Sample Site ID463984
FacilityTypeOGProj Number
CountyJACKSON - 057LocationLot 11 6 6N80W
Elevation8219Lat/Long40.512758/-106.417277
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-057-06620Well Name:Damfino 0680 7-6H31
Well Status:PROperator Name:FULCRUM ENERGY OPERATING LLC
Location:Lot 11 6  6N  80W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   647702     Sample Date:  12/28/2022     Matrix:  GAS     Collection Point:  SEP     Type:  FBK     Lab:  SPL

Sample Results for Sample # 647702    SPL ID: 22120179-008A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-132,2,4-Trimethylpentane0.0037MOL %
GPA 2261-13BENZENE0.0226MOL %
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1396.4BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1421.1BTU/cuft dry
GPA 2261-13BUTANE2.8959MOL %
GPA 2261-13CARBON DIOXIDE1.2862MOL %
GPA 2261-13CYCLOHEXANE0.0743MOL %
GPA 2261-13Decane0.0771MOL %
GPA 2261-13ETHANE12.4149MOL %
GPA 2261-13ETHYLBENZENE0.0213MOL %
GPA 2261-13Heptane0.1033MOL %
GPA 2261-13Heptane0.3379MOL %
GPA 2261-13HYDROGEN SULFIDEMOL %
GPA 2261-13ISOBUTANE0.9202MOL %
GPA 2261-13ISOPENTANE0.5839MOL %
GPA 2261-13METHANE69.8656MOL %
GPA 2261-13N-HEXANE0.18MOL %
GPA 2261-13N-HEXANE0.2504MOL %
GPA 2261-13n-octane0.0659MOL %
GPA 2261-13n-octane0.2973MOL %
GPA 2261-13NITROGEN (N2)0.7388MOL %
GPA 2261-13NONANE0.0074MOL %
GPA 2261-13NONANE0.0435MOL %
GPA 2261-13PENTANE0.7062MOL %
GPA 2261-13PROPANE9.02MOL %
GPA 2261-13SPECIFIC GRAVITY0.8455Ratio
GPA 2261-13TOLUENE0.0468MOL %
GPA 2261-13TOTAL XYLENES0.0368MOL %

 Sample ID:   647700     Sample Date:  12/27/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  SPL

Sample Results for Sample # 647700    SPL ID: 22120179-005A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2,4-Trimethylpentane0.0391MOL %
SOP2,2-DIMETHYLBUTANE0.0085MOL %
SOP2,3-DIMETHYLBUTANE0.203MOL %
SOP2-methylhexane0.0554MOL %
SOP2-METHYLPENTANE1.3688MOL %
SOP3-methylhexane0.0383MOL %
SOP3-METHYLPENTANE0.236MOL %
SOPBENZENE0.0298MOL %
SOPBRITISH THERMAL UNITS- DRY BASIS1587.81BTU/cuft
SOPBUTANE3.4466MOL %
SOPC11 (mixed isomers)0.0009MOL %
SOPCARBON DIOXIDE0.3806MOL %
SOPCYCLOHEXANE0.3083MOL %
SOPCYCLOPENTANE0.1717MOL %
SOPDecane0.0017MOL %
SOPDecanes (mixed isomers)0.006MOL %
SOPETHENE7.3397MOL %
SOPETHYLBENZENE0.0021MOL %
SOPHeptane1.8895MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE1.2311MOL %
SOPISOPENTANE1.112MOL %
SOPM-+P-XYLENE0.0213MOL %
SOPMETHANE68.3664MOL %
SOPMETHYL CYCLOHEXANE0.3521MOL %
SOPMETHYLCYCLOPENTANE1.3766MOL %
SOPN-HEXANE0.623MOL %
SOPn-octane0.1005MOL %
SOPNITROGEN (N2)3.7355MOL %
SOPNONANE0.0409MOL %
SOPo-XYLENE0.0021MOL %
SOPOther Heptanes0.0868MOL %
SOPOther Nonanes0.076MOL %
SOPOther Octanes0.1866MOL %
SOPPENTANE1.3459MOL %
SOPPROPANE5.7302MOL %
SOPSPECIFIC GRAVITY0.9888RATIO_AIR
SOPTOLUENE0.0872MOL %

 Sample ID:   661549     Sample Date:  07/25/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 661549    Dolan Integration Group ID: DIG-036349
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1150BTU/cuft
SOPBUTANE1.498MOL %0.005
SOPC6+ (hexanes +)0.083MOL %0.005
SOPCARBON DIOXIDE0.076MOL %0.005
SOPDELTA 13C C1-53.4per mil
SOPDELTA 13C C2-36.5per mil
SOPDELTA 13C C3-31.5per mil
SOPDELTA 13C nC4-29.3per mil
SOPDELTA D C1-295per mil
SOPETHANE12.315MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.544MOL %0.005
SOPISOPENTANE0.238MOL %0.005
SOPMETHANE67.323MOL %0.005
SOPNITROGEN (N2)9.069MOL %0.005
SOPOXYGEN + ARGON2.152MOL %0.005
SOPPENTANE0.243MOL %0.005
SOPPROPANE6.46MOL %0.005
SOPSPECIFIC GRAVITY0.767No Unit

 Sample ID:   667149     Sample Date:  07/24/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667149    American Mobile Research ID: CR-17
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.066MOL %
GPA 2286Avg Molecular Weight22.0565gm/mole
GPA 2286BENZENE0.024MOL %
GPA 2286BRITISH THERMAL UNITS - SATURATED BASIS1258.86BTU
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1280.89BTU
GPA 2286BUTANE2.071MOL %
GPA 2286CARBON DIOXIDE1.642MOL %
GPA 2286COMPRESSIBILITY0.996077No Unit
GPA 2286CYCLOHEXANE0.059MOL %
GPA 2286CYCLOPENTANE0.015MOL %
GPA 2286DECANES +0.014MOL %
GPA 2286ETHENE8.321MOL %
GPA 2286ETHYLBENZENE0.006MOL %
GPA 2286HEPTANES, MIXED ISOMERS0.407MOL %
GPA 2286HYDROGEN SULFIDE0MOL %
GPA 2286ISOBUTANE0.58MOL %
GPA 2286ISOPENTANE0.472MOL %
GPA 2286METHANE78.524MOL %
GPA 2286METHYL CYCLOHEXANE0.097MOL %
GPA 2286N-HEXANE0.173MOL %
GPA 2286NITROGEN (N2)1.063MOL %
GPA 2286NONANE0.011MOL %
GPA 2286OCTANE, MIXED ISOMERS0.092MOL %
GPA 2286Other Hexanes0.228MOL %
GPA 2286PENTANE0.585MOL %
GPA 2286PROPANE5.481MOL %
GPA 2286Relative Density (air = 1)0.764546Ratio
GPA 2286SPECIFIC GRAVITY0.761546RATIO_AIR
GPA 2286TOLUENE0.037MOL %
GPA 2286Total non gas liquids GPM5.49419gal/MCF
GPA 2286TOTAL XYLENES0.032MOL %

 Sample ID:   667150     Sample Date:  07/24/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667150    American Mobile Research ID: CR-18
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
ASTM D5504CARBON DISULFIDENDmg/L<
ASTM D5504HYDROGEN SULFIDE1.121mg/L
ASTM D5504Sulfur DioxideNDmg/L<

 Sample ID:   661557     Sample Date:  07/24/2024     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 661557    Dolan Integration Group ID: DIG-036356
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %0.601%
CALCcarbon preference index (Hunt)0.996Ratio
CALCcarbon preference index (Marzi)1.017Ratio
CALCcycloparaffins %1.116%
CALCisoparaffins % (branched)0.876%
CALCisoprenoids %7.475%
CALCn paraffin %31.229%
CALCnC17/(nC18+nC29) ratio0.986Ratio
CALCnC18/(nC18+nC19) ratio0.545Ratio
CALCphytane/nC18 ratio0.442Ratio
CALCpristane/nC17 ratio0.6Ratio
CALCpristane/phytane ratio1.584Ratio
CALCresolved unknowns %56.95%
G02G1,1,3-Trimethylcyclopentane2.223AREA COUNT1
G02G1,1,3-Trimethylcyclopentane184ppm10
G02G1,1-dimethylcyclopentane1.209AREA COUNT1
G02G1,1-dimethylcyclopentane100ppm10
G02G1,2,3-trimethylcyclopentane2.712AREA COUNT1
G02G1,2,3-trimethylcyclopentane225ppm10
G02G1,2,4-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,4-trimethylcyclopentaneNDppm10ND
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentane0.118AREA COUNT1
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANE0.432AREA COUNT1
G02G2,3-DIMETHYLBUTANE36ppm10
G02G2,3-dimethylpentane1.92AREA COUNT1
G02G2,3-dimethylpentane156ppm10
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-methylhexane3.71AREA COUNT1
G02G2-methylhexane302ppm10
G02G2-METHYLPENTANE5.618AREA COUNT1
G02G2-METHYLPENTANE455ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane4.831AREA COUNT1
G02G3-methylhexane393ppm10
G02G3-METHYLPENTANE3.678AREA COUNT1
G02G3-METHYLPENTANE298ppm10
G02GBENZENE1.63AREA COUNT1
G02GBENZENE121ppm10
G02GBUTANE13.767AREA COUNT1
G02GBUTANE1102ppm10
G02Gcis-1,3-dimethylcyclopentane3.068AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane255ppm10
G02GCYCLOHEXANE6.63AREA COUNT1
G02GCYCLOHEXANE550ppm10
G02GCYCLOPENTANE2.36AREA COUNT1
G02GCYCLOPENTANE196ppm10
G02GDecane173.749AREA COUNT1
G02GDecane14215ppm10
G02GETHYLBENZENE5.44AREA COUNT1
G02GETHYLBENZENE438ppm10
G02Gethylcyclopentane1.938AREA COUNT1
G02Gethylcyclopentane161ppm10
G02GHeptane12.468AREA COUNT1
G02GHeptane1014ppm10
G02GHEXANES10.348AREA COUNT1
G02GHEXANES839ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANE2.54AREA COUNT1
G02GISOBUTANE197ppm10
G02GISOPENTANE8.006AREA COUNT1
G02GISOPENTANE628ppm10
G02Gisoprenoid C1024.301AREA COUNT1
G02Gisoprenoid C101988ppm10
G02Gisoprenoid C1152.603AREA COUNT1
G02Gisoprenoid C114308ppm10
G02Gisoprenoid C1380.562AREA COUNT1
G02Gisoprenoid C136611ppm10
G02Gisoprenoid C1467.768AREA COUNT1
G02Gisoprenoid C145567ppm10
G02Gisoprenoid C1554.348AREA COUNT1
G02Gisoprenoid C154469ppm10
G02Gisoprenoid C1671.912AREA COUNT1
G02Gisoprenoid C165913ppm10
G02Gisoprenoid C1872.134AREA COUNT1
G02Gisoprenoid C185937ppm10
G02Gisoprenoid C96.519AREA COUNT1
G02Gisoprenoid C9532ppm10
G02Gm-XYLENE15.2AREA COUNT1
G02Gm-XYLENE1213ppm10
G02GMETHYL CYCLOHEXANE21.439AREA COUNT1
G02GMETHYL CYCLOHEXANE1779ppm10
G02GMETHYLCYCLOPENTANE9.635AREA COUNT1
G02GMETHYLCYCLOPENTANE799ppm10
G02Gn-C11299.286AREA COUNT1
G02Gn-C1124510ppm10
G02Gn-C12282.406AREA COUNT1
G02Gn-C1223151ppm10
G02Gn-C13259.889AREA COUNT1
G02Gn-C1321327ppm10
G02Gn-C14209.99AREA COUNT1
G02Gn-C1417250ppm10
G02Gn-C15186.179AREA COUNT1
G02Gn-C1515309ppm10
G02Gn-C16177.032AREA COUNT1
G02Gn-C1614557ppm10
G02Gn-C17159.864AREA COUNT1
G02Gn-C1713159ppm10
G02Gn-C18136.912AREA COUNT1
G02Gn-C1811269ppm10
G02Gn-C19114.505AREA COUNT1
G02Gn-C199425ppm10
G02Gn-C20106.644AREA COUNT1
G02Gn-C208786ppm10
G02Gn-C2175.205AREA COUNT1
G02Gn-C216198ppm10
G02Gn-C2261.638AREA COUNT1
G02Gn-C225081ppm10
G02Gn-C2337.853AREA COUNT1
G02Gn-C233121ppm10
G02Gn-C2423.671AREA COUNT1
G02Gn-C241952ppm10
G02Gn-C257.947AREA COUNT1
G02Gn-C25656ppm10
G02Gn-C265.875AREA COUNT1
G02Gn-C26485ppm10
G02Gn-C273.294AREA COUNT1
G02Gn-C27272ppm10
G02Gn-C282.76AREA COUNT1
G02Gn-C28228ppm10
G02Gn-C292.264AREA COUNT1
G02Gn-C29187ppm10
G02Gn-C301.194AREA COUNT1
G02Gn-C3099ppm10
G02Gn-C310.938AREA COUNT1
G02Gn-C3177ppm10
G02Gn-c32NDAREA COUNT1ND
G02Gn-c32NDppm10ND
G02Gn-C33NDAREA COUNT1ND
G02Gn-C33NDppm10ND
G02Gn-C34NDAREA COUNT1ND
G02Gn-C34NDppm10ND
G02Gn-C35NDAREA COUNT1ND
G02Gn-C35NDppm10ND
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane19.8AREA COUNT1
G02Gn-octane1613ppm10
G02GNormal Alkane C953.418AREA COUNT1
G02GNormal Alkane C94361ppm10
G02Go-XYLENE11.605AREA COUNT1
G02Go-XYLENE944ppm10
G02Gp-XYLENE4.903AREA COUNT1
G02Gp-XYLENE407ppm10
G02GPENTANE11.593AREA COUNT1
G02GPENTANE935ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane60.524AREA COUNT1
G02Gphytane4987ppm10
G02Gpristane95.876AREA COUNT1
G02Gpristane7892ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE8.412AREA COUNT1
G02GTOLUENE653ppm10
G02Gtrans-1,2-dimethylcyclopentane5.786AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane480ppm10
G02Gtrans-1,3-dimethylcyclopentane2.858AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane237ppm10

 Sample ID:   655312     Sample Date:  05/24/2023     Matrix:  GAS     Collection Point:  PRD     Type:  OG     Lab:  EMPACT

Sample Results for Sample # 655312    EMPACT ID: Surprise Damfino 0680 S6 Pad Damfino 7-6H
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLPROPANE (neopentane)0.0014MOL %
SOPALCOHOLS0.0004MOL %
SOPBENZENE0.0148MOL %
SOPBUTANE2.826MOL %
SOPC8+0.0506MOL %
SOPCARBON DIOXIDE1.74MOL %
SOPCYCLOPENTANE0.051MOL %
SOPDecane0.0002MOL %
SOPETHANE12.0727MOL %
SOPETHYLBENZENE0.001MOL %
SOPHelium0.03MOL %
SOPHeptanes+0.0995MOL %
SOPHEXANES0.1173MOL %
SOPHYDROGEN0.09MOL %
SOPISOBUTANE0.9029MOL %
SOPISOPENTANE0.5324MOL %
SOPMETHANE70.8134MOL %
SOPMETHANOL0.0003MOL %
SOPNITROGEN (N2)0.71MOL %
SOPNonane PLus0.0009MOL %
SOPOXYGEN/ARGON RATIO0.01MOL %
SOPPENTANE0.5827MOL %
SOPPROPANE9.0528MOL %
SOPTOLUENE0.0092MOL %
SOPTOTAL XYLENES0.0029MOL %

 Sample ID:   666074     Sample Date:  02/19/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 666074    Pace Analytical ID: L1829065-02
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E365.4PHOSPHORUS46.2mg/L1
RSK-175ETHANE1.44mg/L0.013
RSK-175ETHENENDmg/L0.013U
RSK-175METHANE4.32mg/L0.01
SM2320BBICARBONATE ALKALINITY as CACO3421mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L20U
SM2320BTOTAL ALKALINITY AS CACO3421mg/L20
SM2540CTOTAL DISSOLVED SOLIDS49000mg/L1000
SM2540DTOTAL SUSPENDED SOLIDS20.4mg/L3.33
SM4500-P-EORTHOPHOSPHATE1.68mg/L0.15T8
SW6010BARIUM112mg/L0.1
SW6010BORON20.8mg/L0.2
SW6010CALCIUM789mg/L1
SW6010IRON63.8mg/L0.1
SW6010MAGNESIUM79.4mg/L1
SW6010MANGANESE0.872mg/L0.01
SW6010POTASSIUM58.6mg/L2
SW6010SELENIUMNDmg/L0.01U
SW6010SODIUM15700mg/L60
SW6010STRONTIUM140mg/L0.2
SW8015C10-C28 Diesel Range Organics50.5mg/L2
SW8015C28-C36 Motor Oil Range Organics12.9mg/L0.5
SW8015TVPH - Gasoline Range Organics29.6mg/L2
SW846 8260BBENZENE2.41mg/L0.1
SW846 8260BETHYLBENZENE0.165mg/L0.1
SW846 8260BNAPHTHALENENDmg/L0.5U
SW846 8260BTOLUENE2.04mg/L0.1
SW846 8260BTOTAL XYLENES0.723mg/L0.3
SW9040PH, LAB6.68SUT8
SW9050SPECIFIC CONDUCTIVITY68800umhos/cm10
SW9056BROMIDE322mg/L50
SW9056CHLORIDE25600mg/L500
SW9056FLUORIDENDmg/L7.5U
SW9056NITRATENDmg/L5U
SW9056NITRITENDmg/L5U
SW9056SULFATENDmg/L250U

 Sample ID:   666075     Sample Date:  02/19/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 666075    Pace Analytical ID: L1829065-05
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E904.0228RADIUM31.5pCi/L0.553
SM7500-RN-B226RADIUM50.5pCi/L0.13

 Sample ID:   656910     Sample Date:  02/02/2024     Matrix:  WATER     Collection Point:  SEP     Type:  SEP     Lab:  

Sample Results for Sample # 656910 ID: 356003
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E170.1Sample Temperature70degrees F
E200.7ALUMINUM0.21mg/L
E200.7AMMONIA0mg/L
E200.7BARIUM47.34mg/L
E200.7CALCIUM592.89mg/L
E200.7IRON19.89mg/L
E200.7LEAD0mg/L
E200.7LITHIUM2.17mg/L
E200.7MAGNESIUM51.94mg/L
E200.7MANGANESE0.17mg/L
E200.7POTASSIUM29.35mg/L
E200.7SODIUM17000mg/L
E200.7STRONTIUM63.56mg/L
E200.7ZINC0.082mg/L
E200.8TOTAL DISSOLVED SOLIDS, CALCULATED LAB46633mg/L
E300.0ACETIC ACID0mg/L
E300.0BICARBONATE ALKALINITY as CACO3439.2mg/L as CaCO3
E300.0BORON10.29mg/L
E300.0BROMIDE0mg/L
E300.0CARBON DIOXIDE200mg/L
E300.0CARBONATE ALKALINITY AS CACO30mg/L as CaCO3
E300.0CHLORIDE27300mg/L
E300.0FLUORIDE0mg/L
E300.0HYDROGEN SULFIDE3.4mg/L
E300.0NITRATE0mg/L
E300.0PHOSPHATE0mg/L
E300.0SILICA (SiO2)0mg/L
E300.0SULFATE0mg/L
SM2510BRESISTIVITY18.24ohm/M
SM2510BSPECIFIC CONDUCTIVITY54834uS/cm
SM2710FSPECIFIC GRAVITY1.028RATIO_AIR
SM4500-H+ BPH, LAB6.68pH Units
SOPPRESSURE0.0313PSIG
SOPPRESSURE0.8171PSIG
SOPPRESSURE14.6959PSIG

 Sample ID:   647713     Sample Date:  01/23/2023     Matrix:  GAS     Collection Point:  SEP     Type:  PRDL     Lab:  SPL

Sample Results for Sample # 647713    SPL ID: 23010155-008A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2,4-Trimethylpentane0.0053MOL %
SOP2,2-DIMETHYLBUTANE0.0042MOL %
SOP2,3-DIMETHYLBUTANE0.1586MOL %
SOP2-methylhexane0.0242MOL %
SOP2-METHYLPENTANE1.0694MOL %
SOP3-methylhexane0.0167MOL %
SOP3-METHYLPENTANE0.1411MOL %
SOPBENZENE0.0074MOL %
SOPBRITISH THERMAL UNITS- DRY BASIS2205.53BTU/cuft
SOPBUTANE10.8756MOL %
SOPC11 (mixed isomers)0.0002MOL %
SOPCARBON DIOXIDE1.1604MOL %
SOPCYCLOHEXANE0.07MOL %
SOPCYCLOPENTANE0.1341MOL %
SOPDecane0.0005MOL %
SOPDecanes (mixed isomers)0.0016MOL %
SOPETHENE21.1173MOL %
SOPETHYLBENZENE0.0007MOL %
SOPHeptane0.8236MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE3.4325MOL %
SOPISOPENTANE1.951MOL %
SOPM-+P-XYLENE0.0022MOL %
SOPMETHANE26.5012MOL %
SOPMETHYL CYCLOHEXANE0.0476MOL %
SOPMETHYLCYCLOPENTANE0.6001MOL %
SOPN-HEXANE0.3063MOL %
SOPn-octane0.0149MOL %
SOPNITROGEN (N2)0.1648MOL %
SOPNONANE0.004MOL %
SOPo-XYLENE0.0004MOL %
SOPOther Heptanes0.0379MOL %
SOPOther Nonanes0.0075MOL %
SOPOther Octanes0.0276MOL %
SOPPENTANE2.1151MOL %
SOPPROPANE28.9691MOL %
SOPSPECIFIC GRAVITY1.3207RATIO_AIR
SOPTOLUENE0.2071MOL %