Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#450660 Information View DocsDoc View GISGIS
Sample Site ID450660
FacilityTypeOGProj Number
CountyWELD - 123LocationNENE 26 5N65W
Elevation4641Lat/Long40.37422/-104.62245
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-44860Well Name:Geib 26V-314
Well Status:PROperator Name:PDC ENERGY INC
Location:NENE  26 5N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   620482     Sample Date:  09/30/2020     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 620482    Dolan Integration Group ID: DIG-023757
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1239BTU/cuft
SOPBUTANE1.64MOL %0.005
SOPC6+ (hexanes +)0.51MOL %0.005
SOPCARBON DIOXIDE0.46MOL %0.005
SOPDELTA 13C C1-45.8per mil
SOPDELTA 13C C2-30.9per mil
SOPDELTA 13C C3-27.5per mil
SOPDELTA 13C iC4-31.6per mil
SOPDelta 13C iC5-28.6per mil
SOPDELTA 13C nC4-27.8per mil
SOPDelta 13C nC5-28per mil
SOPDELTA D C1-236per mil
SOPETHANE11.37MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.02MOL %0.005
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.77MOL %0.005
SOPISOPENTANE0.44MOL %0.005
SOPMETHANE76.4MOL %0.005
SOPNITROGEN (N2)2.37MOL %0.005
SOPOXYGEN + ARGON0.54MOL %0.005
SOPPENTANE0.51MOL %0.005
SOPPROPANE4.97MOL %0.005
SOPSPECIFIC GRAVITY0.74No Unit

 Sample ID:   620483     Sample Date:  09/30/2020     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 620483    Dolan Integration Group ID: DIG-023758
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1231BTU/cuft
SOPBUTANE1.53MOL %0.005
SOPC6+ (hexanes +)0.33MOL %0.005
SOPCARBON DIOXIDE2.88MOL %0.005
SOPDELTA 13C C1-45.5per mil
SOPDELTA 13C C2-30.8per mil
SOPDELTA 13C C3-27.7per mil
SOPDELTA 13C CO22.5per mil
SOPDELTA 13C iC4-31.7per mil
SOPDelta 13C iC5-29per mil
SOPDELTA 13C nC4-27.7per mil
SOPDelta 13C nC5-28.9per mil
SOPDELTA D C1-232per mil
SOPETHANE12.55MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.74MOL %0.005
SOPISOPENTANE0.38MOL %0.005
SOPMETHANE75.11MOL %0.005
SOPNITROGEN (N2)0.8MOL %0.005
SOPOXYGEN + ARGON0.16MOL %0.005
SOPPENTANE0.39MOL %0.005
SOPPROPANE5.13MOL %0.005
SOPSPECIFIC GRAVITY0.752No Unit

 Sample ID:   672000     Sample Date:  09/12/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 672000    Dolan Integration Group ID: DIG-041319
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS853BTU/cuft
SOPBUTANE0.91MOL %0.005
SOPC6+ (hexanes +)0.084MOL %0.005
SOPCARBON DIOXIDE0.071MOL %0.005
SOPDELTA 13C C1-42.5per mil
SOPDELTA 13C C2-29.6per mil
SOPDELTA 13C C3-26.4per mil
SOPDELTA 13C iC4-29.6per mil
SOPDELTA 13C nC4-26.4per mil
SOPDelta 13C nC5-25.8per mil
SOPDELTA D C1-237per mil
SOPETHANE8.08MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.436MOL %0.005
SOPISOPENTANE0.231MOL %0.005
SOPMETHANE55.831MOL %0.005
SOPNITROGEN (N2)24.329MOL %0.005
SOPOXYGEN + ARGON6.643MOL %0.005
SOPPENTANE0.259MOL %0.005
SOPPROPANE3.126MOL %0.005
SOPSPECIFIC GRAVITY0.792No Unit

 Sample ID:   672001     Sample Date:  09/12/2025     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 672001    Dolan Integration Group ID: DIG-041320
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS818BTU/cuft
SOPBUTANE0.39MOL %0.005
SOPC6+ (hexanes +)0.019MOL %0.005
SOPCARBON DIOXIDE1.747MOL %0.005
SOPDELTA 13C C1-39.4per mil
SOPDELTA 13C C2-28.5per mil
SOPDELTA 13C C3-26.1per mil
SOPDELTA 13C CO23.3per mil
SOPDELTA 13C iC4-29.6per mil
SOPDELTA 13C nC4-25.9per mil
SOPDELTA D C1-232per mil
SOPETHANE8.363MOL %0.005
SOPETHENE0.022MOL %0.005
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.125MOL %0.005
SOPISOBUTANE0.262MOL %0.005
SOPISOPENTANE0.031MOL %0.005
SOPMETHANE57.277MOL %0.005
SOPNITROGEN (N2)22.887MOL %0.005
SOPOXYGEN + ARGON6.242MOL %0.005
SOPPENTANE0.02MOL %0.005
SOPPROPANE2.613MOL %0.005
SOPSPECIFIC GRAVITY0.777No Unit

 Sample ID:   662441     Sample Date:  08/28/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 662441    Dolan Integration Group ID: DIG-036926
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1239BTU/cuft
SOPBUTANE1.544MOL %0.005
SOPC6+ (hexanes +)0.336MOL %0.005
SOPCARBON DIOXIDE0.148MOL %0.005
SOPDELTA 13C C1-45.9per mil
SOPDELTA 13C C2-29.6per mil
SOPDELTA 13C C3-25.6per mil
SOPDELTA 13C iC4-28.4per mil
SOPDELTA 13C nC4-25.9per mil
SOPDELTA D C1-239per mil
SOPETHANE11.706MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.744MOL %0.005
SOPISOPENTANE0.383MOL %0.005
SOPMETHANE77.569MOL %0.005
SOPNITROGEN (N2)1.791MOL %0.005
SOPOXYGEN + ARGON0.38MOL %0.005
SOPPENTANE0.417MOL %0.005
SOPPROPANE4.981MOL %0.005
SOPSPECIFIC GRAVITY0.727No Unit

 Sample ID:   662442     Sample Date:  08/28/2024     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 662442    Dolan Integration Group ID: DIG-036927
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1251BTU/cuft
SOPBUTANE1.807MOL %0.005
SOPC6+ (hexanes +)0.243MOL %0.005
SOPCARBON DIOXIDE2.605MOL %0.005
SOPDELTA 13C C1-45.9per mil
SOPDELTA 13C C2-29.6per mil
SOPDELTA 13C C3-26.8per mil
SOPDELTA 13C CO23.8per mil
SOPDELTA 13C iC4-29per mil
SOPDelta 13C iC5-26per mil
SOPDELTA 13C nC4-26.4per mil
SOPDelta 13C nC5-26.8per mil
SOPDELTA D C1-236per mil
SOPETHANE12.574MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.83MOL %0.005
SOPISOPENTANE0.483MOL %0.005
SOPMETHANE74.98MOL %0.005
SOPNITROGEN (N2)0.59MOL %0.005
SOPOXYGEN + ARGON0.078MOL %0.005
SOPPENTANE0.514MOL %0.005
SOPPROPANE5.296MOL %0.005
SOPSPECIFIC GRAVITY0.758No Unit

 Sample ID:   638976     Sample Date:  06/08/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 638976    Dolan Integration Group ID: DIG-028170
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1261BTU/cuft
SOPBUTANE1.707MOL %0.005
SOPC6+ (hexanes +)0.438MOL %0.005
SOPCARBON DIOXIDE0.251MOL %0.005
SOPDELTA 13C C1-46.1per mil
SOPDELTA 13C C2-29.4per mil
SOPDELTA 13C C3-26.7per mil
SOPDELTA 13C CO2-6.7per mil
SOPDELTA 13C iC4-29.6per mil
SOPDELTA 13C nC4-26.8per mil
SOPDelta 13C nC5-28.6per mil
SOPDELTA D C1-237per mil
SOPETHANE11.592MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.794MOL %0.005
SOPISOPENTANE0.474MOL %0.005
SOPMETHANE77.746MOL %0.005
SOPNITROGEN (N2)1.201MOL %0.005
SOPOXYGEN + ARGON0.186MOL %0.005
SOPPENTANE0.542MOL %0.005
SOPPROPANE5.069MOL %0.005
SOPSPECIFIC GRAVITY0.734No Unit

 Sample ID:   638977     Sample Date:  06/08/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 638977    Dolan Integration Group ID: DIG-028171
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1250BTU/cuft
SOPBUTANE1.933MOL %0.005
SOPC6+ (hexanes +)0.414MOL %0.005
SOPCARBON DIOXIDE2.599MOL %0.005
SOPDELTA 13C C1-45.8per mil
SOPDELTA 13C C2-29.5per mil
SOPDELTA 13C C3-27.1per mil
SOPDELTA 13C CO23.9per mil
SOPDELTA 13C iC4-30.5per mil
SOPDELTA 13C nC4-26.6per mil
SOPDelta 13C nC5-27.2per mil
SOPDELTA D C1-234per mil
SOPETHANE12.437MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.871MOL %0.005
SOPISOPENTANE0.545MOL %0.005
SOPMETHANE73.003MOL %0.005
SOPNITROGEN (N2)1.805MOL %0.005
SOPOXYGEN + ARGON0.38MOL %0.005
SOPPENTANE0.59MOL %0.005
SOPPROPANE5.423MOL %0.005
SOPSPECIFIC GRAVITY0.774No Unit

 Sample ID:   648097     Sample Date:  03/23/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 648097    Dolan Integration Group ID: DIG-031398
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1258BTU/cuft
SOPBUTANE1.66MOL %0.005
SOPC6+ (hexanes +)0.33MOL %0.005
SOPCARBON DIOXIDE0.037MOL %0.005
SOPDELTA 13C C1-46.1per mil
SOPDELTA 13C C2-29.5per mil
SOPDELTA 13C C3-26.5per mil
SOPDELTA 13C nC4-24.6per mil
SOPDELTA D C1-236per mil
SOPETHANE11.565MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.789MOL %0.005
SOPISOPENTANE0.429MOL %0.005
SOPMETHANE78.699MOL %0.005
SOPNITROGEN (N2)0.86MOL %0.005
SOPOXYGEN + ARGON0.097MOL %0.005
SOPPENTANE0.462MOL %0.005
SOPPROPANE5.071MOL %0.005
SOPSPECIFIC GRAVITY0.724No Unit

 Sample ID:   648098     Sample Date:  03/23/2023     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 648098    Dolan Integration Group ID: DIG-031399
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1262BTU/cuft
SOPBUTANE1.998MOL %0.005
SOPC6+ (hexanes +)0.408MOL %0.005
SOPCARBON DIOXIDE2.363MOL %0.005
SOPDELTA 13C C1-44per mil
SOPDELTA 13C C2-29per mil
SOPDELTA 13C C3-26.7per mil
SOPDELTA 13C CO25.7per mil
SOPDELTA 13C nC4-26.4per mil
SOPDelta 13C nC5-27per mil
SOPDELTA D C1-230per mil
SOPETHANE12.657MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.892MOL %0.005
SOPISOPENTANE0.554MOL %0.005
SOPMETHANE73.175MOL %0.005
SOPNITROGEN (N2)1.496MOL %0.005
SOPOXYGEN + ARGON0.327MOL %0.005
SOPPENTANE0.587MOL %0.005
SOPPROPANE5.542MOL %0.005
SOPSPECIFIC GRAVITY0.774No Unit