Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#448966 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID448966
FacilityTypeOGProj Number
CountyJACKSON - 057LocationLot 4 18 7N80W
Elevation8207Lat/Long40.571458/-106.424368
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-057-06590Well Name:Peters 0781 10-13H12
Well Status:PROperator Name:FULCRUM ENERGY OPERATING LLC
Location:LOT4  18 7N  80W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   645669     Sample Date:  12/20/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 645669    Dolan Integration Group ID: DIG-030573
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1156BTU/cuft
SOPBUTANE1.732MOL %0.005
SOPC6+ (hexanes +)0.039MOL %0.005
SOPCARBON DIOXIDE2.2MOL %0.005
SOPDELTA 13C C1-57.2per mil
SOPDELTA 13C C2-38.2per mil
SOPDELTA 13C C3-33.7per mil
SOPDELTA 13C CO2-3.8per mil
SOPDELTA 13C nC4-31per mil
SOPDELTA D C1-260per mil
SOPETHANE5.602MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.029MOL %0.005
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.528MOL %0.005
SOPISOPENTANE0.199MOL %0.005
SOPMETHANE81.81MOL %0.005
SOPNITROGEN (N2)2.062MOL %0.005
SOPOXYGEN + ARGON0.015MOL %0.005
SOPPENTANE0.152MOL %0.005
SOPPROPANE5.535MOL %0.005
SOPSPECIFIC GRAVITY0.705No Unit

 Sample ID:   645934     Sample Date:  12/13/2022     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 645934    SPL ID: 22120128-005A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.0003MOL %
GPA 2286BENZENE0.0045MOL %
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1186.1BTU/cuft
GPA 2286BUTANE1.8488MOL %
GPA 2286C11 (mixed isomers)MOL %
GPA 2286C12 (mixed isomers)MOL %
GPA 2286C13 (mixed isomers)MOL %
GPA 2286CARBON DIOXIDE2.2841MOL %
GPA 2286CYCLOHEXANE0.0085MOL %
GPA 2286Decane0.0033MOL %
GPA 2286Decanes (mixed isomers)MOL %
GPA 2286ETHENE5.5238MOL %
GPA 2286ETHYLBENZENE0.0069MOL %
GPA 2286Heptane0.0066MOL %
GPA 2286ISOBUTANE0.5335MOL %
GPA 2286ISOPENTANE0.3638MOL %
GPA 2286METHANE81.837MOL %
GPA 2286N-HEXANE0.0406MOL %
GPA 2286n-octane0.015MOL %
GPA 2286NITROGEN (N2)1.7609MOL %
GPA 2286NONANE0.0042MOL %
GPA 2286Other Heptanes0.0527MOL %
GPA 2286Other Hexanes0.0795MOL %
GPA 2286Other Nonanes0.0205MOL %
GPA 2286Other Octanes0.0373MOL %
GPA 2286PENTANE0.3526MOL %
GPA 2286PROPANE5.1406MOL %
GPA 2286SPECIFIC GRAVITY0.7209RATIO_AIR
GPA 2286Tetradecanes +MOL %
GPA 2286TOLUENE0.0046MOL %
GPA 2286TOTAL XYLENES0.0162MOL %

 Sample ID:   609985     Sample Date:  10/07/2019     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  

Sample Results for Sample # 609985
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDHYDROGEN SULFIDE, FIELD39ppm

 Sample ID:   613919     Sample Date:  09/23/2019     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 613919    SPL ID: 19100025-005A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.003MOL %
GPA 2286BENZENE0.014MOL %
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1302.3BTU/cuft
GPA 2286BUTANE2.83MOL %
GPA 2286C11 (mixed isomers)0.027MOL %
GPA 2286CARBON DIOXIDE2.126MOL %
GPA 2286CYCLOHEXANE0.043MOL %
GPA 2286Decane0.003MOL %
GPA 2286Decanes (mixed isomers)0.037MOL %
GPA 2286ETHANE6.355MOL %
GPA 2286ETHYLBENZENE0.009MOL %
GPA 2286HEPTANES, MIXED ISOMERS0.047MOL %
GPA 2286ISOBUTANE0.797MOL %
GPA 2286ISOPENTANE0.614MOL %
GPA 2286METHANE76.856MOL %
GPA 2286N-HEXANE0.151MOL %
GPA 2286n-octane0.009MOL %
GPA 2286NITROGEN (N2)1.623MOL %
GPA 2286NONANE0.013MOL %
GPA 2286Other Heptanes0.263MOL %
GPA 2286Other Hexanes0.271MOL %
GPA 2286Other Nonanes0.079MOL %
GPA 2286Other Octanes0.138MOL %
GPA 2286PENTANE0.655MOL %
GPA 2286PROPANE7.004MOL %
GPA 2286SPECIFIC GRAVITY0.7921RATIO_AIR
GPA 2286TOTAL XYLENES0.016MOL %

 Sample ID:   620276     Sample Date:  09/09/2020     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 620276    SPL ID: 20090118-003A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1340.2BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1364BTU/cuft dry
GPA 2261-13BUTANE2.3802MOL %
GPA 2261-13C6+ (hexanes +)0.5859MOL %
GPA 2261-13CARBON DIOXIDE2.1618MOL %
GPA 2261-13ETHANE5.5488MOL %
GPA 2261-13ISOBUTANE0.6446MOL %
GPA 2261-13ISOPENTANE0.5344MOL %
GPA 2261-13METHANE77.0572MOL %
GPA 2261-13NITROGEN (N2)1.5717MOL %
GPA 2261-13PENTANE1.3145MOL %
GPA 2261-13PROPANE5.6517MOL %
GPA 2261-13SPECIFIC GRAVITY0.8356Ratio

 Sample ID:   667166     Sample Date:  07/24/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667166    American Mobile Research ID: CR-56
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
ASTM D5504CARBON DISULFIDE0.035mg/L
ASTM D5504HYDROGEN SULFIDE0.249mg/L
ASTM D5504Sulfur DioxideNDmg/L<

 Sample ID:   667165     Sample Date:  07/24/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667165    American Mobile Research ID: CR-55
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.015MOL %
GPA 2286Avg Molecular Weight20.5665gm/mole
GPA 2286BENZENE0.005MOL %
GPA 2286BRITISH THERMAL UNITS - SATURATED BASIS1142.98BTU
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1162.96BTU
GPA 2286BUTANE1.519MOL %
GPA 2286CARBON DIOXIDE2.872MOL %
GPA 2286COMPRESSIBILITY0.99681No Unit
GPA 2286CYCLOHEXANE0.011MOL %
GPA 2286CYCLOPENTANE0.006MOL %
GPA 2286DECANES +0.003MOL %
GPA 2286ETHENE6.083MOL %
GPA 2286ETHYLBENZENE0.001MOL %
GPA 2286HEPTANES, MIXED ISOMERS0.086MOL %
GPA 2286HYDROGEN SULFIDE0MOL %
GPA 2286ISOBUTANE0.432MOL %
GPA 2286ISOPENTANE0.258MOL %
GPA 2286METHANE82.03MOL %
GPA 2286METHYL CYCLOHEXANE0.017MOL %
GPA 2286N-HEXANE0.061MOL %
GPA 2286NITROGEN (N2)1.457MOL %
GPA 2286NONANE0.002MOL %
GPA 2286OCTANE, MIXED ISOMERS0.011MOL %
GPA 2286Other Hexanes0.089MOL %
GPA 2286PENTANE0.254MOL %
GPA 2286PROPANE4.781MOL %
GPA 2286Relative Density (air = 1)0.712375Ratio
GPA 2286SPECIFIC GRAVITY0.710102RATIO_AIR
GPA 2286TOLUENE0.003MOL %
GPA 2286Total non gas liquids GPM3.87489gal/MCF
GPA 2286TOTAL XYLENES0.004MOL %

 Sample ID:   606788     Sample Date:  05/15/2019     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 606788    SPL ID: 2500-19050084-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDHYDROGEN SULFIDE, FIELD120ppm>
GPA 2172BRITISH THERMAL UNITS - SATURATED BASIS1592.4BTU
GPA 2172BRITISH THERMAL UNITS- DRY BASIS1620.6BTU
GPA 2172Relative Density (air = 1)0.994Ratio
GPA 22862,2,4-Trimethylpentane0.013MOL %
GPA 22862-methylhexane1.158MOL %
GPA 22862-methyloctane0.191MOL %
GPA 22862-METHYLPENTANE0.935MOL %
GPA 2286BENZENE0.055MOL %
GPA 2286BUTANE4.89MOL %
GPA 2286CARBON DIOXIDE2.215MOL %
GPA 2286CYCLOHEXANE0.197MOL %
GPA 2286DECANES +0.078MOL %
GPA 2286ETHANE8.427MOL %
GPA 2286ETHYLBENZENE0.034MOL %
GPA 2286Heptane0.23MOL %
GPA 2286ISOBUTANE1.316MOL %
GPA 2286ISOPENTANE1.334MOL %
GPA 2286METHANE64.4MOL %
GPA 2286N-HEXANE0.599MOL %
GPA 2286n-octane0.096MOL %
GPA 2286NITROGEN (N2)1.017MOL %
GPA 2286NONANE0.038MOL %
GPA 2286Other Octanes0.628MOL %
GPA 2286PENTANE1.593MOL %
GPA 2286PROPANE10.426MOL %
GPA 2286TOLUENE0.075MOL %
GPA 2286TOTAL XYLENES0.055MOL %

 Sample ID:   634016     Sample Date:  02/08/2022     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 634016    Dolan Integration Group ID: DIG-027315
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %0.479%
CALCcarbon preference index (Hunt)1.014Ratio
CALCcarbon preference index (Marzi)0.939Ratio
CALCcycloparaffins %0.352%
CALCisoparaffins % (branched)0.41%
CALCisoprenoids %7.162%
CALCn paraffin %26.302%
CALCnC17/(nC18+nC29) ratio0.957Ratio
CALCnC18/(nC18+nC19) ratio0.566Ratio
CALCphytane/nC18 ratio0.434Ratio
CALCpristane/nC17 ratio0.549Ratio
CALCpristane/phytane ratio1.634Ratio
CALCresolved unknowns %63.04%
G02G1,1,3-TrimethylcyclopentaneNDAREA COUNT1ND
G02G1,1,3-TrimethylcyclopentaneNDppm10ND
G02G1,1-dimethylcyclopentaneNDAREA COUNT1ND
G02G1,1-dimethylcyclopentaneNDppm10ND
G02G1,2,3-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,3-trimethylcyclopentaneNDppm10ND
G02G1,2,4-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,4-trimethylcyclopentaneNDppm10ND
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentaneNDAREA COUNT1ND
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,3-DIMETHYLBUTANENDppm10ND
G02G2,3-dimethylpentaneNDAREA COUNT1ND
G02G2,3-dimethylpentaneNDppm10ND
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-methylhexaneNDAREA COUNT1ND
G02G2-methylhexaneNDppm10ND
G02G2-METHYLPENTANENDAREA COUNT1ND
G02G2-METHYLPENTANENDppm10ND
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane1.081AREA COUNT1
G02G3-methylhexane43ppm10
G02G3-METHYLPENTANENDAREA COUNT1ND
G02G3-METHYLPENTANENDppm10ND
G02GBENZENENDAREA COUNT1ND
G02GBENZENENDppm10ND
G02GBUTANENDAREA COUNT1ND
G02GBUTANENDppm10ND
G02Gcis-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gcis-1,3-dimethylcyclopentaneNDppm10ND
G02GCYCLOHEXANE1.289AREA COUNT1
G02GCYCLOHEXANE52ppm10
G02GCYCLOPENTANENDAREA COUNT1ND
G02GCYCLOPENTANENDppm10ND
G02GDecane91.67AREA COUNT1
G02GDecane3667ppm10
G02GETHYLBENZENE3.676AREA COUNT1
G02GETHYLBENZENE145ppm10
G02GethylcyclopentaneNDAREA COUNT1ND
G02GethylcyclopentaneNDppm10ND
G02GHeptane2.12AREA COUNT1
G02GHeptane84ppm10
G02GHEXANESNDAREA COUNT1ND
G02GHEXANESNDppm10ND
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANENDAREA COUNT1ND
G02GISOBUTANENDppm10ND
G02GISOPENTANENDAREA COUNT1ND
G02GISOPENTANENDppm10ND
G02Gisoprenoid C1015.224AREA COUNT1
G02Gisoprenoid C10609ppm10
G02Gisoprenoid C1133.661AREA COUNT1
G02Gisoprenoid C111348ppm10
G02Gisoprenoid C1354.578AREA COUNT1
G02Gisoprenoid C132190ppm10
G02Gisoprenoid C1450.299AREA COUNT1
G02Gisoprenoid C142020ppm10
G02Gisoprenoid C1537.766AREA COUNT1
G02Gisoprenoid C151518ppm10
G02Gisoprenoid C1647.91AREA COUNT1
G02Gisoprenoid C161926ppm10
G02Gisoprenoid C1846.131AREA COUNT1
G02Gisoprenoid C181856ppm10
G02Gisoprenoid C92.938AREA COUNT1
G02Gisoprenoid C9117ppm10
G02Gm-XYLENE8.527AREA COUNT1
G02Gm-XYLENE333ppm10
G02GMETHYL CYCLOHEXANE6.042AREA COUNT1
G02GMETHYL CYCLOHEXANE245ppm10
G02GMETHYLCYCLOPENTANE1.039AREA COUNT1
G02GMETHYLCYCLOPENTANE42ppm10
G02Gn-C11166.63AREA COUNT1
G02Gn-C116672ppm10
G02Gn-C12154.871AREA COUNT1
G02Gn-C126207ppm10
G02Gn-C13154.749AREA COUNT1
G02Gn-C136208ppm10
G02Gn-C14127.109AREA COUNT1
G02Gn-C145105ppm10
G02Gn-C15125.205AREA COUNT1
G02Gn-C155033ppm10
G02Gn-C1693.298AREA COUNT1
G02Gn-C163751ppm10
G02Gn-C1790.013AREA COUNT1
G02Gn-C173622ppm10
G02Gn-C1869.754AREA COUNT1
G02Gn-C182807ppm10
G02Gn-C1953.59AREA COUNT1
G02Gn-C192157ppm10
G02Gn-C2050.67AREA COUNT1
G02Gn-C202041ppm10
G02Gn-C2131.823AREA COUNT1
G02Gn-C211282ppm10
G02Gn-C2223.717AREA COUNT1
G02Gn-C22956ppm10
G02Gn-C2315.448AREA COUNT1
G02Gn-C23623ppm10
G02Gn-C2411.185AREA COUNT1
G02Gn-C24451ppm10
G02Gn-C258.938AREA COUNT1
G02Gn-C25361ppm10
G02Gn-C267.925AREA COUNT1
G02Gn-C26320ppm10
G02Gn-C277.389AREA COUNT1
G02Gn-C27298ppm10
G02Gn-C285.48AREA COUNT1
G02Gn-C28221ppm10
G02Gn-C294.051AREA COUNT1
G02Gn-C29164ppm10
G02Gn-C305.282AREA COUNT1
G02Gn-C30213ppm10
G02Gn-C313.272AREA COUNT1
G02Gn-C31132ppm10
G02Gn-c322.526AREA COUNT1
G02Gn-c32102ppm10
G02Gn-C332.943AREA COUNT1
G02Gn-C33119ppm10
G02Gn-C343.403AREA COUNT1
G02Gn-C34137ppm10
G02Gn-C351.599AREA COUNT1
G02Gn-C3565ppm10
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C371.968AREA COUNT1
G02Gn-C3777ppm10
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane7.151AREA COUNT1
G02Gn-octane285ppm10
G02GNormal Alkane C928.422AREA COUNT1
G02GNormal Alkane C91135ppm10
G02Go-XYLENE6.485AREA COUNT1
G02Go-XYLENE258ppm10
G02Gp-XYLENE2.716AREA COUNT1
G02Gp-XYLENE110ppm10
G02GPENTANENDAREA COUNT1ND
G02GPENTANENDppm10ND
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane30.258AREA COUNT1
G02Gphytane1219ppm10
G02Gpristane49.429AREA COUNT1
G02Gpristane1989ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE3.213AREA COUNT1
G02GTOLUENE122ppm10
G02Gtrans-1,2-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,2-dimethylcyclopentaneNDppm10ND
G02Gtrans-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,3-dimethylcyclopentaneNDppm10ND

 Sample ID:   656927     Sample Date:  02/02/2024     Matrix:  WATER     Collection Point:  WellHead     Type:  OG     Lab:  

Sample Results for Sample # 656927 ID: 356004
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E170.1Sample Temperature70degrees F
E200.7ALUMINUM0mg/L
E200.7AMMONIA0mg/L
E200.7BARIUM103.1mg/L
E200.7CALCIUM533.53mg/L
E200.7IRON20.31mg/L
E200.7LEAD0mg/L
E200.7LITHIUM2.9mg/L
E200.7MAGNESIUM58.52mg/L
E200.7MANGANESE0.21mg/L
E200.7POTASSIUM41.43mg/L
E200.7SODIUM19058mg/L
E200.7STRONTIUM75.02mg/L
E200.7ZINC0.082mg/L
E200.8TOTAL DISSOLVED SOLIDS, CALCULATED LAB52313mg/L
E300.0ACETIC ACID0mg/L
E300.0BICARBONATE ALKALINITY as CACO3683.2mg/L as CaCO3
E300.0BORON13.68mg/L
E300.0BROMIDE0mg/L
E300.0CARBON DIOXIDE130mg/L
E300.0CARBONATE ALKALINITY AS CACO30mg/L as CaCO3
E300.0CHLORIDE30300mg/L
E300.0FLUORIDE0mg/L
E300.0HYDROGEN SULFIDE2.89mg/L
E300.0NITRATE0mg/L
E300.0PHOSPHATE0mg/L
E300.0SILICA (SiO2)0mg/L
E300.0SULFATE0mg/L
SM2510BRESISTIVITY16.63ohm/M
SM2510BSPECIFIC CONDUCTIVITY60149uS/cm
SM2710FSPECIFIC GRAVITY1.032RATIO_AIR
SM4500-H+ BPH, LAB6.68pH Units
SOPPRESSURE0.0266PSIG
SOPPRESSURE1.2668PSIG
SOPPRESSURE14.6959PSIG