Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#451274 Information View DocsDoc View GISGIS
Sample Site ID451274
FacilityTypeOGProj Number
CountyWELD - 123LocationSESE 7 5N61W
Elevation4564Lat/Long40.409539/-104.246557
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-45065Well Name:Pronghorn U-Y-18HNB
Well Status:PROperator Name:BONANZA CREEK ENERGY OPERATING COMPANY LLC
Location:SESE  7  5N  61W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   642463     Sample Date:  09/27/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 642463    SPL ID: 22090201-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1564BTU/cuft
SOPBUTANE3.8452MOL %0.001
SOPCARBON DIOXIDE2.336MOL %0.001
SOPETHENE12.0767MOL %0.001
SOPHEXANES3.5781MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %
SOPISOBUTANE0.9867MOL %0.001
SOPISOPENTANE1.6096MOL %0.001
SOPMETHANE61.1812MOL %0.001
SOPNITROGEN (N2)3.4494MOL %0.001
SOPPENTANE2.5105MOL %0.001
SOPPROPANE8.4265MOL %0.001
SOPSPECIFIC GRAVITY0.9823RATIO_AIR

 Sample ID:   642498     Sample Date:  09/23/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 642498    SPL ID: 22090183-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1325BTU/cuft
SOPBUTANE2.3954MOL %0.001
SOPCARBON DIOXIDE2.6634MOL %0.001
SOPETHENE13.3399MOL %0.001
SOPHEXANES0.3469MOL %0.001
SOPHYDROGEN SULFIDE0.0002MOL %
SOPISOBUTANE0.8298MOL %0.001
SOPISOPENTANE0.2869MOL %0.001
SOPMETHANE70.2579MOL %0.001
SOPNITROGEN (N2)0.6728MOL %0.001
SOPPENTANE0.3119MOL %0.001
SOPPROPANE8.8949MOL %0.001
SOPSPECIFIC GRAVITY0.804RATIO_AIR

 Sample ID:   628417     Sample Date:  09/21/2021     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 628417    SPL ID: 21090182-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1399BTU/cuft
SOPBUTANE2.6333MOL %0.001
SOPCARBON DIOXIDE2.2497MOL %0.001
SOPETHENE13.3543MOL %0.001
SOPHEXANES1.121MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %0.0001
SOPISOBUTANE1.0526MOL %0.001
SOPISOPENTANE0.4182MOL %0.001
SOPMETHANE68.0068MOL %0.001
SOPNITROGEN (N2)0.6817MOL %0.001
SOPPENTANE0.5432MOL %0.001
SOPPROPANE9.9391MOL %0.001
SOPSPECIFIC GRAVITY0.8452RATIO_AIR

 Sample ID:   628416     Sample Date:  09/20/2021     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 628416    SPL ID: 21090182-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1371BTU/cuft
SOPBUTANE2.9591MOL %0.001
SOPCARBON DIOXIDE2.4545MOL %0.001
SOPETHENE13.1418MOL %0.001
SOPHEXANES0.6503MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %0.0001
SOPISOBUTANE0.9386MOL %0.001
SOPISOPENTANE0.5298MOL %0.001
SOPMETHANE69.2122MOL %0.001
SOPNITROGEN (N2)0.6481MOL %0.001
SOPPENTANE0.6802MOL %0.001
SOPPROPANE8.7853MOL %0.001
SOPSPECIFIC GRAVITY0.83RATIO_AIR

 Sample ID:   652339     Sample Date:  09/11/2023     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 652339    SPL ID: 23090222-006A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1327BTU/cuft
SOPBUTANE1.9718MOL %0.001
SOPCARBON DIOXIDE2.3887MOL %0.001
SOPETHENE13.3658MOL %0.001
SOPHEXANES0.8068MOL %0.001
SOPHYDROGEN SULFIDE0.0003MOL %
SOPISOBUTANE0.6789MOL %0.001
SOPISOPENTANE0.3087MOL %0.001
SOPMETHANE71.0484MOL %0.001
SOPNITROGEN (N2)0.7657MOL %0.001
SOPPENTANE0.4019MOL %0.001
SOPPROPANE8.263MOL %0.001
SOPSPECIFIC GRAVITY0.8018RATIO_AIR

 Sample ID:   652340     Sample Date:  09/08/2023     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 652340    SPL ID: 23090222-005A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1401BTU/cuft
SOPBUTANE2.8778MOL %0.001
SOPCARBON DIOXIDE2.4554MOL %0.001
SOPETHENE13.6523MOL %0.001
SOPHEXANES1.1126MOL %0.001
SOPHYDROGEN SULFIDE0.0002MOL %
SOPISOBUTANE0.9193MOL %0.001
SOPISOPENTANE0.5335MOL %0.001
SOPMETHANE67.8596MOL %0.001
SOPNITROGEN (N2)0.6326MOL %0.001
SOPPENTANE0.7271MOL %0.001
SOPPROPANE9.2296MOL %0.001
SOPSPECIFIC GRAVITY0.8488RATIO_AIR