL %U
UnSpecBUTANE0.0267MOL %
UnSpecCARBON DIOXIDE0.003MOL %
UnSpecDECANES +0.0002MOL %
UnSpecETHANE5.5715MOL %
UnSpecHEPTANES, MIXED ISOMERS0.0005MOL %
UnSpecHYDROGEN SULFIDENDMOL %U
UnSpecISOBUTANE0.1237MOL %
UnSpecISOPENTANE0.0006MOL %
UnSpecMETHANE92.9039MOL %
UnSpecN-HEXANE0.0002MOL %
UnSpecNITROGEN (N2)0.422MOL %
UnSpecNONANENDMOL %U
UnSpecOCTANE, MIXED ISOMERSNDMOL %U
UnSpecOXYGEN (O2)NDMOL %U
UnSpecPENTANE0.0003MOL %
UnSpecPROPANE0.9469MOL %

 Sample ID:   531282     Sample Date:  07/28/2009     Matrix:  GAS     Collection Point:  BDH     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531282    Questar Applied Technology Services ID: 300107529
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0004MOL %
SOP2,3-DIMETHYLBUTANE0MOL %
SOP2-METHYLPENTANE0.0001MOL %
SOP26# Gasoline GPM0.009189gal/MCF
SOP3-METHYLPENTANE0MOL %
SOPAvg Molecular Weight17.206gm/mole
SOPBase Mol Percent98.739%v/v
SOPBENZENE0.5954MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1053.3BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1070.7BTU
SOPBUTANE0.0267MOL %
SOPButane GPM0.048774gal/MCF
SOPCARBON DIOXIDE0.003MOL %
SOPCYCLOHEXANE0MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0002MOL %
SOPETHANE5.5715MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9977NA
SOPGasoline GPM0.00079gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0005MOL %
SOPHYDROGEN SULFIDENDMOL %ND
SOPISOBUTANE0.1237MOL %
SOPISOPENTANE0.0006MOL %
SOPM-+P-XYLENE0MOL %
SOPMETHANE92.9039MOL %
SOPMETHYL CYCLOHEXANE0.0001MOL %
SOPN-HEXANE0.0002MOL %
SOPNITROGEN (N2)0.422MOL %
SOPNONANE0MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0MOL %
SOPOXYGEN (O2)NDMOL %ND
SOPPENTANE0.0003MOL %
SOPPROPANE0.9469MOL %
SOPPropane GPM0.26033gal/MCF
SOPSample Pressure265PSIG
SOPSample Temperature98degrees F
SOPSPECIFIC GRAVITY0.5954RATIO_AIR
SOPTOLUENE17.206MOL %
SOPTotal non gas liquids GPM0.309894gal/MCF

 Sample ID:   451194     Sample Date:  07/15/2009     Matrix:  GAS     Collection Point:       Type:  BDH     Lab:  Questar Applied Technology Services

Sample Results for Sample # 451194    Questar Applied Technology Services
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
UnSpec2,2-DIMETHYLBUTANE0.0037MOL %
UnSpec2,2-DIMETHYLPROPANE (neopentane)0.0035Mol %
UnSpec2,3-DIMETHYLBUTANE0.0101MOL %
UnSpec2-METHYLPENTANE0.0337MOL %
UnSpec3-METHYLPENTANE0.0175MOL %
UnSpecBUTANE0.3992MOL %
UnSpecCARBON DIOXIDE0.0079MOL %
UnSpecDECANES +0.0002MOL %
UnSpecETHANE5.4086MOL %
UnSpecHEPTANES, MIXED ISOMERS0.0803MOL %
UnSpecHYDROGEN SULFIDE0.0002MOL %
UnSpecISOBUTANE0.3929MOL %
UnSpecISOPENTANE0.1507MOL %
UnSpecMETHANE87.2872MOL %
UnSpecN-HEXANE0.0407MOL %
UnSpecNITROGEN (N2)4.1781MOL %
UnSpecNONANE0.003MOL %
UnSpecOCTANE, MIXED ISOMERS0.0121MOL %
UnSpecOXYGEN (O2)NDMOL %U
UnSpecPENTANE0.111MOL %
UnSpecPROPANE1.8594MOL %

 Sample ID:   531284     Sample Date:  07/09/2009     Matrix:  GAS     Collection Point:  BDH     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531284    Questar Applied Technology Services ID: 300107529
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0037MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0035MOL %
SOP2,3-DIMETHYLBUTANE0.0101MOL %
SOP2-METHYLPENTANE0.0337MOL %
SOP26# Gasoline GPM0.298506gal/MCF
SOP3-METHYLPENTANE0.0175MOL %
SOPAvg Molecular Weight18.46gm/mole
SOPBase Mol Percent100.765%v/v
SOPBENZENE0.001MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1058.2BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1075.7BTU
SOPBUTANE0.3992MOL %
SOPButane GPM0.253814gal/MCF
SOPCARBON DIOXIDE0.0079MOL %
SOPCYCLOHEXANE0.0135MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0002MOL %
SOPETHANE5.4086MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9975NA
SOPGasoline GPM0.172595gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0803MOL %
SOPHYDROGEN SULFIDENDMOL %ND
SOPISOBUTANE0.3929MOL %
SOPISOPENTANE0.1507MOL %
SOPM-+P-XYLENE0.0005MOL %
SOPMETHANE87.2872MOL %
SOPMETHYL CYCLOHEXANE0.0178MOL %
SOPN-HEXANE0.0407MOL %
SOPNITROGEN (N2)4.1781MOL %
SOPNONANE0.003MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0.0121MOL %
SOPOXYGEN (O2)NDMOL %ND
SOPPENTANE0.111MOL %
SOPPROPANE1.8594MOL %
SOPPropane GPM0.511203gal/MCF
SOPSample Pressure95PSIG
SOPSample Temperature99degrees F
SOPSPECIFIC GRAVITY0.6388RATIO_AIR
SOPTOLUENE0.0015MOL %
SOPTotal non gas liquids GPM0.937949gal/MCF

 Sample ID:   451193     Sample Date:  04/22/1999     Matrix:  WATER     Collection Point:       Type:  PIT     Lab:  Grand Junction Laboratories

Sample Results for Sample # 451193    Grand Junction Laboratories
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
UnSpecBARIUM0.7mg/L
UnSpecCALCIUM1430mg/L
UnSpecCHLORIDE10100mg/L
UnSpecIRON74.3mg/L
UnSpecMAGNESIUM79mg/L
UnSpecPH, LAB7.1SU
UnSpecRESISTIVITY0.355ohm/M
UnSpecSODIUM5000mg/L
UnSpecSULFATENDmg/LU
UnSpecTOTAL DISSOLVED SOLIDS19300mg/L